MD 349: Impedance Localization with AC-dipole

The purpose of this MD is to measure the distribution of the transverse impedance of the LHC by observing the phase advance variation with intensity between the machine BPMs. Four injected bunches with different intensities are excited with an AC dipole and the turn by turn data is acquired from the...

Descripción completa

Detalles Bibliográficos
Autores principales: Biancacci, Nicolo, Carver, Lee Robert, Metral, Elias, Salvant, Benoit, Papotti, Giulia, Persson, Tobias Hakan Bjorn, Tomas Garcia, Rogelio
Lenguaje:eng
Publicado: 2016
Materias:
Acceso en línea:http://cds.cern.ch/record/2119918
_version_ 1780949282743910400
author Biancacci, Nicolo
Carver, Lee Robert
Metral, Elias
Salvant, Benoit
Papotti, Giulia
Persson, Tobias Hakan Bjorn
Tomas Garcia, Rogelio
author_facet Biancacci, Nicolo
Carver, Lee Robert
Metral, Elias
Salvant, Benoit
Papotti, Giulia
Persson, Tobias Hakan Bjorn
Tomas Garcia, Rogelio
author_sort Biancacci, Nicolo
collection CERN
description The purpose of this MD is to measure the distribution of the transverse impedance of the LHC by observing the phase advance variation with intensity between the machine BPMs. Four injected bunches with different intensities are excited with an AC dipole and the turn by turn data is acquired from the BPM system. Through post-processing analysis the phase variation along the machine is depicted and, from this information, first conclusions of the impedance distribution can be drawn.
id cern-2119918
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling cern-21199182019-09-30T06:29:59Zhttp://cds.cern.ch/record/2119918engBiancacci, NicoloCarver, Lee RobertMetral, EliasSalvant, BenoitPapotti, GiuliaPersson, Tobias Hakan BjornTomas Garcia, RogelioMD 349: Impedance Localization with AC-dipoleAccelerators and Storage RingsThe purpose of this MD is to measure the distribution of the transverse impedance of the LHC by observing the phase advance variation with intensity between the machine BPMs. Four injected bunches with different intensities are excited with an AC dipole and the turn by turn data is acquired from the BPM system. Through post-processing analysis the phase variation along the machine is depicted and, from this information, first conclusions of the impedance distribution can be drawn.CERN-ACC-NOTE-2016-0003oai:cds.cern.ch:21199182016-01-05
spellingShingle Accelerators and Storage Rings
Biancacci, Nicolo
Carver, Lee Robert
Metral, Elias
Salvant, Benoit
Papotti, Giulia
Persson, Tobias Hakan Bjorn
Tomas Garcia, Rogelio
MD 349: Impedance Localization with AC-dipole
title MD 349: Impedance Localization with AC-dipole
title_full MD 349: Impedance Localization with AC-dipole
title_fullStr MD 349: Impedance Localization with AC-dipole
title_full_unstemmed MD 349: Impedance Localization with AC-dipole
title_short MD 349: Impedance Localization with AC-dipole
title_sort md 349: impedance localization with ac-dipole
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/2119918
work_keys_str_mv AT biancaccinicolo md349impedancelocalizationwithacdipole
AT carverleerobert md349impedancelocalizationwithacdipole
AT metralelias md349impedancelocalizationwithacdipole
AT salvantbenoit md349impedancelocalizationwithacdipole
AT papottigiulia md349impedancelocalizationwithacdipole
AT perssontobiashakanbjorn md349impedancelocalizationwithacdipole
AT tomasgarciarogelio md349impedancelocalizationwithacdipole