Cargando…

Ανάπτυξη Ηλεκτρονικών Συστημάτων Λήψης Δεδομένων και Ελέγχου για ένα Πείραμα Συγκρουόμενων Δεσμών pp σε Ενέργεια Κέντρου Μάζας 14TeV (Πείραμα CMS στον Επιταχυντή LHC).

The architecture of a data acquisition (DAQ) and slow control system for the electromagnetic calorimeter preshower detector of the CMS (Compact Muon Solenoid) experiment - one of the LHC (Large Hadron Collider) experiments of CERN - has been studied. The system consists of the detector Front End ele...

Descripción completa

Detalles Bibliográficos
Autor principal: Kloukinas, Constantine
Lenguaje:gre
Publicado: Ioannina U. 1997
Materias:
Acceso en línea:http://cds.cern.ch/record/2226011
_version_ 1780952410645069824
author Kloukinas, Constantine
author_facet Kloukinas, Constantine
author_sort Kloukinas, Constantine
collection CERN
description The architecture of a data acquisition (DAQ) and slow control system for the electromagnetic calorimeter preshower detector of the CMS (Compact Muon Solenoid) experiment - one of the LHC (Large Hadron Collider) experiments of CERN - has been studied. The system consists of the detector Front End electronics and of a data transmission system delivering the preshower information to the central DAQ system of the CMS experiment. The functionality of the Front End electronics is presented. The operation of the data transmission system, based on a ring topology, is described and the system design parameters are estimated. The system design criteria are the increased reliability, the use of radiation hard optoelectronic components, the low power consumption and the minimization of the number of Application Specific Integrated Circuits (ASICs) needed for building the system. The use of commercially available VLSI technologies for fabricating the ASICs of the proposed system capable to withstand the radiation levels in the preshower region has been investigated. The radiation hardness of a commercially available BiCMOS 0.8μ VLSI technology has been studied. The results show a threshold voltage shift of -130mV for the NMOS transistors and -190mV for the PMOS transistors, after an irradiation dose of 1.3MRad. The transconductance drops about 8% for the NMOS and 7% for the PMOS at the same irradiation level. A sudden increase of leakage current was observed after an irradiation dose of 14KRad. The study located the leakage currents originating from the turn on of parasitic FOXFET (Field Oxide FET) devices.
id cern-2226011
institution Organización Europea para la Investigación Nuclear
language gre
publishDate 1997
publisher Ioannina U.
record_format invenio
spelling cern-22260112019-09-30T06:29:59Zhttp://cds.cern.ch/record/2226011greKloukinas, ConstantineΑνάπτυξη Ηλεκτρονικών Συστημάτων Λήψης Δεδομένων και Ελέγχου για ένα Πείραμα Συγκρουόμενων Δεσμών pp σε Ενέργεια Κέντρου Μάζας 14TeV (Πείραμα CMS στον Επιταχυντή LHC).EngineeringThe architecture of a data acquisition (DAQ) and slow control system for the electromagnetic calorimeter preshower detector of the CMS (Compact Muon Solenoid) experiment - one of the LHC (Large Hadron Collider) experiments of CERN - has been studied. The system consists of the detector Front End electronics and of a data transmission system delivering the preshower information to the central DAQ system of the CMS experiment. The functionality of the Front End electronics is presented. The operation of the data transmission system, based on a ring topology, is described and the system design parameters are estimated. The system design criteria are the increased reliability, the use of radiation hard optoelectronic components, the low power consumption and the minimization of the number of Application Specific Integrated Circuits (ASICs) needed for building the system. The use of commercially available VLSI technologies for fabricating the ASICs of the proposed system capable to withstand the radiation levels in the preshower region has been investigated. The radiation hardness of a commercially available BiCMOS 0.8μ VLSI technology has been studied. The results show a threshold voltage shift of -130mV for the NMOS transistors and -190mV for the PMOS transistors, after an irradiation dose of 1.3MRad. The transconductance drops about 8% for the NMOS and 7% for the PMOS at the same irradiation level. A sudden increase of leakage current was observed after an irradiation dose of 14KRad. The study located the leakage currents originating from the turn on of parasitic FOXFET (Field Oxide FET) devices.Ioannina U.CERN-THESIS-97-016oai:cds.cern.ch:22260111997
spellingShingle Engineering
Kloukinas, Constantine
Ανάπτυξη Ηλεκτρονικών Συστημάτων Λήψης Δεδομένων και Ελέγχου για ένα Πείραμα Συγκρουόμενων Δεσμών pp σε Ενέργεια Κέντρου Μάζας 14TeV (Πείραμα CMS στον Επιταχυντή LHC).
title Ανάπτυξη Ηλεκτρονικών Συστημάτων Λήψης Δεδομένων και Ελέγχου για ένα Πείραμα Συγκρουόμενων Δεσμών pp σε Ενέργεια Κέντρου Μάζας 14TeV (Πείραμα CMS στον Επιταχυντή LHC).
title_full Ανάπτυξη Ηλεκτρονικών Συστημάτων Λήψης Δεδομένων και Ελέγχου για ένα Πείραμα Συγκρουόμενων Δεσμών pp σε Ενέργεια Κέντρου Μάζας 14TeV (Πείραμα CMS στον Επιταχυντή LHC).
title_fullStr Ανάπτυξη Ηλεκτρονικών Συστημάτων Λήψης Δεδομένων και Ελέγχου για ένα Πείραμα Συγκρουόμενων Δεσμών pp σε Ενέργεια Κέντρου Μάζας 14TeV (Πείραμα CMS στον Επιταχυντή LHC).
title_full_unstemmed Ανάπτυξη Ηλεκτρονικών Συστημάτων Λήψης Δεδομένων και Ελέγχου για ένα Πείραμα Συγκρουόμενων Δεσμών pp σε Ενέργεια Κέντρου Μάζας 14TeV (Πείραμα CMS στον Επιταχυντή LHC).
title_short Ανάπτυξη Ηλεκτρονικών Συστημάτων Λήψης Δεδομένων και Ελέγχου για ένα Πείραμα Συγκρουόμενων Δεσμών pp σε Ενέργεια Κέντρου Μάζας 14TeV (Πείραμα CMS στον Επιταχυντή LHC).
title_sort ανάπτυξη ηλεκτρονικών συστημάτων λήψης δεδομένων και ελέγχου για ένα πείραμα συγκρουόμενων δεσμών pp σε ενέργεια κέντρου μάζας 14tev (πείραμα cms στον επιταχυντή lhc).
topic Engineering
url http://cds.cern.ch/record/2226011
work_keys_str_mv AT kloukinasconstantine anaptyxēēlektronikōnsystēmatōnlēpsēsdedomenōnkaielenchougiaenapeiramasynkrouomenōndesmōnppseenergeiakentroumazas14tevpeiramacmsstonepitachyntēlhc