Cargando…

Double Chooz Improved Multi-Detector Measurements

<!--HTML--><p>The Double Chooz experiment (DC) is a reactor neutrino oscillation experiment running at Chooz nuclear power plant (2 reactors) in France. In 2011, DC first reported indication of non-zero &theta;<sub>13</sub> with the far detector (FD) located at the maximu...

Descripción completa

Detalles Bibliográficos
Autor principal: Cabrera Serra, Anatael
Lenguaje:eng
Publicado: 2016
Materias:
Acceso en línea:http://cds.cern.ch/record/2217579
_version_ 1780952098768158720
author Cabrera Serra, Anatael
author_facet Cabrera Serra, Anatael
author_sort Cabrera Serra, Anatael
collection CERN
description <!--HTML--><p>The Double Chooz experiment (DC) is a reactor neutrino oscillation experiment running at Chooz nuclear power plant (2 reactors) in France. In 2011, DC first reported indication of non-zero &theta;<sub>13</sub> with the far detector (FD) located at the maximum of oscillation effects (i.e. disappearance), thus challenging the CHOOZ non-observation limit. A robust observation of &theta;<sub>13</sub> followed in 2012 by the Daya Bay experiments with multiple detector configurations. Since 2015 DC runs in a multi-detector configuration making thus the impact of several otherwise dominating systematics reduce strongly. DC&rsquo;s unique almost &quot;iso-flux&quot; site, allows the near detector (ND) to become a direct accurate non-oscillation reference to the FD. Our first multi-detector results at MORIOND-2016 showed an intriguing deviation of &theta;<sub>13</sub> with respect to the world average. We will address this issue in this seminar. The combined &quot;reactor-&theta;<sub>13</sub>&quot; measurement is expected to remain as the world reference for decades. Since this measurement relies on systematics uncertainties in the unprecedented per mille level in neutrino physics, the redundancy of multiple experiments (Daya Bay, DC, RENO) is considered most critical to ensure the robustness of both the accuracy and the precision. This combined measurement is today a critical reference throughout the field, having leading impact to possible indirect manifestations of neutrino CP-violation and atmospheric mass ordering when combined with the world measurements &mdash; one of the key highlights of the NEUTRINO-2016 conference.</p> <p>In this seminar, DC will release &mdash; for the first time &mdash; the results of a novel analysis method aimed to maximise the accuracy; i.e. the goodness of the central value of &theta;<sub>13</sub>. Despite a major increase of statistical power, a conservative approach on systematics has been adopted for now. Beyond oscillation physics, DC will release &mdash; also for the first time &mdash; our most precise single-detector results allowing high precision reactor spectrum characterisation, including both shape and normalisation. This is a particularly hot topic since DC provided the first evidence of a sizeable spectral distorsions in May 2014 &mdash; confirmed later on by RENO (June) and Daya Bay (July) &mdash; questioning the accuracy and precision of today&#39;s reactor neutrino predictions technology.</p>
id cern-2217579
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling cern-22175792022-11-02T22:31:28Zhttp://cds.cern.ch/record/2217579engCabrera Serra, AnataelDouble Chooz Improved Multi-Detector MeasurementsDouble Chooz Improved Multi-Detector MeasurementsEP Seminar<!--HTML--><p>The Double Chooz experiment (DC) is a reactor neutrino oscillation experiment running at Chooz nuclear power plant (2 reactors) in France. In 2011, DC first reported indication of non-zero &theta;<sub>13</sub> with the far detector (FD) located at the maximum of oscillation effects (i.e. disappearance), thus challenging the CHOOZ non-observation limit. A robust observation of &theta;<sub>13</sub> followed in 2012 by the Daya Bay experiments with multiple detector configurations. Since 2015 DC runs in a multi-detector configuration making thus the impact of several otherwise dominating systematics reduce strongly. DC&rsquo;s unique almost &quot;iso-flux&quot; site, allows the near detector (ND) to become a direct accurate non-oscillation reference to the FD. Our first multi-detector results at MORIOND-2016 showed an intriguing deviation of &theta;<sub>13</sub> with respect to the world average. We will address this issue in this seminar. The combined &quot;reactor-&theta;<sub>13</sub>&quot; measurement is expected to remain as the world reference for decades. Since this measurement relies on systematics uncertainties in the unprecedented per mille level in neutrino physics, the redundancy of multiple experiments (Daya Bay, DC, RENO) is considered most critical to ensure the robustness of both the accuracy and the precision. This combined measurement is today a critical reference throughout the field, having leading impact to possible indirect manifestations of neutrino CP-violation and atmospheric mass ordering when combined with the world measurements &mdash; one of the key highlights of the NEUTRINO-2016 conference.</p> <p>In this seminar, DC will release &mdash; for the first time &mdash; the results of a novel analysis method aimed to maximise the accuracy; i.e. the goodness of the central value of &theta;<sub>13</sub>. Despite a major increase of statistical power, a conservative approach on systematics has been adopted for now. Beyond oscillation physics, DC will release &mdash; also for the first time &mdash; our most precise single-detector results allowing high precision reactor spectrum characterisation, including both shape and normalisation. This is a particularly hot topic since DC provided the first evidence of a sizeable spectral distorsions in May 2014 &mdash; confirmed later on by RENO (June) and Daya Bay (July) &mdash; questioning the accuracy and precision of today&#39;s reactor neutrino predictions technology.</p>oai:cds.cern.ch:22175792016
spellingShingle EP Seminar
Cabrera Serra, Anatael
Double Chooz Improved Multi-Detector Measurements
title Double Chooz Improved Multi-Detector Measurements
title_full Double Chooz Improved Multi-Detector Measurements
title_fullStr Double Chooz Improved Multi-Detector Measurements
title_full_unstemmed Double Chooz Improved Multi-Detector Measurements
title_short Double Chooz Improved Multi-Detector Measurements
title_sort double chooz improved multi-detector measurements
topic EP Seminar
url http://cds.cern.ch/record/2217579
work_keys_str_mv AT cabreraserraanatael doublechoozimprovedmultidetectormeasurements