Cargando…

The CMS Beam Halo Monitor Electronics

The CMS Beam Halo Monitor has been successfully installed in the CMS cavern in LHC Long Shutdown 1 for measuring the machine induced background for LHC Run II. The system is based on 40 detector units composed of synthetic quartz Cherenkov radiators coupled to fast photomultiplier tubes. The readout...

Descripción completa

Detalles Bibliográficos
Autores principales: Tosi, Nicolo, Dabrowski, A.E., Fabbri, F., Grassi, T., Hughes, E., Mans, J., Montanari, A., Orfanelli, S., Rusack, R., Torromeo, G., Stickland, D.P., Stifter, K.
Lenguaje:eng
Publicado: 2015
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1748-0221/11/02/C02039
http://cds.cern.ch/record/2103733
_version_ 1780948766845566976
author Tosi, Nicolo
Dabrowski, A.E.
Fabbri, F.
Grassi, T.
Hughes, E.
Mans, J.
Montanari, A.
Orfanelli, S.
Rusack, R.
Torromeo, G.
Stickland, D.P.
Stifter, K.
author_facet Tosi, Nicolo
Dabrowski, A.E.
Fabbri, F.
Grassi, T.
Hughes, E.
Mans, J.
Montanari, A.
Orfanelli, S.
Rusack, R.
Torromeo, G.
Stickland, D.P.
Stifter, K.
author_sort Tosi, Nicolo
collection CERN
description The CMS Beam Halo Monitor has been successfully installed in the CMS cavern in LHC Long Shutdown 1 for measuring the machine induced background for LHC Run II. The system is based on 40 detector units composed of synthetic quartz Cherenkov radiators coupled to fast photomultiplier tubes. The readout electronics chain uses many components developed for the Phase 1 upgrade to the CMS Hadronic Calorimeter electronics, with dedicated firmware and readout adapted to the beam monitoring requirements. The PMT signal is digitized by a charge integrating ASIC (QIE10), providing both the signal rise time, with few ns resolution, and the charge integrated over one bunch crossing. The backend electronics uses microTCA technology and receives data via a high-speed 5 Gbps asynchronous link. It records histograms with sub-bunch crossing timing resolution and is readout by IPbus using the newly designed CMS data acquisition for non-event based data. The data is processed in real time and published to CMS and the LHC, providing online feedback on the beam quality. A dedicated calibration monitoring system has been designed to generate short triggered pulses of light to monitor the efficiency of the system. The electronics has been in operation since the first LHC beams of Run II and has served as the first demonstration of the new QIE10, Igloo2 and high-speed 5 Gbps with LHC data. This paper presents the Beam Halo Monitor and the performance of the electronics thus far in Run II.
id cern-2103733
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2015
record_format invenio
spelling cern-21037332022-08-10T12:39:08Zdoi:10.1088/1748-0221/11/02/C02039http://cds.cern.ch/record/2103733engTosi, NicoloDabrowski, A.E.Fabbri, F.Grassi, T.Hughes, E.Mans, J.Montanari, A.Orfanelli, S.Rusack, R.Torromeo, G.Stickland, D.P.Stifter, K.The CMS Beam Halo Monitor ElectronicsDetectors and Experimental TechniquesThe CMS Beam Halo Monitor has been successfully installed in the CMS cavern in LHC Long Shutdown 1 for measuring the machine induced background for LHC Run II. The system is based on 40 detector units composed of synthetic quartz Cherenkov radiators coupled to fast photomultiplier tubes. The readout electronics chain uses many components developed for the Phase 1 upgrade to the CMS Hadronic Calorimeter electronics, with dedicated firmware and readout adapted to the beam monitoring requirements. The PMT signal is digitized by a charge integrating ASIC (QIE10), providing both the signal rise time, with few ns resolution, and the charge integrated over one bunch crossing. The backend electronics uses microTCA technology and receives data via a high-speed 5 Gbps asynchronous link. It records histograms with sub-bunch crossing timing resolution and is readout by IPbus using the newly designed CMS data acquisition for non-event based data. The data is processed in real time and published to CMS and the LHC, providing online feedback on the beam quality. A dedicated calibration monitoring system has been designed to generate short triggered pulses of light to monitor the efficiency of the system. The electronics has been in operation since the first LHC beams of Run II and has served as the first demonstration of the new QIE10, Igloo2 and high-speed 5 Gbps with LHC data. This paper presents the Beam Halo Monitor and the performance of the electronics thus far in Run II.CMS-CR-2015-303oai:cds.cern.ch:21037332015-11-13
spellingShingle Detectors and Experimental Techniques
Tosi, Nicolo
Dabrowski, A.E.
Fabbri, F.
Grassi, T.
Hughes, E.
Mans, J.
Montanari, A.
Orfanelli, S.
Rusack, R.
Torromeo, G.
Stickland, D.P.
Stifter, K.
The CMS Beam Halo Monitor Electronics
title The CMS Beam Halo Monitor Electronics
title_full The CMS Beam Halo Monitor Electronics
title_fullStr The CMS Beam Halo Monitor Electronics
title_full_unstemmed The CMS Beam Halo Monitor Electronics
title_short The CMS Beam Halo Monitor Electronics
title_sort cms beam halo monitor electronics
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1088/1748-0221/11/02/C02039
http://cds.cern.ch/record/2103733
work_keys_str_mv AT tosinicolo thecmsbeamhalomonitorelectronics
AT dabrowskiae thecmsbeamhalomonitorelectronics
AT fabbrif thecmsbeamhalomonitorelectronics
AT grassit thecmsbeamhalomonitorelectronics
AT hughese thecmsbeamhalomonitorelectronics
AT mansj thecmsbeamhalomonitorelectronics
AT montanaria thecmsbeamhalomonitorelectronics
AT orfanellis thecmsbeamhalomonitorelectronics
AT rusackr thecmsbeamhalomonitorelectronics
AT torromeog thecmsbeamhalomonitorelectronics
AT sticklanddp thecmsbeamhalomonitorelectronics
AT stifterk thecmsbeamhalomonitorelectronics
AT tosinicolo cmsbeamhalomonitorelectronics
AT dabrowskiae cmsbeamhalomonitorelectronics
AT fabbrif cmsbeamhalomonitorelectronics
AT grassit cmsbeamhalomonitorelectronics
AT hughese cmsbeamhalomonitorelectronics
AT mansj cmsbeamhalomonitorelectronics
AT montanaria cmsbeamhalomonitorelectronics
AT orfanellis cmsbeamhalomonitorelectronics
AT rusackr cmsbeamhalomonitorelectronics
AT torromeog cmsbeamhalomonitorelectronics
AT sticklanddp cmsbeamhalomonitorelectronics
AT stifterk cmsbeamhalomonitorelectronics