Block 4 and Cluster D - Safety
<!--HTML-->After transfer of Bloc4 test facility to SM18 its safety system was upgraded in 2014/2015 for its 3 existing test cryostats. In 2016 a new test facility HFM (High Field Magnet) was integrated in the Bloc4. A new test facility Cluster D which is similar to HFM is in a process of inst...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2016
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2224465 |
Sumario: | <!--HTML-->After transfer of Bloc4 test facility to SM18 its safety system was upgraded in 2014/2015 for its 3 existing test cryostats. In 2016 a new test facility HFM (High Field Magnet) was integrated in the Bloc4. A new test facility Cluster D which is similar to HFM is in a process of installation in SM18. The Presentation is dedicated to safety strategy of Bloc4 and Cluster D and focused on an analysis of risk conditions and on the real behaviour of safety valves in case of discharge. Protection of sub-atmospheric circuits is also discussed. |
---|