Performance Studies of Bulk Micromegas of Different Design Parameters

The present work involves the comparison of various bulk Micromegas detectors having different design parameters.Six detectors with amplification gaps of 64,128,192,220μm and mesh hole pitch of 63,78μm were tested at room temperature and normal gas pressure.Two setups were built to evaluate the effe...

Descripción completa

Detalles Bibliográficos
Autores principales: Bhattacharya, P., Bhattacharya, Sudeb, Majumdar, Nayana, Mukhopadhyay, Supratik, Sarkar, Sandip, Colas, Paul, Attie, David
Lenguaje:eng
Publicado: 2016
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1748-0221/9/04/C04037
http://cds.cern.ch/record/2152258
_version_ 1780950513777377280
author Bhattacharya, P.
Bhattacharya, Sudeb
Majumdar, Nayana
Mukhopadhyay, Supratik
Sarkar, Sandip
Colas, Paul
Attie, David
author_facet Bhattacharya, P.
Bhattacharya, Sudeb
Majumdar, Nayana
Mukhopadhyay, Supratik
Sarkar, Sandip
Colas, Paul
Attie, David
author_sort Bhattacharya, P.
collection CERN
description The present work involves the comparison of various bulk Micromegas detectors having different design parameters.Six detectors with amplification gaps of 64,128,192,220μm and mesh hole pitch of 63,78μm were tested at room temperature and normal gas pressure.Two setups were built to evaluate the effect of the variation of the amplification gap and mesh hole pitch on different detector characteristics.The gain, energy resolution and electron transmission of these Micromegas detectors were measured in Argon-Isobutane (90:10) gas mixture while the measurements of the ion backflow were carried out in P10 gas.These measured characteristics have been compared in detail to numerical simulations using the Garfield framework that combines packages such as neBEM, Magboltz and Heed.
id cern-2152258
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling cern-21522582023-03-14T19:35:48Zdoi:10.1088/1748-0221/9/04/C04037http://cds.cern.ch/record/2152258engBhattacharya, P.Bhattacharya, SudebMajumdar, NayanaMukhopadhyay, SupratikSarkar, SandipColas, PaulAttie, DavidPerformance Studies of Bulk Micromegas of Different Design Parametersphysics.ins-detDetectors and Experimental TechniquesThe present work involves the comparison of various bulk Micromegas detectors having different design parameters.Six detectors with amplification gaps of 64,128,192,220μm and mesh hole pitch of 63,78μm were tested at room temperature and normal gas pressure.Two setups were built to evaluate the effect of the variation of the amplification gap and mesh hole pitch on different detector characteristics.The gain, energy resolution and electron transmission of these Micromegas detectors were measured in Argon-Isobutane (90:10) gas mixture while the measurements of the ion backflow were carried out in P10 gas.These measured characteristics have been compared in detail to numerical simulations using the Garfield framework that combines packages such as neBEM, Magboltz and Heed.The present work involves the comparison of various bulk Micromegas detectors having different design parameters. Six detectors with amplification gaps of $64,~128,~192,~220 ~\mu\mathrm{m}$ and mesh hole pitch of $63,~78 ~\mu\mathrm{m}$ were tested at room temperature and normal gas pressure. Two setups were built to evaluate the effect of the variation of the amplification gap and mesh hole pitch on different detector characteristics. The gain, energy resolution and electron transmission of these Micromegas detectors were measured in Argon-Isobutane (90:10) gas mixture while the measurements of the ion backflow were carried out in P10 gas. These measured characteristics have been compared in detail to the numerical simulations using the Garfield framework that combines packages such as neBEM, Magboltz and Heed.arXiv:1605.02921oai:cds.cern.ch:21522582016-05-10
spellingShingle physics.ins-det
Detectors and Experimental Techniques
Bhattacharya, P.
Bhattacharya, Sudeb
Majumdar, Nayana
Mukhopadhyay, Supratik
Sarkar, Sandip
Colas, Paul
Attie, David
Performance Studies of Bulk Micromegas of Different Design Parameters
title Performance Studies of Bulk Micromegas of Different Design Parameters
title_full Performance Studies of Bulk Micromegas of Different Design Parameters
title_fullStr Performance Studies of Bulk Micromegas of Different Design Parameters
title_full_unstemmed Performance Studies of Bulk Micromegas of Different Design Parameters
title_short Performance Studies of Bulk Micromegas of Different Design Parameters
title_sort performance studies of bulk micromegas of different design parameters
topic physics.ins-det
Detectors and Experimental Techniques
url https://dx.doi.org/10.1088/1748-0221/9/04/C04037
http://cds.cern.ch/record/2152258
work_keys_str_mv AT bhattacharyap performancestudiesofbulkmicromegasofdifferentdesignparameters
AT bhattacharyasudeb performancestudiesofbulkmicromegasofdifferentdesignparameters
AT majumdarnayana performancestudiesofbulkmicromegasofdifferentdesignparameters
AT mukhopadhyaysupratik performancestudiesofbulkmicromegasofdifferentdesignparameters
AT sarkarsandip performancestudiesofbulkmicromegasofdifferentdesignparameters
AT colaspaul performancestudiesofbulkmicromegasofdifferentdesignparameters
AT attiedavid performancestudiesofbulkmicromegasofdifferentdesignparameters