Cargando…
Phase1 upgrade of the CMS-HF Calorimeter
In this presentation, results of the Phase I upgrade of the CMS Hadron Forward Calorimeter (HF) are discussed. The CMS-HF Calorimeter was using regular PMTs. Cherenkov light produced in the quartz fibers embedded in the iron absorber was read out with the PMTs. However, occasionally, stray muons hit...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2016
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.22323/1.276.0194 http://cds.cern.ch/record/2197525 |
_version_ | 1780951175031422976 |
---|---|
author | Gulmez, Erhan |
author_facet | Gulmez, Erhan |
author_sort | Gulmez, Erhan |
collection | CERN |
description | In this presentation, results of the Phase I upgrade of the CMS Hadron Forward Calorimeter (HF) are discussed. The CMS-HF Calorimeter was using regular PMTs. Cherenkov light produced in the quartz fibers embedded in the iron absorber was read out with the PMTs. However, occasionally, stray muons hitting the PMT windows cause Cherenkov radiation in the PMT itself and produce large signals. These large signals mimic a very high-energy particle and are tagged as important by the trigger. To reduce this problem, PMTs had to be replaced. The four-anode PMTs that were chosen have thinner windows; thereby reducing the Cherenkov radiation in the PMT window. As part of the upgrade, the read-out electronics is to be replaced so that the PMTs are read out in two channels by connecting each pair of anodes to a single channel. Information provided by these two channels will help us reject the false signals due to the stray muons since the Cherenkov radiation in the PMT window is more likely to produce a signal only in one anode as opposed to a real signal whose light illuminates all four anodes. |
id | cern-2197525 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2016 |
record_format | invenio |
spelling | cern-21975252019-09-30T06:29:59Zdoi:10.22323/1.276.0194http://cds.cern.ch/record/2197525engGulmez, ErhanPhase1 upgrade of the CMS-HF CalorimeterDetectors and Experimental TechniquesIn this presentation, results of the Phase I upgrade of the CMS Hadron Forward Calorimeter (HF) are discussed. The CMS-HF Calorimeter was using regular PMTs. Cherenkov light produced in the quartz fibers embedded in the iron absorber was read out with the PMTs. However, occasionally, stray muons hitting the PMT windows cause Cherenkov radiation in the PMT itself and produce large signals. These large signals mimic a very high-energy particle and are tagged as important by the trigger. To reduce this problem, PMTs had to be replaced. The four-anode PMTs that were chosen have thinner windows; thereby reducing the Cherenkov radiation in the PMT window. As part of the upgrade, the read-out electronics is to be replaced so that the PMTs are read out in two channels by connecting each pair of anodes to a single channel. Information provided by these two channels will help us reject the false signals due to the stray muons since the Cherenkov radiation in the PMT window is more likely to produce a signal only in one anode as opposed to a real signal whose light illuminates all four anodes.CMS-CR-2016-145oai:cds.cern.ch:21975252016-06-28 |
spellingShingle | Detectors and Experimental Techniques Gulmez, Erhan Phase1 upgrade of the CMS-HF Calorimeter |
title | Phase1 upgrade of the CMS-HF Calorimeter |
title_full | Phase1 upgrade of the CMS-HF Calorimeter |
title_fullStr | Phase1 upgrade of the CMS-HF Calorimeter |
title_full_unstemmed | Phase1 upgrade of the CMS-HF Calorimeter |
title_short | Phase1 upgrade of the CMS-HF Calorimeter |
title_sort | phase1 upgrade of the cms-hf calorimeter |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.22323/1.276.0194 http://cds.cern.ch/record/2197525 |
work_keys_str_mv | AT gulmezerhan phase1upgradeofthecmshfcalorimeter |