Cargando…

A new cryogenic test facility for large superconducting devices at CERN

To expand CERN testing capability to superconducting devices that cannot be installed in existing test facilities because of their size and/or mass, CERN is building a new cryogenic test facility for large and heavy devices. The first devices to be tested in the facility will be the S-FRS supercondu...

Descripción completa

Detalles Bibliográficos
Autores principales: Perin, A, Derking, J H, Serio, L, Stewart, L, Benda, V, Bremer, J, Pirotte, O
Lenguaje:eng
Publicado: 2015
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1757-899X/101/1/012185
http://cds.cern.ch/record/2145995
_version_ 1780950327327981568
author Perin, A
Derking, J H
Serio, L
Stewart, L
Benda, V
Bremer, J
Pirotte, O
author_facet Perin, A
Derking, J H
Serio, L
Stewart, L
Benda, V
Bremer, J
Pirotte, O
author_sort Perin, A
collection CERN
description To expand CERN testing capability to superconducting devices that cannot be installed in existing test facilities because of their size and/or mass, CERN is building a new cryogenic test facility for large and heavy devices. The first devices to be tested in the facility will be the S-FRS superconducting magnets for the FAIR project that is currently under construction at the GSI Research Center in Darmstadt, Germany. The facility will include a renovated cold box with 1.2 kW at 4.5 K equivalent power with its compression system, two independent 15 kW liquid nitrogen precooling and warm-up units, as well as a dedicated cryogenic distribution system providing cooling power to three independent test benches. The article presents the main input parameters and constraints used to define the cryogenic system and its infrastructure. The chosen layout and configuration of the facility is presented and the characteristics of the main components are described.
id cern-2145995
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2015
record_format invenio
spelling cern-21459952022-08-10T13:08:05Zdoi:10.1088/1757-899X/101/1/012185http://cds.cern.ch/record/2145995engPerin, ADerking, J HSerio, LStewart, LBenda, VBremer, JPirotte, OA new cryogenic test facility for large superconducting devices at CERNEngineeringTo expand CERN testing capability to superconducting devices that cannot be installed in existing test facilities because of their size and/or mass, CERN is building a new cryogenic test facility for large and heavy devices. The first devices to be tested in the facility will be the S-FRS superconducting magnets for the FAIR project that is currently under construction at the GSI Research Center in Darmstadt, Germany. The facility will include a renovated cold box with 1.2 kW at 4.5 K equivalent power with its compression system, two independent 15 kW liquid nitrogen precooling and warm-up units, as well as a dedicated cryogenic distribution system providing cooling power to three independent test benches. The article presents the main input parameters and constraints used to define the cryogenic system and its infrastructure. The chosen layout and configuration of the facility is presented and the characteristics of the main components are described.oai:cds.cern.ch:21459952015
spellingShingle Engineering
Perin, A
Derking, J H
Serio, L
Stewart, L
Benda, V
Bremer, J
Pirotte, O
A new cryogenic test facility for large superconducting devices at CERN
title A new cryogenic test facility for large superconducting devices at CERN
title_full A new cryogenic test facility for large superconducting devices at CERN
title_fullStr A new cryogenic test facility for large superconducting devices at CERN
title_full_unstemmed A new cryogenic test facility for large superconducting devices at CERN
title_short A new cryogenic test facility for large superconducting devices at CERN
title_sort new cryogenic test facility for large superconducting devices at cern
topic Engineering
url https://dx.doi.org/10.1088/1757-899X/101/1/012185
http://cds.cern.ch/record/2145995
work_keys_str_mv AT perina anewcryogenictestfacilityforlargesuperconductingdevicesatcern
AT derkingjh anewcryogenictestfacilityforlargesuperconductingdevicesatcern
AT seriol anewcryogenictestfacilityforlargesuperconductingdevicesatcern
AT stewartl anewcryogenictestfacilityforlargesuperconductingdevicesatcern
AT bendav anewcryogenictestfacilityforlargesuperconductingdevicesatcern
AT bremerj anewcryogenictestfacilityforlargesuperconductingdevicesatcern
AT pirotteo anewcryogenictestfacilityforlargesuperconductingdevicesatcern
AT perina newcryogenictestfacilityforlargesuperconductingdevicesatcern
AT derkingjh newcryogenictestfacilityforlargesuperconductingdevicesatcern
AT seriol newcryogenictestfacilityforlargesuperconductingdevicesatcern
AT stewartl newcryogenictestfacilityforlargesuperconductingdevicesatcern
AT bendav newcryogenictestfacilityforlargesuperconductingdevicesatcern
AT bremerj newcryogenictestfacilityforlargesuperconductingdevicesatcern
AT pirotteo newcryogenictestfacilityforlargesuperconductingdevicesatcern