Cargando…
Dose rate effects in radiation damage to the Hadron Endcap scintillators
We present measurements of the reduction of light output by plastic scintillators irradiated in the CMS detector during the 8 TeV run of the Large Hadron Collider and show that they indicate a strong dose rate effect. The damage for a given dose is larger for lower dose rate exposures. The results a...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2016
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2202965 |
_version_ | 1780951339114692608 |
---|---|
author | CMS Collaboration |
author_facet | CMS Collaboration |
author_sort | CMS Collaboration |
collection | CERN |
description | We present measurements of the reduction of light output by plastic scintillators irradiated
in the CMS detector during the 8 TeV run of the Large Hadron Collider and
show that they indicate a strong dose rate effect. The damage for a given dose is larger
for lower dose rate exposures. The results agree with previous measurements of dose
rate effects, but are stronger due to the very low dose rates probed. We show that the
scaling with dose rate is consistent with that expected from diffusion effects. |
id | cern-2202965 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2016 |
record_format | invenio |
spelling | cern-22029652019-09-30T06:29:59Zhttp://cds.cern.ch/record/2202965engCMS CollaborationDose rate effects in radiation damage to the Hadron Endcap scintillatorsDetectors and Experimental TechniquesWe present measurements of the reduction of light output by plastic scintillators irradiated in the CMS detector during the 8 TeV run of the Large Hadron Collider and show that they indicate a strong dose rate effect. The damage for a given dose is larger for lower dose rate exposures. The results agree with previous measurements of dose rate effects, but are stronger due to the very low dose rates probed. We show that the scaling with dose rate is consistent with that expected from diffusion effects.CMS-DP-2016-045CERN-CMS-DP-2016-045oai:cds.cern.ch:22029652016-07-25 |
spellingShingle | Detectors and Experimental Techniques CMS Collaboration Dose rate effects in radiation damage to the Hadron Endcap scintillators |
title | Dose rate effects in radiation damage to the Hadron Endcap scintillators |
title_full | Dose rate effects in radiation damage to the Hadron Endcap scintillators |
title_fullStr | Dose rate effects in radiation damage to the Hadron Endcap scintillators |
title_full_unstemmed | Dose rate effects in radiation damage to the Hadron Endcap scintillators |
title_short | Dose rate effects in radiation damage to the Hadron Endcap scintillators |
title_sort | dose rate effects in radiation damage to the hadron endcap scintillators |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/2202965 |
work_keys_str_mv | AT cmscollaboration doserateeffectsinradiationdamagetothehadronendcapscintillators |