Cargando…

CMS DT Upgrade The Sector Collector Relocation

The Sector Collector relocation is the first stage of the upgrade program for the Drift Tubes subdetector of the CMS experiment. It was accomplished during Long Shutdown 2013-2014, and consisted in the relocation of the second-level trigger and readout electronics from the experimental to the servic...

Descripción completa

Detalles Bibliográficos
Autores principales: Navarro Tobar, Alvaro, Fernandez Bedoya, Cristina
Lenguaje:eng
Publicado: 2015
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1748-0221/11/02/C02046
http://cds.cern.ch/record/2103730
_version_ 1780948766212227072
author Navarro Tobar, Alvaro
Fernandez Bedoya, Cristina
author_facet Navarro Tobar, Alvaro
Fernandez Bedoya, Cristina
author_sort Navarro Tobar, Alvaro
collection CERN
description The Sector Collector relocation is the first stage of the upgrade program for the Drift Tubes subdetector of the CMS experiment. It was accomplished during Long Shutdown 2013-2014, and consisted in the relocation of the second-level trigger and readout electronics from the experimental to the service cavern, relieving the environmental constraints and improving accessibility for maintenance and upgrade. Extending the electrical links would degrade reliability, so the information is converted to optical with a custom system capable of dealing with the DC-unbalanced data. Initially, present electronics are used, so optical-to-copper conversion has also been installed.
id cern-2103730
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2015
record_format invenio
spelling cern-21037302019-09-30T06:29:59Zdoi:10.1088/1748-0221/11/02/C02046http://cds.cern.ch/record/2103730engNavarro Tobar, AlvaroFernandez Bedoya, CristinaCMS DT Upgrade The Sector Collector RelocationDetectors and Experimental TechniquesThe Sector Collector relocation is the first stage of the upgrade program for the Drift Tubes subdetector of the CMS experiment. It was accomplished during Long Shutdown 2013-2014, and consisted in the relocation of the second-level trigger and readout electronics from the experimental to the service cavern, relieving the environmental constraints and improving accessibility for maintenance and upgrade. Extending the electrical links would degrade reliability, so the information is converted to optical with a custom system capable of dealing with the DC-unbalanced data. Initially, present electronics are used, so optical-to-copper conversion has also been installed.CMS-CR-2015-298oai:cds.cern.ch:21037302015-11-10
spellingShingle Detectors and Experimental Techniques
Navarro Tobar, Alvaro
Fernandez Bedoya, Cristina
CMS DT Upgrade The Sector Collector Relocation
title CMS DT Upgrade The Sector Collector Relocation
title_full CMS DT Upgrade The Sector Collector Relocation
title_fullStr CMS DT Upgrade The Sector Collector Relocation
title_full_unstemmed CMS DT Upgrade The Sector Collector Relocation
title_short CMS DT Upgrade The Sector Collector Relocation
title_sort cms dt upgrade the sector collector relocation
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1088/1748-0221/11/02/C02046
http://cds.cern.ch/record/2103730
work_keys_str_mv AT navarrotobaralvaro cmsdtupgradethesectorcollectorrelocation
AT fernandezbedoyacristina cmsdtupgradethesectorcollectorrelocation