Cargando…
Measurement of charged particle yields from PMMA irradiated by a 220 MeV/u12Cbeam
The radiation used in hadrontherapy treatments interacts with the patient body producing secondary particles, either neutral or charged, that can be used for dose and Bragg peak monitoring and to provide a fast feedback on the treatment plans. Recent results obtained from the authors on simplified s...
Autores principales: | , , , , , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2014
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/0031-9155/59/7/1857 http://cds.cern.ch/record/2114745 |
_version_ | 1780949152811712512 |
---|---|
author | Piersanti, L Bellini, F Bini, FU. Rome La Sapienza (main) Collamati, F De Lucia, E Durante, M Faccini, R Ferroni, F Fiore, S Iarocci, E La Tessa, C Marafini, M Mattei, I Patera, V Ortega, P G Sarti, A Schuy, C Sciubba, A Vanstalle, M Voena, C |
author_facet | Piersanti, L Bellini, F Bini, FU. Rome La Sapienza (main) Collamati, F De Lucia, E Durante, M Faccini, R Ferroni, F Fiore, S Iarocci, E La Tessa, C Marafini, M Mattei, I Patera, V Ortega, P G Sarti, A Schuy, C Sciubba, A Vanstalle, M Voena, C |
author_sort | Piersanti, L |
collection | CERN |
description | The radiation used in hadrontherapy treatments interacts with the patient body producing secondary particles, either neutral or charged, that can be used for dose and Bragg peak monitoring and to provide a fast feedback on the treatment plans. Recent results obtained from the authors on simplified setups (mono-energetic primary beams interacting with homogeneous tissue like target) have already indicated the correlation that exists between the flux of these secondaries coming from the target (e.g. protons and photons) and the position of the primary beam Bragg peak. In this paper, the measurements of charged particle fluxes produced by the interaction of a 220 MeV/u carbon ion beam at GSI, Darmstadt, with a polymethyl methacrylate target are reported. The emission region of protons (p), deuterons (d) and tritons (t) has been characterized using a drift chamber while the particle time-of-flight, used to compute the kinetic energy spectra, was measured with a LYSO scintillator.The energy released in the LYSO crystal was used for particle identification purposes. The measurements were repeated with the setup at 60 degrees and 90 degrees with respect to the primary beam direction. The accuracy on the fragments emission profile reconstruction and its relationship with the Bragg peak position have been studied. Based on the acquired experimental evidence, a method to monitor the dose profile and the position of the Bragg peak inside the target is proposed. |
id | cern-2114745 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2014 |
record_format | invenio |
spelling | cern-21147452019-09-30T06:29:59Zdoi:10.1088/0031-9155/59/7/1857http://cds.cern.ch/record/2114745engPiersanti, LBellini, FBini, FU. Rome La Sapienza (main)Collamati, FDe Lucia, EDurante, MFaccini, RFerroni, FFiore, SIarocci, ELa Tessa, CMarafini, MMattei, IPatera, VOrtega, P GSarti, ASchuy, CSciubba, AVanstalle, MVoena, CMeasurement of charged particle yields from PMMA irradiated by a 220 MeV/u12CbeamXXThe radiation used in hadrontherapy treatments interacts with the patient body producing secondary particles, either neutral or charged, that can be used for dose and Bragg peak monitoring and to provide a fast feedback on the treatment plans. Recent results obtained from the authors on simplified setups (mono-energetic primary beams interacting with homogeneous tissue like target) have already indicated the correlation that exists between the flux of these secondaries coming from the target (e.g. protons and photons) and the position of the primary beam Bragg peak. In this paper, the measurements of charged particle fluxes produced by the interaction of a 220 MeV/u carbon ion beam at GSI, Darmstadt, with a polymethyl methacrylate target are reported. The emission region of protons (p), deuterons (d) and tritons (t) has been characterized using a drift chamber while the particle time-of-flight, used to compute the kinetic energy spectra, was measured with a LYSO scintillator.The energy released in the LYSO crystal was used for particle identification purposes. The measurements were repeated with the setup at 60 degrees and 90 degrees with respect to the primary beam direction. The accuracy on the fragments emission profile reconstruction and its relationship with the Bragg peak position have been studied. Based on the acquired experimental evidence, a method to monitor the dose profile and the position of the Bragg peak inside the target is proposed.oai:cds.cern.ch:21147452014 |
spellingShingle | XX Piersanti, L Bellini, F Bini, FU. Rome La Sapienza (main) Collamati, F De Lucia, E Durante, M Faccini, R Ferroni, F Fiore, S Iarocci, E La Tessa, C Marafini, M Mattei, I Patera, V Ortega, P G Sarti, A Schuy, C Sciubba, A Vanstalle, M Voena, C Measurement of charged particle yields from PMMA irradiated by a 220 MeV/u12Cbeam |
title | Measurement of charged particle yields from PMMA irradiated by a 220 MeV/u12Cbeam |
title_full | Measurement of charged particle yields from PMMA irradiated by a 220 MeV/u12Cbeam |
title_fullStr | Measurement of charged particle yields from PMMA irradiated by a 220 MeV/u12Cbeam |
title_full_unstemmed | Measurement of charged particle yields from PMMA irradiated by a 220 MeV/u12Cbeam |
title_short | Measurement of charged particle yields from PMMA irradiated by a 220 MeV/u12Cbeam |
title_sort | measurement of charged particle yields from pmma irradiated by a 220 mev/u12cbeam |
topic | XX |
url | https://dx.doi.org/10.1088/0031-9155/59/7/1857 http://cds.cern.ch/record/2114745 |
work_keys_str_mv | AT piersantil measurementofchargedparticleyieldsfrompmmairradiatedbya220mevu12cbeam AT bellinif measurementofchargedparticleyieldsfrompmmairradiatedbya220mevu12cbeam AT binifuromelasapienzamain measurementofchargedparticleyieldsfrompmmairradiatedbya220mevu12cbeam AT collamatif measurementofchargedparticleyieldsfrompmmairradiatedbya220mevu12cbeam AT deluciae measurementofchargedparticleyieldsfrompmmairradiatedbya220mevu12cbeam AT durantem measurementofchargedparticleyieldsfrompmmairradiatedbya220mevu12cbeam AT faccinir measurementofchargedparticleyieldsfrompmmairradiatedbya220mevu12cbeam AT ferronif measurementofchargedparticleyieldsfrompmmairradiatedbya220mevu12cbeam AT fiores measurementofchargedparticleyieldsfrompmmairradiatedbya220mevu12cbeam AT iaroccie measurementofchargedparticleyieldsfrompmmairradiatedbya220mevu12cbeam AT latessac measurementofchargedparticleyieldsfrompmmairradiatedbya220mevu12cbeam AT marafinim measurementofchargedparticleyieldsfrompmmairradiatedbya220mevu12cbeam AT matteii measurementofchargedparticleyieldsfrompmmairradiatedbya220mevu12cbeam AT paterav measurementofchargedparticleyieldsfrompmmairradiatedbya220mevu12cbeam AT ortegapg measurementofchargedparticleyieldsfrompmmairradiatedbya220mevu12cbeam AT sartia measurementofchargedparticleyieldsfrompmmairradiatedbya220mevu12cbeam AT schuyc measurementofchargedparticleyieldsfrompmmairradiatedbya220mevu12cbeam AT sciubbaa measurementofchargedparticleyieldsfrompmmairradiatedbya220mevu12cbeam AT vanstallem measurementofchargedparticleyieldsfrompmmairradiatedbya220mevu12cbeam AT voenac measurementofchargedparticleyieldsfrompmmairradiatedbya220mevu12cbeam |