Real-time calibration and alignment of the LHCb RICH detectors

In 2015, the LHCb experiment established a new and unique software trigger strategy with the purpose of increasing the purity of the signal events by applying the same algorithms online and offline. To achieve this, real-time calibration and alignment of all LHCb sub-systems is needed to provide ver...

Descripción completa

Detalles Bibliográficos
Autor principal: He, Jibo
Lenguaje:eng
Publicado: 2016
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2016.12.041
http://cds.cern.ch/record/2229385
_version_ 1780952484466917376
author He, Jibo
author_facet He, Jibo
author_sort He, Jibo
collection CERN
description In 2015, the LHCb experiment established a new and unique software trigger strategy with the purpose of increasing the purity of the signal events by applying the same algorithms online and offline. To achieve this, real-time calibration and alignment of all LHCb sub-systems is needed to provide vertexing, tracking, and particle identification of the best possible quality. The calibration of the refractive index of the RICH radiators, the calibration of the Hybrid Photon Detector image, and the alignment of the RICH mirror system, are reported in this contribution. The stability of the RICH performance and the particle identification performance are also discussed.
id cern-2229385
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling cern-22293852023-06-29T04:02:30Zdoi:10.1016/j.nima.2016.12.041http://cds.cern.ch/record/2229385engHe, JiboReal-time calibration and alignment of the LHCb RICH detectorshep-exParticle Physics - Experimentphysics.ins-detDetectors and Experimental TechniquesIn 2015, the LHCb experiment established a new and unique software trigger strategy with the purpose of increasing the purity of the signal events by applying the same algorithms online and offline. To achieve this, real-time calibration and alignment of all LHCb sub-systems is needed to provide vertexing, tracking, and particle identification of the best possible quality. The calibration of the refractive index of the RICH radiators, the calibration of the Hybrid Photon Detector image, and the alignment of the RICH mirror system, are reported in this contribution. The stability of the RICH performance and the particle identification performance are also discussed.arXiv:1611.00296oai:cds.cern.ch:22293852016-11-01
spellingShingle hep-ex
Particle Physics - Experiment
physics.ins-det
Detectors and Experimental Techniques
He, Jibo
Real-time calibration and alignment of the LHCb RICH detectors
title Real-time calibration and alignment of the LHCb RICH detectors
title_full Real-time calibration and alignment of the LHCb RICH detectors
title_fullStr Real-time calibration and alignment of the LHCb RICH detectors
title_full_unstemmed Real-time calibration and alignment of the LHCb RICH detectors
title_short Real-time calibration and alignment of the LHCb RICH detectors
title_sort real-time calibration and alignment of the lhcb rich detectors
topic hep-ex
Particle Physics - Experiment
physics.ins-det
Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nima.2016.12.041
http://cds.cern.ch/record/2229385
work_keys_str_mv AT hejibo realtimecalibrationandalignmentofthelhcbrichdetectors