Numerical study of saturation steam/water mixture flow and flashing initial sub-cooled water flow inside throttling devices

<!--HTML-->Saturation of steam/water mixture flow and flashing initial sub-cooled flow inside throttling devices (i.e., safety and control valves) is investigated here. Due to thermal non-equilibrium and mechanical non-equilibrium effects, this phenomenon is of actual interest in the research...

Descripción completa

Detalles Bibliográficos
Autor principal: Dang Le, QUANG
Lenguaje:eng
Publicado: 2016
Materias:
Acceso en línea:http://cds.cern.ch/record/2220113
_version_ 1780952179010437120
author Dang Le, QUANG
author_facet Dang Le, QUANG
author_sort Dang Le, QUANG
collection CERN
description <!--HTML-->Saturation of steam/water mixture flow and flashing initial sub-cooled flow inside throttling devices (i.e., safety and control valves) is investigated here. Due to thermal non-equilibrium and mechanical non-equilibrium effects, this phenomenon is of actual interest in the research community. Thermal non-equilibrium effect is accounted for boiling delay before vaporization when flow experiences sudden depressurization and reaches the saturation state. Mechanical non-equilibrium effect is encountered with slip between vapor and liquid. In this work, a Computational Fluid-Dynamics (CFD) approach to model this phenomenon inside throttling devices is proposed. To validate CFD results, different nozzle geometries are analyzed, comparing numerical results with experimental data. Two cases are studied: Case 1: saturation steam/water mixture flow inside 2D convergent-divergent nozzle (inlet, outlet and throat diameter of nozzle are 0.1213m, 0.0452m and 0.0191m respectively). In this benchmark, a range of total inlet pressure (134 – 189kPa) and inlet liquid mass fraction (0 - 0.36) is investigated. Results show an agreement with experimental data in term of mass flow rate. • Case 2: initial sub-cooled water flow inside 2D-axisymmetric and 3D convergent-divergent nozzle (both of inlet, outlet diameter are 0.051m and nozzle throat diameter is 0.025m). Validation of CFD model is performed with total inlet pressure, inlet temperature and outlet pressure equal to 555.9kPa, 422.25K and 402.5kPa, respectively. An agreement between CFD results and experiment data in both mass flow rate and local values of vapor fraction is also observed. This simulation is the first part of a project aimed to generate more data for establishing a new formula of sizing valves in case of two-phase flow with phase change.
id cern-2220113
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling cern-22201132022-11-02T22:12:32Zhttp://cds.cern.ch/record/2220113engDang Le, QUANGNumerical study of saturation steam/water mixture flow and flashing initial sub-cooled water flow inside throttling devicesCryogenic Safety - HSE seminarHSE Seminar<!--HTML-->Saturation of steam/water mixture flow and flashing initial sub-cooled flow inside throttling devices (i.e., safety and control valves) is investigated here. Due to thermal non-equilibrium and mechanical non-equilibrium effects, this phenomenon is of actual interest in the research community. Thermal non-equilibrium effect is accounted for boiling delay before vaporization when flow experiences sudden depressurization and reaches the saturation state. Mechanical non-equilibrium effect is encountered with slip between vapor and liquid. In this work, a Computational Fluid-Dynamics (CFD) approach to model this phenomenon inside throttling devices is proposed. To validate CFD results, different nozzle geometries are analyzed, comparing numerical results with experimental data. Two cases are studied: Case 1: saturation steam/water mixture flow inside 2D convergent-divergent nozzle (inlet, outlet and throat diameter of nozzle are 0.1213m, 0.0452m and 0.0191m respectively). In this benchmark, a range of total inlet pressure (134 – 189kPa) and inlet liquid mass fraction (0 - 0.36) is investigated. Results show an agreement with experimental data in term of mass flow rate. • Case 2: initial sub-cooled water flow inside 2D-axisymmetric and 3D convergent-divergent nozzle (both of inlet, outlet diameter are 0.051m and nozzle throat diameter is 0.025m). Validation of CFD model is performed with total inlet pressure, inlet temperature and outlet pressure equal to 555.9kPa, 422.25K and 402.5kPa, respectively. An agreement between CFD results and experiment data in both mass flow rate and local values of vapor fraction is also observed. This simulation is the first part of a project aimed to generate more data for establishing a new formula of sizing valves in case of two-phase flow with phase change.oai:cds.cern.ch:22201132016
spellingShingle HSE Seminar
Dang Le, QUANG
Numerical study of saturation steam/water mixture flow and flashing initial sub-cooled water flow inside throttling devices
title Numerical study of saturation steam/water mixture flow and flashing initial sub-cooled water flow inside throttling devices
title_full Numerical study of saturation steam/water mixture flow and flashing initial sub-cooled water flow inside throttling devices
title_fullStr Numerical study of saturation steam/water mixture flow and flashing initial sub-cooled water flow inside throttling devices
title_full_unstemmed Numerical study of saturation steam/water mixture flow and flashing initial sub-cooled water flow inside throttling devices
title_short Numerical study of saturation steam/water mixture flow and flashing initial sub-cooled water flow inside throttling devices
title_sort numerical study of saturation steam/water mixture flow and flashing initial sub-cooled water flow inside throttling devices
topic HSE Seminar
url http://cds.cern.ch/record/2220113
work_keys_str_mv AT danglequang numericalstudyofsaturationsteamwatermixtureflowandflashinginitialsubcooledwaterflowinsidethrottlingdevices
AT danglequang cryogenicsafetyhseseminar