Cargando…

Comparison on the production of radionuclides in 1.4 GeV proton irradiated LBE targets of different thickness

This is the first report on the inventory of radionuclides produced in 1.4 GeV proton induced reaction on Lead-Bismuth Eutectic (LBE) targets. LBE targets of 6 mm diameter and 1 to 8 mm lengths were irradiated with 1.4 GeV protons. The radionuclides ranging from Be-7 (53.12 days) to Po-207 (5.8 h) w...

Descripción completa

Detalles Bibliográficos
Autores principales: Maiti, Moumita, Ghosh, Kaustab, Mendonça, Tania M, Stora, Thierry, Lahiri, Susanta
Lenguaje:eng
Publicado: 2014
Materias:
XX
Acceso en línea:https://dx.doi.org/10.1007/s10967-014-3636-6
http://cds.cern.ch/record/2120649
_version_ 1780949331147227136
author Maiti, Moumita
Ghosh, Kaustab
Mendonça, Tania M
Stora, Thierry
Lahiri, Susanta
author_facet Maiti, Moumita
Ghosh, Kaustab
Mendonça, Tania M
Stora, Thierry
Lahiri, Susanta
author_sort Maiti, Moumita
collection CERN
description This is the first report on the inventory of radionuclides produced in 1.4 GeV proton induced reaction on Lead-Bismuth Eutectic (LBE) targets. LBE targets of 6 mm diameter and 1 to 8 mm lengths were irradiated with 1.4 GeV protons. The radionuclides ranging from Be-7 (53.12 days) to Po-207 (5.8 h) were identified in the samples with the help of time resolved gamma-ray spectroscopy. However, there is no signature of formation of At radioisotopes, which can be produced by the interaction of secondary particles, typical for thick targets.
id cern-2120649
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2014
record_format invenio
spelling cern-21206492019-09-30T06:29:59Zdoi:10.1007/s10967-014-3636-6http://cds.cern.ch/record/2120649engMaiti, MoumitaGhosh, KaustabMendonça, Tania MStora, ThierryLahiri, SusantaComparison on the production of radionuclides in 1.4 GeV proton irradiated LBE targets of different thicknessXXThis is the first report on the inventory of radionuclides produced in 1.4 GeV proton induced reaction on Lead-Bismuth Eutectic (LBE) targets. LBE targets of 6 mm diameter and 1 to 8 mm lengths were irradiated with 1.4 GeV protons. The radionuclides ranging from Be-7 (53.12 days) to Po-207 (5.8 h) were identified in the samples with the help of time resolved gamma-ray spectroscopy. However, there is no signature of formation of At radioisotopes, which can be produced by the interaction of secondary particles, typical for thick targets.oai:cds.cern.ch:21206492014
spellingShingle XX
Maiti, Moumita
Ghosh, Kaustab
Mendonça, Tania M
Stora, Thierry
Lahiri, Susanta
Comparison on the production of radionuclides in 1.4 GeV proton irradiated LBE targets of different thickness
title Comparison on the production of radionuclides in 1.4 GeV proton irradiated LBE targets of different thickness
title_full Comparison on the production of radionuclides in 1.4 GeV proton irradiated LBE targets of different thickness
title_fullStr Comparison on the production of radionuclides in 1.4 GeV proton irradiated LBE targets of different thickness
title_full_unstemmed Comparison on the production of radionuclides in 1.4 GeV proton irradiated LBE targets of different thickness
title_short Comparison on the production of radionuclides in 1.4 GeV proton irradiated LBE targets of different thickness
title_sort comparison on the production of radionuclides in 1.4 gev proton irradiated lbe targets of different thickness
topic XX
url https://dx.doi.org/10.1007/s10967-014-3636-6
http://cds.cern.ch/record/2120649
work_keys_str_mv AT maitimoumita comparisonontheproductionofradionuclidesin14gevprotonirradiatedlbetargetsofdifferentthickness
AT ghoshkaustab comparisonontheproductionofradionuclidesin14gevprotonirradiatedlbetargetsofdifferentthickness
AT mendoncataniam comparisonontheproductionofradionuclidesin14gevprotonirradiatedlbetargetsofdifferentthickness
AT storathierry comparisonontheproductionofradionuclidesin14gevprotonirradiatedlbetargetsofdifferentthickness
AT lahirisusanta comparisonontheproductionofradionuclidesin14gevprotonirradiatedlbetargetsofdifferentthickness