Cargando…

Comparison of CMS Resistive Plate Chambers performance during LHC RUN-1 and RUN-2

The Resistive Plate Chambers detector system at the CMS experiment at the LHC provides robustness and redundancy to the muon trigger. A total of 1056 double-gap chambers cover the pseudo-rapidity region lt 1.6. The main detector parameters and environmental conditions are constantly and closely mo...

Descripción completa

Detalles Bibliográficos
Autor principal: Shah, Mehar Ali
Lenguaje:eng
Publicado: 2016
Materias:
Acceso en línea:http://cds.cern.ch/record/2155642
_version_ 1780950669261275136
author Shah, Mehar Ali
author_facet Shah, Mehar Ali
author_sort Shah, Mehar Ali
collection CERN
description The Resistive Plate Chambers detector system at the CMS experiment at the LHC provides robustness and redundancy to the muon trigger. A total of 1056 double-gap chambers cover the pseudo-rapidity region lt 1.6. The main detector parameters and environmental conditions are constantly and closely monitored to achieve operational stability and high quality data in the harsh conditions of the second run period of the LHC with center-of-mass energy of 13 TeV. First results of overall detector stability with 2015 data and comparisons with data from the LHC RUN-1 period at 8 TeV are presented.
id cern-2155642
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling cern-21556422019-09-30T06:29:59Zhttp://cds.cern.ch/record/2155642engShah, Mehar AliComparison of CMS Resistive Plate Chambers performance during LHC RUN-1 and RUN-2Detectors and Experimental TechniquesThe Resistive Plate Chambers detector system at the CMS experiment at the LHC provides robustness and redundancy to the muon trigger. A total of 1056 double-gap chambers cover the pseudo-rapidity region lt 1.6. The main detector parameters and environmental conditions are constantly and closely monitored to achieve operational stability and high quality data in the harsh conditions of the second run period of the LHC with center-of-mass energy of 13 TeV. First results of overall detector stability with 2015 data and comparisons with data from the LHC RUN-1 period at 8 TeV are presented.CMS-CR-2016-088oai:cds.cern.ch:21556422016-05-09
spellingShingle Detectors and Experimental Techniques
Shah, Mehar Ali
Comparison of CMS Resistive Plate Chambers performance during LHC RUN-1 and RUN-2
title Comparison of CMS Resistive Plate Chambers performance during LHC RUN-1 and RUN-2
title_full Comparison of CMS Resistive Plate Chambers performance during LHC RUN-1 and RUN-2
title_fullStr Comparison of CMS Resistive Plate Chambers performance during LHC RUN-1 and RUN-2
title_full_unstemmed Comparison of CMS Resistive Plate Chambers performance during LHC RUN-1 and RUN-2
title_short Comparison of CMS Resistive Plate Chambers performance during LHC RUN-1 and RUN-2
title_sort comparison of cms resistive plate chambers performance during lhc run-1 and run-2
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/2155642
work_keys_str_mv AT shahmeharali comparisonofcmsresistiveplatechambersperformanceduringlhcrun1andrun2