Cargando…
Medipix3RX: Characterizing the Medipix3 Redesign With Synchrotron Radiation
The Medipix3RX is the latest version of the Medipix3 photon counting ASICs, which implements two new operational modes, with respect to the Medipix2 ASIC, aimed at eliminating charge shared events (referred to as Charge Summing Mode (CSM)) and at providing spectroscopic information (referred to as C...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Publicado: |
2015
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/TNS.2015.2425227 http://cds.cern.ch/record/2162874 |
_version_ | 1780950985696346112 |
---|---|
author | Gimenez, Eva N Ballabriga, Rafael Blaj, Gabriel Campbell, Michael Dolbnya, Igor Frodjh, Erik Horswell, Ian Llopart, Xavier Marchal, Julien McGrath, John Omar, David Plackett, Richard Sawhney, Kawal Tartoni, Nicola |
author_facet | Gimenez, Eva N Ballabriga, Rafael Blaj, Gabriel Campbell, Michael Dolbnya, Igor Frodjh, Erik Horswell, Ian Llopart, Xavier Marchal, Julien McGrath, John Omar, David Plackett, Richard Sawhney, Kawal Tartoni, Nicola |
author_sort | Gimenez, Eva N |
collection | CERN |
description | The Medipix3RX is the latest version of the Medipix3 photon counting ASICs, which implements two new operational modes, with respect to the Medipix2 ASIC, aimed at eliminating charge shared events (referred to as Charge Summing Mode (CSM)) and at providing spectroscopic information (referred to as Colour Mode (CM)). The Medipix3RX is a redesign of the Medipix3v0 ASIC and corrects for the underperformance of CSM features observed in the previous version. This paper presents the results from synchrotron X-rays tests to evaluate the Medipix3RX ASIC performance. The newly implemented CSM algorithm eliminates the charge sharing effect at the same time as allocating the event to the readout pixel corresponding to the sensor pixel where the X-ray photon impinged. The new pixel trimming circuit led to a reduced dispersion between pixels. Further results of the linearity for all the gain modes, energy resolution and pixel uniformity are also presented. |
id | cern-2162874 |
institution | Organización Europea para la Investigación Nuclear |
publishDate | 2015 |
record_format | invenio |
spelling | cern-21628742019-09-30T06:29:59Zdoi:10.1109/TNS.2015.2425227http://cds.cern.ch/record/2162874Gimenez, Eva NBallabriga, RafaelBlaj, GabrielCampbell, MichaelDolbnya, IgorFrodjh, ErikHorswell, IanLlopart, XavierMarchal, JulienMcGrath, JohnOmar, DavidPlackett, RichardSawhney, KawalTartoni, NicolaMedipix3RX: Characterizing the Medipix3 Redesign With Synchrotron RadiationXXThe Medipix3RX is the latest version of the Medipix3 photon counting ASICs, which implements two new operational modes, with respect to the Medipix2 ASIC, aimed at eliminating charge shared events (referred to as Charge Summing Mode (CSM)) and at providing spectroscopic information (referred to as Colour Mode (CM)). The Medipix3RX is a redesign of the Medipix3v0 ASIC and corrects for the underperformance of CSM features observed in the previous version. This paper presents the results from synchrotron X-rays tests to evaluate the Medipix3RX ASIC performance. The newly implemented CSM algorithm eliminates the charge sharing effect at the same time as allocating the event to the readout pixel corresponding to the sensor pixel where the X-ray photon impinged. The new pixel trimming circuit led to a reduced dispersion between pixels. Further results of the linearity for all the gain modes, energy resolution and pixel uniformity are also presented.oai:cds.cern.ch:21628742015 |
spellingShingle | XX Gimenez, Eva N Ballabriga, Rafael Blaj, Gabriel Campbell, Michael Dolbnya, Igor Frodjh, Erik Horswell, Ian Llopart, Xavier Marchal, Julien McGrath, John Omar, David Plackett, Richard Sawhney, Kawal Tartoni, Nicola Medipix3RX: Characterizing the Medipix3 Redesign With Synchrotron Radiation |
title | Medipix3RX: Characterizing the Medipix3 Redesign With Synchrotron Radiation |
title_full | Medipix3RX: Characterizing the Medipix3 Redesign With Synchrotron Radiation |
title_fullStr | Medipix3RX: Characterizing the Medipix3 Redesign With Synchrotron Radiation |
title_full_unstemmed | Medipix3RX: Characterizing the Medipix3 Redesign With Synchrotron Radiation |
title_short | Medipix3RX: Characterizing the Medipix3 Redesign With Synchrotron Radiation |
title_sort | medipix3rx: characterizing the medipix3 redesign with synchrotron radiation |
topic | XX |
url | https://dx.doi.org/10.1109/TNS.2015.2425227 http://cds.cern.ch/record/2162874 |
work_keys_str_mv | AT gimenezevan medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation AT ballabrigarafael medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation AT blajgabriel medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation AT campbellmichael medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation AT dolbnyaigor medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation AT frodjherik medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation AT horswellian medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation AT llopartxavier medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation AT marchaljulien medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation AT mcgrathjohn medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation AT omardavid medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation AT plackettrichard medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation AT sawhneykawal medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation AT tartoninicola medipix3rxcharacterizingthemedipix3redesignwithsynchrotronradiation |