Cargando…

Experimental tests on the air cooling of the CLIC vertex detector

The strict requirements in terms of material budget for the inner region of the CLIC detector concept require the use of a dry gas for the cooling of the respective sensors. This, in conjunction with the compactness of the inner volumes, poses several challenges for the design of a cooling system th...

Descripción completa

Detalles Bibliográficos
Autores principales: Duarte Ramos, Fernando, Klempt, Wolfgang, Nuiry, Francois-Xavier
Lenguaje:eng
Publicado: 2016
Materias:
Acceso en línea:http://cds.cern.ch/record/2138963
_version_ 1780950065728192512
author Duarte Ramos, Fernando
Klempt, Wolfgang
Nuiry, Francois-Xavier
author_facet Duarte Ramos, Fernando
Klempt, Wolfgang
Nuiry, Francois-Xavier
author_sort Duarte Ramos, Fernando
collection CERN
description The strict requirements in terms of material budget for the inner region of the CLIC detector concept require the use of a dry gas for the cooling of the respective sensors. This, in conjunction with the compactness of the inner volumes, poses several challenges for the design of a cooling system that is able to fulfil the required detector specifications. This note summarizes the results obtained from experimental tests on the air cooling of the CLIC vertex detector as well as their comparison with the corresponding computational fluid dynamics simulations.
id cern-2138963
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling cern-21389632019-09-30T06:29:59Zhttp://cds.cern.ch/record/2138963engDuarte Ramos, FernandoKlempt, WolfgangNuiry, Francois-XavierExperimental tests on the air cooling of the CLIC vertex detectorParticle Physics - ExperimentThe strict requirements in terms of material budget for the inner region of the CLIC detector concept require the use of a dry gas for the cooling of the respective sensors. This, in conjunction with the compactness of the inner volumes, poses several challenges for the design of a cooling system that is able to fulfil the required detector specifications. This note summarizes the results obtained from experimental tests on the air cooling of the CLIC vertex detector as well as their comparison with the corresponding computational fluid dynamics simulations.CLICdp-Note-2016-002oai:cds.cern.ch:21389632016
spellingShingle Particle Physics - Experiment
Duarte Ramos, Fernando
Klempt, Wolfgang
Nuiry, Francois-Xavier
Experimental tests on the air cooling of the CLIC vertex detector
title Experimental tests on the air cooling of the CLIC vertex detector
title_full Experimental tests on the air cooling of the CLIC vertex detector
title_fullStr Experimental tests on the air cooling of the CLIC vertex detector
title_full_unstemmed Experimental tests on the air cooling of the CLIC vertex detector
title_short Experimental tests on the air cooling of the CLIC vertex detector
title_sort experimental tests on the air cooling of the clic vertex detector
topic Particle Physics - Experiment
url http://cds.cern.ch/record/2138963
work_keys_str_mv AT duarteramosfernando experimentaltestsontheaircoolingoftheclicvertexdetector
AT klemptwolfgang experimentaltestsontheaircoolingoftheclicvertexdetector
AT nuiryfrancoisxavier experimentaltestsontheaircoolingoftheclicvertexdetector