Cargando…
Long-term stability test of a triple GEM detector
The main aim of the study is to perform the long-term stability test of gain of the single mask triple GEM detector. A simple method is used for this long-term stability test using a radioactive X-ray source with high activity. The test is continued till accumulation of charge per unit area > 12....
Autores principales: | , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2016
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/1748-0221/11/10/T10001 http://cds.cern.ch/record/2203725 |
_version_ | 1780951367077068800 |
---|---|
author | Adak, R.P. Biswas, S. Das, S. Ghosal, D. Ghosh, S.K. Mondal, A. Nag, D. Nayak, T.K. Patra, R.N. Prasad, S. K Raha, S. Sahu, P.K. Sahu, S. Swain, S. |
author_facet | Adak, R.P. Biswas, S. Das, S. Ghosal, D. Ghosh, S.K. Mondal, A. Nag, D. Nayak, T.K. Patra, R.N. Prasad, S. K Raha, S. Sahu, P.K. Sahu, S. Swain, S. |
author_sort | Adak, R.P. |
collection | CERN |
description | The main aim of the study is to perform the long-term stability test of gain of the single mask triple GEM detector. A simple method is used for this long-term stability test using a radioactive X-ray source with high activity. The test is continued till accumulation of charge per unit area > 12.0 mC/mm(2). The details of the chamber fabrication, the test set-up, the method of measurement and the test results are presented in this paper. |
id | cern-2203725 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2016 |
record_format | invenio |
spelling | cern-22037252023-03-14T19:35:43Zdoi:10.1088/1748-0221/11/10/T10001http://cds.cern.ch/record/2203725engAdak, R.P.Biswas, S.Das, S.Ghosal, D.Ghosh, S.K.Mondal, A.Nag, D.Nayak, T.K.Patra, R.N.Prasad, S. KRaha, S.Sahu, P.K.Sahu, S.Swain, S.Long-term stability test of a triple GEM detectorhep-exParticle Physics - Experimentphysics.ins-detDetectors and Experimental TechniquesThe main aim of the study is to perform the long-term stability test of gain of the single mask triple GEM detector. A simple method is used for this long-term stability test using a radioactive X-ray source with high activity. The test is continued till accumulation of charge per unit area > 12.0 mC/mm(2). The details of the chamber fabrication, the test set-up, the method of measurement and the test results are presented in this paper.The main aim of the study is to perform the long-term stability test of gain of the single mask triple GEM detector. A simple method is used for this long- term stability test using a radioactive X-ray source with high activity. The test is continued till accumulation of charge per unit area > 12.0 mC/mm2. The details of the chamber fabrication, the test set-up, the method of measurement and the test results are presented in this paper.arXiv:1608.00562oai:cds.cern.ch:22037252016-07-30 |
spellingShingle | hep-ex Particle Physics - Experiment physics.ins-det Detectors and Experimental Techniques Adak, R.P. Biswas, S. Das, S. Ghosal, D. Ghosh, S.K. Mondal, A. Nag, D. Nayak, T.K. Patra, R.N. Prasad, S. K Raha, S. Sahu, P.K. Sahu, S. Swain, S. Long-term stability test of a triple GEM detector |
title | Long-term stability test of a triple GEM detector |
title_full | Long-term stability test of a triple GEM detector |
title_fullStr | Long-term stability test of a triple GEM detector |
title_full_unstemmed | Long-term stability test of a triple GEM detector |
title_short | Long-term stability test of a triple GEM detector |
title_sort | long-term stability test of a triple gem detector |
topic | hep-ex Particle Physics - Experiment physics.ins-det Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1088/1748-0221/11/10/T10001 http://cds.cern.ch/record/2203725 |
work_keys_str_mv | AT adakrp longtermstabilitytestofatriplegemdetector AT biswass longtermstabilitytestofatriplegemdetector AT dass longtermstabilitytestofatriplegemdetector AT ghosald longtermstabilitytestofatriplegemdetector AT ghoshsk longtermstabilitytestofatriplegemdetector AT mondala longtermstabilitytestofatriplegemdetector AT nagd longtermstabilitytestofatriplegemdetector AT nayaktk longtermstabilitytestofatriplegemdetector AT patrarn longtermstabilitytestofatriplegemdetector AT prasadsk longtermstabilitytestofatriplegemdetector AT rahas longtermstabilitytestofatriplegemdetector AT sahupk longtermstabilitytestofatriplegemdetector AT sahus longtermstabilitytestofatriplegemdetector AT swains longtermstabilitytestofatriplegemdetector |