Cargando…
Beam test results for the upgraded LHCb RICH optoelectronic readout system
Starting from 2018, the LHCb detector will be upgraded to operate at higher luminosity and extend its potential for new discoveries. The Ring Imaging Cherenkov (RICH) detectors are one of the key components for particle identification of the LHCb detector and the upgraded specifications will require...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2016
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2017.02.038 http://cds.cern.ch/record/2228915 |
_version_ | 1780952477232791552 |
---|---|
author | Carniti, P. |
author_facet | Carniti, P. |
author_sort | Carniti, P. |
collection | CERN |
description | Starting from 2018, the LHCb detector will be upgraded to operate at higher luminosity and extend its potential for new discoveries. The Ring Imaging Cherenkov (RICH) detectors are one of the key components for particle identification of the LHCb detector and the upgraded specifications will require a redesign of the optoelectronic readout chain. In the present work, we describe the experimental setup and the results of the tests carried out with a particle beam to assess and validate the performance of the optoelectronic readout system. |
id | cern-2228915 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2016 |
record_format | invenio |
spelling | cern-22289152023-03-14T19:33:37Zdoi:10.1016/j.nima.2017.02.038http://cds.cern.ch/record/2228915engCarniti, P.Beam test results for the upgraded LHCb RICH optoelectronic readout systemphysics.ins-detDetectors and Experimental TechniquesStarting from 2018, the LHCb detector will be upgraded to operate at higher luminosity and extend its potential for new discoveries. The Ring Imaging Cherenkov (RICH) detectors are one of the key components for particle identification of the LHCb detector and the upgraded specifications will require a redesign of the optoelectronic readout chain. In the present work, we describe the experimental setup and the results of the tests carried out with a particle beam to assess and validate the performance of the optoelectronic readout system.arXiv:1610.10006oai:cds.cern.ch:22289152016-10-31 |
spellingShingle | physics.ins-det Detectors and Experimental Techniques Carniti, P. Beam test results for the upgraded LHCb RICH optoelectronic readout system |
title | Beam test results for the upgraded LHCb RICH optoelectronic readout system |
title_full | Beam test results for the upgraded LHCb RICH optoelectronic readout system |
title_fullStr | Beam test results for the upgraded LHCb RICH optoelectronic readout system |
title_full_unstemmed | Beam test results for the upgraded LHCb RICH optoelectronic readout system |
title_short | Beam test results for the upgraded LHCb RICH optoelectronic readout system |
title_sort | beam test results for the upgraded lhcb rich optoelectronic readout system |
topic | physics.ins-det Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/j.nima.2017.02.038 http://cds.cern.ch/record/2228915 |
work_keys_str_mv | AT carnitip beamtestresultsfortheupgradedlhcbrichoptoelectronicreadoutsystem |