Cargando…
Beam Instrumentation and Diagnostics for the LHC Upgrade
The extensive array of beam instrumentation with which the LHC is equipped, has played a major role in its commissioning, rapid intensity ramp-up and safe and reliable operation. High Luminosity LHC (HL-LHC) brings with it a number of new challenges in terms of beam instrumentation that will be disc...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2015
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1142/9789814675475_0020 http://cds.cern.ch/record/2131858 |
_version_ | 1780949826281668608 |
---|---|
author | Bravin, E Dehning, B Jones, R Lefevre, T |
author_facet | Bravin, E Dehning, B Jones, R Lefevre, T |
author_sort | Bravin, E |
collection | CERN |
description | The extensive array of beam instrumentation with which the LHC is equipped, has played a major role in its commissioning, rapid intensity ramp-up and safe and reliable operation. High Luminosity LHC (HL-LHC) brings with it a number of new challenges in terms of beam instrumentation that will be discussed in this chapter. The beam loss system will need significant upgrades in order to be able to cope with the demands of HL-LHC, with cryogenic beam loss monitors under investigation for deployment in the new inner triplet magnets to distinguish between primary beam losses and collision debris. Radiation tolerant integrated circuits are also being developed to allow the front-end electronics to sit much closer to the detector. Upgrades to other existing systems are also envisaged; including the beam position measurement system in the interaction regions and the addition of a halo measurement capability to synchrotron light diagnostics. Additionally, several new diagnostic systems are under investigation, such as very high bandwidth pick-ups and a streak camera installation, both able to perform intra-bunch measurements of transverse position on a turn by turn basis. |
id | cern-2131858 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2015 |
record_format | invenio |
spelling | cern-21318582022-08-10T12:56:18Zdoi:10.1142/9789814675475_0020http://cds.cern.ch/record/2131858engBravin, EDehning, BJones, RLefevre, TBeam Instrumentation and Diagnostics for the LHC UpgradeAccelerators and Storage RingsThe extensive array of beam instrumentation with which the LHC is equipped, has played a major role in its commissioning, rapid intensity ramp-up and safe and reliable operation. High Luminosity LHC (HL-LHC) brings with it a number of new challenges in terms of beam instrumentation that will be discussed in this chapter. The beam loss system will need significant upgrades in order to be able to cope with the demands of HL-LHC, with cryogenic beam loss monitors under investigation for deployment in the new inner triplet magnets to distinguish between primary beam losses and collision debris. Radiation tolerant integrated circuits are also being developed to allow the front-end electronics to sit much closer to the detector. Upgrades to other existing systems are also envisaged; including the beam position measurement system in the interaction regions and the addition of a halo measurement capability to synchrotron light diagnostics. Additionally, several new diagnostic systems are under investigation, such as very high bandwidth pick-ups and a streak camera installation, both able to perform intra-bunch measurements of transverse position on a turn by turn basis.oai:cds.cern.ch:21318582015 |
spellingShingle | Accelerators and Storage Rings Bravin, E Dehning, B Jones, R Lefevre, T Beam Instrumentation and Diagnostics for the LHC Upgrade |
title | Beam Instrumentation and Diagnostics for the LHC Upgrade |
title_full | Beam Instrumentation and Diagnostics for the LHC Upgrade |
title_fullStr | Beam Instrumentation and Diagnostics for the LHC Upgrade |
title_full_unstemmed | Beam Instrumentation and Diagnostics for the LHC Upgrade |
title_short | Beam Instrumentation and Diagnostics for the LHC Upgrade |
title_sort | beam instrumentation and diagnostics for the lhc upgrade |
topic | Accelerators and Storage Rings |
url | https://dx.doi.org/10.1142/9789814675475_0020 http://cds.cern.ch/record/2131858 |
work_keys_str_mv | AT bravine beaminstrumentationanddiagnosticsforthelhcupgrade AT dehningb beaminstrumentationanddiagnosticsforthelhcupgrade AT jonesr beaminstrumentationanddiagnosticsforthelhcupgrade AT lefevret beaminstrumentationanddiagnosticsforthelhcupgrade |