Overview of the ICRP/ICRU adult reference computational phantoms and dose conversion coefficients for external idealised exposures

This paper reviews the ICRP Publications 110 and 116 describing the reference computational phantoms and dose conversion coefficients for external exposures. The International Commission on Radiological Protection (ICRP) in its 2007 Recommendations made several revisions to the methods of calculatio...

Descripción completa

Detalles Bibliográficos
Autores principales: Endo, A, Petoussi-Henss, N, Zankl, M, Bolch, W E, Eckerman, K F, Hertel, N E, Hunt, J G, Pelliccioni, M, Schlattl, H, Menzel, H-G
Lenguaje:eng
Publicado: 2014
Materias:
XX
Acceso en línea:https://dx.doi.org/10.1093/rpd/nct304
http://cds.cern.ch/record/2124590
_version_ 1780949567625232384
author Endo, A
Petoussi-Henss, N
Zankl, M
Bolch, W E
Eckerman, K F
Hertel, N E
Hunt, J G
Pelliccioni, M
Schlattl, H
Menzel, H-G
author_facet Endo, A
Petoussi-Henss, N
Zankl, M
Bolch, W E
Eckerman, K F
Hertel, N E
Hunt, J G
Pelliccioni, M
Schlattl, H
Menzel, H-G
author_sort Endo, A
collection CERN
description This paper reviews the ICRP Publications 110 and 116 describing the reference computational phantoms and dose conversion coefficients for external exposures. The International Commission on Radiological Protection (ICRP) in its 2007 Recommendations made several revisions to the methods of calculation of the protection quantities. In order to implement these recommendations, the DOCAL task group of the ICRP developed computational phantoms representing the reference adult male and female and then calculated a set of dose conversion coefficients for various types of idealised external exposures. This paper focuses on the dose conversion coefficients for neutrons and investigates their relationship with the conversion coefficients of the protection and operational quantities of ICRP Publication 74. Contributing factors to the differences between these sets of conversion coefficients are discussed in terms of the changes in phantoms employed and the radiation and tissue weighting factors.
id cern-2124590
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2014
record_format invenio
spelling cern-21245902019-09-30T06:29:59Zdoi:10.1093/rpd/nct304http://cds.cern.ch/record/2124590engEndo, APetoussi-Henss, NZankl, MBolch, W EEckerman, K FHertel, N EHunt, J GPelliccioni, MSchlattl, HMenzel, H-GOverview of the ICRP/ICRU adult reference computational phantoms and dose conversion coefficients for external idealised exposuresXXThis paper reviews the ICRP Publications 110 and 116 describing the reference computational phantoms and dose conversion coefficients for external exposures. The International Commission on Radiological Protection (ICRP) in its 2007 Recommendations made several revisions to the methods of calculation of the protection quantities. In order to implement these recommendations, the DOCAL task group of the ICRP developed computational phantoms representing the reference adult male and female and then calculated a set of dose conversion coefficients for various types of idealised external exposures. This paper focuses on the dose conversion coefficients for neutrons and investigates their relationship with the conversion coefficients of the protection and operational quantities of ICRP Publication 74. Contributing factors to the differences between these sets of conversion coefficients are discussed in terms of the changes in phantoms employed and the radiation and tissue weighting factors.oai:cds.cern.ch:21245902014
spellingShingle XX
Endo, A
Petoussi-Henss, N
Zankl, M
Bolch, W E
Eckerman, K F
Hertel, N E
Hunt, J G
Pelliccioni, M
Schlattl, H
Menzel, H-G
Overview of the ICRP/ICRU adult reference computational phantoms and dose conversion coefficients for external idealised exposures
title Overview of the ICRP/ICRU adult reference computational phantoms and dose conversion coefficients for external idealised exposures
title_full Overview of the ICRP/ICRU adult reference computational phantoms and dose conversion coefficients for external idealised exposures
title_fullStr Overview of the ICRP/ICRU adult reference computational phantoms and dose conversion coefficients for external idealised exposures
title_full_unstemmed Overview of the ICRP/ICRU adult reference computational phantoms and dose conversion coefficients for external idealised exposures
title_short Overview of the ICRP/ICRU adult reference computational phantoms and dose conversion coefficients for external idealised exposures
title_sort overview of the icrp/icru adult reference computational phantoms and dose conversion coefficients for external idealised exposures
topic XX
url https://dx.doi.org/10.1093/rpd/nct304
http://cds.cern.ch/record/2124590
work_keys_str_mv AT endoa overviewoftheicrpicruadultreferencecomputationalphantomsanddoseconversioncoefficientsforexternalidealisedexposures
AT petoussihenssn overviewoftheicrpicruadultreferencecomputationalphantomsanddoseconversioncoefficientsforexternalidealisedexposures
AT zanklm overviewoftheicrpicruadultreferencecomputationalphantomsanddoseconversioncoefficientsforexternalidealisedexposures
AT bolchwe overviewoftheicrpicruadultreferencecomputationalphantomsanddoseconversioncoefficientsforexternalidealisedexposures
AT eckermankf overviewoftheicrpicruadultreferencecomputationalphantomsanddoseconversioncoefficientsforexternalidealisedexposures
AT hertelne overviewoftheicrpicruadultreferencecomputationalphantomsanddoseconversioncoefficientsforexternalidealisedexposures
AT huntjg overviewoftheicrpicruadultreferencecomputationalphantomsanddoseconversioncoefficientsforexternalidealisedexposures
AT pelliccionim overviewoftheicrpicruadultreferencecomputationalphantomsanddoseconversioncoefficientsforexternalidealisedexposures
AT schlattlh overviewoftheicrpicruadultreferencecomputationalphantomsanddoseconversioncoefficientsforexternalidealisedexposures
AT menzelhg overviewoftheicrpicruadultreferencecomputationalphantomsanddoseconversioncoefficientsforexternalidealisedexposures