Rotating-coil calibration in a reference quadrupole, considering roll-angle misalignment and higher-order harmonics
A method is proposed for calibrating the radius of a rotating coil sensor by relaxing the metrological constraints on alignment and field errors of the reference quadrupole. A coil radius calibration considering a roll-angle misalignment of the measurement bench, the magnet, and the motor-drive unit...
Autores principales: | , , , , |
---|---|
Formato: | info:eu-repo/semantics/article |
Lenguaje: | eng |
Publicado: |
Measurement
2016
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.measurement.2016.02.061 http://cds.cern.ch/record/2148402 |
_version_ | 1780950418071748608 |
---|---|
author | Arpaia, Pasquale Buzio, Marco Köster, Oliver Russenschuck, Stephan Severino, Giordana |
author_facet | Arpaia, Pasquale Buzio, Marco Köster, Oliver Russenschuck, Stephan Severino, Giordana |
author_sort | Arpaia, Pasquale |
collection | CERN |
description | A method is proposed for calibrating the radius of a rotating coil sensor by relaxing the metrological constraints on alignment and field errors of the reference quadrupole. A coil radius calibration considering a roll-angle misalignment of the measurement bench, the magnet, and the motor-drive unit is analyzed. Then, the error arising from higher-order harmonic field imperfections in the reference quadrupole is assessed. The method is validated by numerical field computation for both the higher-order harmonic errors and the roll-angle misalignment. Finally, an experimental proof-of-principle demonstration is car-ried out in a calibration magnet with sextupole harmonic. |
format | info:eu-repo/semantics/article |
id | cern-2148402 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2016 |
publisher | Measurement |
record_format | invenio |
spelling | cern-21484022019-09-30T06:29:59Z doi:10.1016/j.measurement.2016.02.061 http://cds.cern.ch/record/2148402 eng Arpaia, Pasquale Buzio, Marco Köster, Oliver Russenschuck, Stephan Severino, Giordana Rotating-coil calibration in a reference quadrupole, considering roll-angle misalignment and higher-order harmonics Accelerators and Storage Rings A method is proposed for calibrating the radius of a rotating coil sensor by relaxing the metrological constraints on alignment and field errors of the reference quadrupole. A coil radius calibration considering a roll-angle misalignment of the measurement bench, the magnet, and the motor-drive unit is analyzed. Then, the error arising from higher-order harmonic field imperfections in the reference quadrupole is assessed. The method is validated by numerical field computation for both the higher-order harmonic errors and the roll-angle misalignment. Finally, an experimental proof-of-principle demonstration is car-ried out in a calibration magnet with sextupole harmonic. info:eu-repo/grantAgreement/EC/FP7/606839 info:eu-repo/semantics/openAccess Education Level info:eu-repo/semantics/article http://cds.cern.ch/record/2148402 Measurement Measurement, (2016) pp. 74-82 2016 |
spellingShingle | Accelerators and Storage Rings Arpaia, Pasquale Buzio, Marco Köster, Oliver Russenschuck, Stephan Severino, Giordana Rotating-coil calibration in a reference quadrupole, considering roll-angle misalignment and higher-order harmonics |
title | Rotating-coil calibration in a reference quadrupole, considering roll-angle misalignment and higher-order harmonics |
title_full | Rotating-coil calibration in a reference quadrupole, considering roll-angle misalignment and higher-order harmonics |
title_fullStr | Rotating-coil calibration in a reference quadrupole, considering roll-angle misalignment and higher-order harmonics |
title_full_unstemmed | Rotating-coil calibration in a reference quadrupole, considering roll-angle misalignment and higher-order harmonics |
title_short | Rotating-coil calibration in a reference quadrupole, considering roll-angle misalignment and higher-order harmonics |
title_sort | rotating-coil calibration in a reference quadrupole, considering roll-angle misalignment and higher-order harmonics |
topic | Accelerators and Storage Rings |
url | https://dx.doi.org/10.1016/j.measurement.2016.02.061 http://cds.cern.ch/record/2148402 http://cds.cern.ch/record/2148402 |
work_keys_str_mv | AT arpaiapasquale rotatingcoilcalibrationinareferencequadrupoleconsideringrollanglemisalignmentandhigherorderharmonics AT buziomarco rotatingcoilcalibrationinareferencequadrupoleconsideringrollanglemisalignmentandhigherorderharmonics AT kosteroliver rotatingcoilcalibrationinareferencequadrupoleconsideringrollanglemisalignmentandhigherorderharmonics AT russenschuckstephan rotatingcoilcalibrationinareferencequadrupoleconsideringrollanglemisalignmentandhigherorderharmonics AT severinogiordana rotatingcoilcalibrationinareferencequadrupoleconsideringrollanglemisalignmentandhigherorderharmonics |