Cargando…

Medipix3RX: Characterizing the Medipix3 Redesign With Synchrotron Radiation

The Medipix3RX is the latest version of the Medipix3 photon counting ASICs, which implements two new operational modes, with respect to the Medipix2 ASIC, aimed at eliminating charge shared events (referred to as Charge Summing Mode (CSM)) and at providing spectroscopic information (referred to as C...

Descripción completa

Detalles Bibliográficos
Autores principales: Gimenez, Eva N, Ballabriga, Rafael, Blaj, Gabriel, Campbell, Michael, Dolbnya, Igor, Frodjh, Erik, Horswell, Ian, Llopart, Xavier, Marchal, Julien, McGrath, John, Omar, David, Plackett, Richard, Sawhney, Kawal, Tartoni, Nicola
Publicado: 2015
Materias:
XX
Acceso en línea:https://dx.doi.org/10.1109/TNS.2015.2425227
http://cds.cern.ch/record/2162874
_version_ 1780950985696346112
author Gimenez, Eva N
Ballabriga, Rafael
Blaj, Gabriel
Campbell, Michael
Dolbnya, Igor
Frodjh, Erik
Horswell, Ian
Llopart, Xavier
Marchal, Julien
McGrath, John
Omar, David
Plackett, Richard
Sawhney, Kawal
Tartoni, Nicola
author_facet Gimenez, Eva N
Ballabriga, Rafael
Blaj, Gabriel
Campbell, Michael
Dolbnya, Igor
Frodjh, Erik
Horswell, Ian
Llopart, Xavier
Marchal, Julien
McGrath, John
Omar, David
Plackett, Richard
Sawhney, Kawal
Tartoni, Nicola
author_sort Gimenez, Eva N
collection CERN
description The Medipix3RX is the latest version of the Medipix3 photon counting ASICs, which implements two new operational modes, with respect to the Medipix2 ASIC, aimed at eliminating charge shared events (referred to as Charge Summing Mode (CSM)) and at providing spectroscopic information (referred to as Colour Mode (CM)). The Medipix3RX is a redesign of the Medipix3v0 ASIC and corrects for the underperformance of CSM features observed in the previous version. This paper presents the results from synchrotron X-rays tests to evaluate the Medipix3RX ASIC performance. The newly implemented CSM algorithm eliminates the charge sharing effect at the same time as allocating the event to the readout pixel corresponding to the sensor pixel where the X-ray photon impinged. The new pixel trimming circuit led to a reduced dispersion between pixels. Further results of the linearity for all the gain modes, energy resolution and pixel uniformity are also presented.
id cern-2162874
institution Organización Europea para la Investigación Nuclear
publishDate 2015
record_format invenio
spelling cern-21628742019-09-30T06:29:59Zdoi:10.1109/TNS.2015.2425227http://cds.cern.ch/record/2162874Gimenez, Eva NBallabriga, RafaelBlaj, GabrielCampbell, MichaelDolbnya, IgorFrodjh, ErikHorswell, IanLlopart, XavierMarchal, JulienMcGrath, JohnOmar, DavidPlackett, RichardSawhney, KawalTartoni, NicolaMedipix3RX: Characterizing the Medipix3 Redesign With Synchrotron RadiationXXThe Medipix3RX is the latest version of the Medipix3 photon counting ASICs, which implements two new operational modes, with respect to the Medipix2 ASIC, aimed at eliminating charge shared events (referred to as Charge Summing Mode (CSM)) and at providing spectroscopic information (referred to as Colour Mode (CM)). The Medipix3RX is a redesign of the Medipix3v0 ASIC and corrects for the underperformance of CSM features observed in the previous version. This paper presents the results from synchrotron X-rays tests to evaluate the Medipix3RX ASIC performance. The newly implemented CSM algorithm eliminates the charge sharing effect at the same time as allocating the event to the readout pixel corresponding to the sensor pixel where the X-ray photon impinged. The new pixel trimming circuit led to a reduced dispersion between pixels. Further results of the linearity for all the gain modes, energy resolution and pixel uniformity are also presented.oai:cds.cern.ch:21628742015
spellingShingle XX
Gimenez, Eva N
Ballabriga, Rafael
Blaj, Gabriel
Campbell, Michael
Dolbnya, Igor
Frodjh, Erik
Horswell, Ian
Llopart, Xavier
Marchal, Julien
McGrath, John
Omar, David
Plackett, Richard
Sawhney, Kawal
Tartoni, Nicola
Medipix3RX: Characterizing the Medipix3 Redesign With Synchrotron Radiation
title Medipix3RX: Characterizing the Medipix3 Redesign With Synchrotron Radiation
title_full Medipix3RX: Characterizing the Medipix3 Redesign With Synchrotron Radiation
title_fullStr Medipix3RX: Characterizing the Medipix3 Redesign With Synchrotron Radiation
title_full_unstemmed Medipix3RX: Characterizing the Medipix3 Redesign With Synchrotron Radiation
title_short Medipix3RX: Characterizing the Medipix3 Redesign With Synchrotron Radiation
title_sort medipix3rx: characterizing the medipix3 redesign with synchrotron radiation
topic XX
url https://dx.doi.org/10.1109/TNS.2015.2425227
http://cds.cern.ch/record/2162874
work_keys_str_mv AT gimenezevan medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation
AT ballabrigarafael medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation
AT blajgabriel medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation
AT campbellmichael medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation
AT dolbnyaigor medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation
AT frodjherik medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation
AT horswellian medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation
AT llopartxavier medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation
AT marchaljulien medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation
AT mcgrathjohn medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation
AT omardavid medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation
AT plackettrichard medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation
AT sawhneykawal medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation
AT tartoninicola medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation