Cargando…
Instrument intercomparison in the high-energy mixed field at the CERN-EU reference field (CERF) facility
This paper discusses an intercomparison campaign performed in the mixed radiation field at the CERN-EU (CERF) reference field facility. Various instruments were employed: conventional and extended-range rem counters including a novel instrument called LUPIN, a bubble detector using an active countin...
Autores principales: | , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2014
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1093/rpd/nct312 http://cds.cern.ch/record/2138285 |
_version_ | 1780950049647230976 |
---|---|
author | Caresana, Marco Helmecke, Manuela Manessi, Giacomo Ott, Klaus Scherpelz, Robert Silari, Marco |
author_facet | Caresana, Marco Helmecke, Manuela Manessi, Giacomo Ott, Klaus Scherpelz, Robert Silari, Marco |
author_sort | Caresana, Marco |
collection | CERN |
description | This paper discusses an intercomparison campaign performed in the mixed radiation field at the CERN-EU (CERF) reference field facility. Various instruments were employed: conventional and extended-range rem counters including a novel instrument called LUPIN, a bubble detector using an active counting system (ABC 1260) and two tissue-equivalent proportional counters (TEPCs). The results show that the extended range instruments agree well within their uncertainties and within 1σ with the H*(10) FLUKA value. The conventional rem counters are in good agreement within their uncertainties and underestimate H*(10) as measured by the extended range instruments and as predicted by FLUKA. The TEPCs slightly overestimate the FLUKA value but they are anyhow consistent with it when taking the comparatively large total uncertainties into account, and indicate that the non-neutron part of the stray field accounts for ∼30 % of the total H*(10). |
id | cern-2138285 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2014 |
record_format | invenio |
spelling | cern-21382852019-09-30T06:29:59Zdoi:10.1093/rpd/nct312http://cds.cern.ch/record/2138285engCaresana, MarcoHelmecke, ManuelaManessi, GiacomoOtt, KlausScherpelz, RobertSilari, MarcoInstrument intercomparison in the high-energy mixed field at the CERN-EU reference field (CERF) facilityHealth Physics and Radiation EffectsThis paper discusses an intercomparison campaign performed in the mixed radiation field at the CERN-EU (CERF) reference field facility. Various instruments were employed: conventional and extended-range rem counters including a novel instrument called LUPIN, a bubble detector using an active counting system (ABC 1260) and two tissue-equivalent proportional counters (TEPCs). The results show that the extended range instruments agree well within their uncertainties and within 1σ with the H*(10) FLUKA value. The conventional rem counters are in good agreement within their uncertainties and underestimate H*(10) as measured by the extended range instruments and as predicted by FLUKA. The TEPCs slightly overestimate the FLUKA value but they are anyhow consistent with it when taking the comparatively large total uncertainties into account, and indicate that the non-neutron part of the stray field accounts for ∼30 % of the total H*(10).oai:cds.cern.ch:21382852014 |
spellingShingle | Health Physics and Radiation Effects Caresana, Marco Helmecke, Manuela Manessi, Giacomo Ott, Klaus Scherpelz, Robert Silari, Marco Instrument intercomparison in the high-energy mixed field at the CERN-EU reference field (CERF) facility |
title | Instrument intercomparison in the high-energy mixed field at the CERN-EU reference field (CERF) facility |
title_full | Instrument intercomparison in the high-energy mixed field at the CERN-EU reference field (CERF) facility |
title_fullStr | Instrument intercomparison in the high-energy mixed field at the CERN-EU reference field (CERF) facility |
title_full_unstemmed | Instrument intercomparison in the high-energy mixed field at the CERN-EU reference field (CERF) facility |
title_short | Instrument intercomparison in the high-energy mixed field at the CERN-EU reference field (CERF) facility |
title_sort | instrument intercomparison in the high-energy mixed field at the cern-eu reference field (cerf) facility |
topic | Health Physics and Radiation Effects |
url | https://dx.doi.org/10.1093/rpd/nct312 http://cds.cern.ch/record/2138285 |
work_keys_str_mv | AT caresanamarco instrumentintercomparisoninthehighenergymixedfieldatthecerneureferencefieldcerffacility AT helmeckemanuela instrumentintercomparisoninthehighenergymixedfieldatthecerneureferencefieldcerffacility AT instrumentintercomparisoninthehighenergymixedfieldatthecerneureferencefieldcerffacility AT manessigiacomo instrumentintercomparisoninthehighenergymixedfieldatthecerneureferencefieldcerffacility AT ottklaus instrumentintercomparisoninthehighenergymixedfieldatthecerneureferencefieldcerffacility AT scherpelzrobert instrumentintercomparisoninthehighenergymixedfieldatthecerneureferencefieldcerffacility AT silarimarco instrumentintercomparisoninthehighenergymixedfieldatthecerneureferencefieldcerffacility |