Cargando…
CMS DT Upgrade The Sector Collector Relocation
The Sector Collector relocation is the first stage of the upgrade program for the Drift Tubes subdetector of the CMS experiment. It was accomplished during Long Shutdown 2013-2014, and consisted in the relocation of the second-level trigger and readout electronics from the experimental to the servic...
Autores principales: | , |
---|---|
Lenguaje: | eng |
Publicado: |
2015
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/1748-0221/11/02/C02046 http://cds.cern.ch/record/2103730 |
_version_ | 1780948766212227072 |
---|---|
author | Navarro Tobar, Alvaro Fernandez Bedoya, Cristina |
author_facet | Navarro Tobar, Alvaro Fernandez Bedoya, Cristina |
author_sort | Navarro Tobar, Alvaro |
collection | CERN |
description | The Sector Collector relocation is the first stage of the upgrade program for the Drift Tubes subdetector of the CMS experiment. It was accomplished during Long Shutdown 2013-2014, and consisted in the relocation of the second-level trigger and readout electronics from the experimental to the service cavern, relieving the environmental constraints and improving accessibility for maintenance and upgrade. Extending the electrical links would degrade reliability, so the information is converted to optical with a custom system capable of dealing with the DC-unbalanced data. Initially, present electronics are used, so optical-to-copper conversion has also been installed. |
id | cern-2103730 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2015 |
record_format | invenio |
spelling | cern-21037302019-09-30T06:29:59Zdoi:10.1088/1748-0221/11/02/C02046http://cds.cern.ch/record/2103730engNavarro Tobar, AlvaroFernandez Bedoya, CristinaCMS DT Upgrade The Sector Collector RelocationDetectors and Experimental TechniquesThe Sector Collector relocation is the first stage of the upgrade program for the Drift Tubes subdetector of the CMS experiment. It was accomplished during Long Shutdown 2013-2014, and consisted in the relocation of the second-level trigger and readout electronics from the experimental to the service cavern, relieving the environmental constraints and improving accessibility for maintenance and upgrade. Extending the electrical links would degrade reliability, so the information is converted to optical with a custom system capable of dealing with the DC-unbalanced data. Initially, present electronics are used, so optical-to-copper conversion has also been installed.CMS-CR-2015-298oai:cds.cern.ch:21037302015-11-10 |
spellingShingle | Detectors and Experimental Techniques Navarro Tobar, Alvaro Fernandez Bedoya, Cristina CMS DT Upgrade The Sector Collector Relocation |
title | CMS DT Upgrade The Sector Collector Relocation |
title_full | CMS DT Upgrade The Sector Collector Relocation |
title_fullStr | CMS DT Upgrade The Sector Collector Relocation |
title_full_unstemmed | CMS DT Upgrade The Sector Collector Relocation |
title_short | CMS DT Upgrade The Sector Collector Relocation |
title_sort | cms dt upgrade the sector collector relocation |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1088/1748-0221/11/02/C02046 http://cds.cern.ch/record/2103730 |
work_keys_str_mv | AT navarrotobaralvaro cmsdtupgradethesectorcollectorrelocation AT fernandezbedoyacristina cmsdtupgradethesectorcollectorrelocation |