The strict requirements in terms of material budget for the inner region of the CLIC detector concept require the use of a dry gas for the cooling of the respective sensors. This, in conjunction with the compactness of the inner volumes, poses several challenges for the design of a cooling system th...
Autores principales: | , , |
---|---|
Lenguaje: | eng |
Publicado: |
2016
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2138963 |
_version_ | 1780950065728192512 |
---|---|
author | Duarte Ramos, Fernando Klempt, Wolfgang Nuiry, Francois-Xavier |
author_facet | Duarte Ramos, Fernando Klempt, Wolfgang Nuiry, Francois-Xavier |
author_sort | Duarte Ramos, Fernando |
collection | CERN |
description | The strict requirements in terms of material budget for the inner region of the CLIC detector concept require the use of a dry gas for the cooling of the respective sensors. This, in conjunction with the compactness of the inner volumes, poses several challenges for the design of a cooling system that is able to fulfil the required detector specifications. This note summarizes the results obtained from experimental tests on the air cooling of the CLIC vertex detector as well as their comparison with the corresponding computational fluid dynamics simulations. |
id | cern-2138963 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2016 |
record_format | invenio |
spelling | cern-21389632019-09-30T06:29:59Zhttp://cds.cern.ch/record/2138963engDuarte Ramos, FernandoKlempt, WolfgangNuiry, Francois-XavierExperimental tests on the air cooling of the CLIC vertex detectorParticle Physics - ExperimentThe strict requirements in terms of material budget for the inner region of the CLIC detector concept require the use of a dry gas for the cooling of the respective sensors. This, in conjunction with the compactness of the inner volumes, poses several challenges for the design of a cooling system that is able to fulfil the required detector specifications. This note summarizes the results obtained from experimental tests on the air cooling of the CLIC vertex detector as well as their comparison with the corresponding computational fluid dynamics simulations.CLICdp-Note-2016-002oai:cds.cern.ch:21389632016 |
spellingShingle | Particle Physics - Experiment Duarte Ramos, Fernando Klempt, Wolfgang Nuiry, Francois-Xavier Experimental tests on the air cooling of the CLIC vertex detector |
title | Experimental tests on the air cooling of the CLIC vertex detector |
title_full | Experimental tests on the air cooling of the CLIC vertex detector |
title_fullStr | Experimental tests on the air cooling of the CLIC vertex detector |
title_full_unstemmed | Experimental tests on the air cooling of the CLIC vertex detector |
title_short | Experimental tests on the air cooling of the CLIC vertex detector |
title_sort | experimental tests on the air cooling of the clic vertex detector |
topic | Particle Physics - Experiment |
url | http://cds.cern.ch/record/2138963 |
work_keys_str_mv | AT duarteramosfernando experimentaltestsontheaircoolingoftheclicvertexdetector AT klemptwolfgang experimentaltestsontheaircoolingoftheclicvertexdetector AT nuiryfrancoisxavier experimentaltestsontheaircoolingoftheclicvertexdetector |