IR aperture measurement at β*=40 cm

This note summarizes MD 307, performed on August 27 2015, during which we measured with beam the global apertures at 6.5 TeV with IR1 and IR5 squeezed to β* =40 cm and a half crossing angle of 205 rad. The measurement technique involved opening collimators in steps, while inducing beam losses at eac...

Descripción completa

Detalles Bibliográficos
Autores principales: Bruce, Roderik, Garcia Morales, Hector, Hermes, Pascal Dominik, Kwee-Hinzmann, Regina, Mereghetti, Alessio, Mirarchi, Daniele, Redaelli, Stefano, Salvachua Ferrando, Belen Maria, Skowronski, Piotr Krzysztof, Valentino, Gianluca, Valloni, Alessandra
Lenguaje:eng
Publicado: 2015
Materias:
Acceso en línea:http://cds.cern.ch/record/2093561
Descripción
Sumario:This note summarizes MD 307, performed on August 27 2015, during which we measured with beam the global apertures at 6.5 TeV with IR1 and IR5 squeezed to β* =40 cm and a half crossing angle of 205 rad. The measurement technique involved opening collimators in steps, while inducing beam losses at each step, until the main loss location moved from the collimators to the global bottleneck in one of the triplets. Measurements were performed in both beams and planes, and each measurement gave the minimum triplet aperture over IR1 and IR5. The results are in very good agreement with theoretical predictions. At the end of the MD, an asynchronous beam dump test was performed with all collimators moved in to so-called 2-σ retraction settings. This MD is one in a series meant to address various open points for the reach in β* in Run II.