Cargando…

Determination of the efficiency of the hodoscopes during the Drell-Yan run

The COMPASS trigger system is mainly composed of fast plastic scintillators working as hodoscopes. For the selection of events of physical interest during the COMPASS Drell-Yan run in 2015 it was configured to trigger single- and dimuon-events. Unbiased trigger decisions can be used to determine the...

Descripción completa

Detalles Bibliográficos
Autor principal: Lobert, Lukas
Lenguaje:eng
Publicado: 2016
Materias:
Acceso en línea:http://cds.cern.ch/record/2220919
_version_ 1780952213240152064
author Lobert, Lukas
author_facet Lobert, Lukas
author_sort Lobert, Lukas
collection CERN
description The COMPASS trigger system is mainly composed of fast plastic scintillators working as hodoscopes. For the selection of events of physical interest during the COMPASS Drell-Yan run in 2015 it was configured to trigger single- and dimuon-events. Unbiased trigger decisions can be used to determine the efficiency of the six symmetrically oriented hodoscopes used in 2015. The unbiasedness of the trigger is based on the usage of the hadron calorimeter trigger (CT) which was used on two dates during the run: The first time in the beginning and the second one in the middle respectively. Due to different beam conditions between the two dates a direct comparison between the results is unfortunately difficult. Especially in the beginning of the run, most of the strips of different hodoscopes show between 90% and often even 100%-efficiency. Compared to the results from the middle of the run, the efficiency of several strips seemed to get much worse during this time. Furthermore it can be seen that the method of determining the efficiency for each hodoscope strip separately works only for those hodoscopes where the track resolution is several times smaller than the strip width. Unfortunately a confirmation of this trend for dates earlier and later cannot be created by using the same methods since no further data sets with CT trigger exist.
id cern-2220919
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling cern-22209192019-09-30T06:29:59Zhttp://cds.cern.ch/record/2220919engLobert, LukasDetermination of the efficiency of the hodoscopes during the Drell-Yan runPhysics in GeneralThe COMPASS trigger system is mainly composed of fast plastic scintillators working as hodoscopes. For the selection of events of physical interest during the COMPASS Drell-Yan run in 2015 it was configured to trigger single- and dimuon-events. Unbiased trigger decisions can be used to determine the efficiency of the six symmetrically oriented hodoscopes used in 2015. The unbiasedness of the trigger is based on the usage of the hadron calorimeter trigger (CT) which was used on two dates during the run: The first time in the beginning and the second one in the middle respectively. Due to different beam conditions between the two dates a direct comparison between the results is unfortunately difficult. Especially in the beginning of the run, most of the strips of different hodoscopes show between 90% and often even 100%-efficiency. Compared to the results from the middle of the run, the efficiency of several strips seemed to get much worse during this time. Furthermore it can be seen that the method of determining the efficiency for each hodoscope strip separately works only for those hodoscopes where the track resolution is several times smaller than the strip width. Unfortunately a confirmation of this trend for dates earlier and later cannot be created by using the same methods since no further data sets with CT trigger exist.CERN-STUDENTS-Note-2016-253oai:cds.cern.ch:22209192016-10-03
spellingShingle Physics in General
Lobert, Lukas
Determination of the efficiency of the hodoscopes during the Drell-Yan run
title Determination of the efficiency of the hodoscopes during the Drell-Yan run
title_full Determination of the efficiency of the hodoscopes during the Drell-Yan run
title_fullStr Determination of the efficiency of the hodoscopes during the Drell-Yan run
title_full_unstemmed Determination of the efficiency of the hodoscopes during the Drell-Yan run
title_short Determination of the efficiency of the hodoscopes during the Drell-Yan run
title_sort determination of the efficiency of the hodoscopes during the drell-yan run
topic Physics in General
url http://cds.cern.ch/record/2220919
work_keys_str_mv AT lobertlukas determinationoftheefficiencyofthehodoscopesduringthedrellyanrun