Cargando…
Simulations of a multi-layer extended gating grid
A novel idea to control ion back-flow in time projection chambers is to use a multi-layer extended gating grid to capture back-flowing ions at the expense of live time and electron transparency. In this initial study, I perform simulations of a four-layer grid for the ALICE and STAR time projection...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2016
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2140406 |
Sumario: | A novel idea to control ion back-flow in time projection chambers is to use a multi-layer extended gating grid to capture back-flowing ions at the expense of live time and electron transparency. In this initial study, I perform simulations of a four-layer grid for the ALICE and STAR time projection chambers, using $\text{Ne}-\text{CO}_{2}\;(90-10)$ and $\text{Ar}-\text{CH}_{4}\;(90-10)$ gas mixtures, respectively. I report the live time and electron transparency for both 90% and 99% ion back-flow suppression. Additionally, for the ALICE configuration I study several effects: using a mesh vs. wire-plane grid, including a magnetic field, and varying the over-voltage distribution in the gating region. For 90% ion back-flow suppression, I achieve 75% live time with 86% electron transparency for ALICE, and 95% live time with 83% electron transparency for STAR. |
---|