Capacitive Gap Distance Control in Pin-Plane electrode DC Spark Systems at CERN
Capacitive inter-electrode gap distance measurement and control has been implemented into DC Spark System II, used by the DC Spark Study to conduct vacuum electrical breakdown experiments as a complement to breakdown experiments in RF accelerating structures. The implemented system is described, alo...