Post-Mortem Analysis after High-Power Operation of the TD24_R05 Tested in Xbox_1

The CLIC prototype structure TD24_R05 has been high power tested in Xbox_1 in 2013. This report summarizes all examinations conducted after the high power test including bead-pull measurements, structure cutting, metrology and SEM observations. A synthesis of the various results is then made. The st...

Descripción completa

Detalles Bibliográficos
Autores principales: Degiovanni, Alberto, Wegner, Rolf, Mouriz Irazabal, Nerea, Aicheler, Markus
Lenguaje:eng
Publicado: 2016
Materias:
Acceso en línea:http://cds.cern.ch/record/2238910
_version_ 1780952945244766208
author Degiovanni, Alberto
Wegner, Rolf
Mouriz Irazabal, Nerea
Aicheler, Markus
author_facet Degiovanni, Alberto
Wegner, Rolf
Mouriz Irazabal, Nerea
Aicheler, Markus
author_sort Degiovanni, Alberto
collection CERN
description The CLIC prototype structure TD24_R05 has been high power tested in Xbox_1 in 2013. This report summarizes all examinations conducted after the high power test including bead-pull measurements, structure cutting, metrology and SEM observations. A synthesis of the various results is then made. The structure developed a hot cell progressively during operation and detuning was observed after the test was complete. The post mortem examination clearly showed a developed standing wave pattern which was explained by the physical deformation of one of the coupler iris. An elevated breakdown count through SEM imaging in the suspected hot cell however could not be confirmed. Neither any particular feature offering an explanation for the observed longitudinal breakdown distribution could be detected.
id cern-2238910
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling cern-22389102023-07-20T15:02:27Zhttp://cds.cern.ch/record/2238910engDegiovanni, AlbertoWegner, RolfMouriz Irazabal, NereaAicheler, MarkusPost-Mortem Analysis after High-Power Operation of the TD24_R05 Tested in Xbox_1Accelerators and Storage RingsThe CLIC prototype structure TD24_R05 has been high power tested in Xbox_1 in 2013. This report summarizes all examinations conducted after the high power test including bead-pull measurements, structure cutting, metrology and SEM observations. A synthesis of the various results is then made. The structure developed a hot cell progressively during operation and detuning was observed after the test was complete. The post mortem examination clearly showed a developed standing wave pattern which was explained by the physical deformation of one of the coupler iris. An elevated breakdown count through SEM imaging in the suspected hot cell however could not be confirmed. Neither any particular feature offering an explanation for the observed longitudinal breakdown distribution could be detected.CERN-ACC-2016-0337CLIC-Note-1070oai:cds.cern.ch:22389102016-08-01
spellingShingle Accelerators and Storage Rings
Degiovanni, Alberto
Wegner, Rolf
Mouriz Irazabal, Nerea
Aicheler, Markus
Post-Mortem Analysis after High-Power Operation of the TD24_R05 Tested in Xbox_1
title Post-Mortem Analysis after High-Power Operation of the TD24_R05 Tested in Xbox_1
title_full Post-Mortem Analysis after High-Power Operation of the TD24_R05 Tested in Xbox_1
title_fullStr Post-Mortem Analysis after High-Power Operation of the TD24_R05 Tested in Xbox_1
title_full_unstemmed Post-Mortem Analysis after High-Power Operation of the TD24_R05 Tested in Xbox_1
title_short Post-Mortem Analysis after High-Power Operation of the TD24_R05 Tested in Xbox_1
title_sort post-mortem analysis after high-power operation of the td24_r05 tested in xbox_1
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/2238910
work_keys_str_mv AT degiovannialberto postmortemanalysisafterhighpoweroperationofthetd24r05testedinxbox1
AT wegnerrolf postmortemanalysisafterhighpoweroperationofthetd24r05testedinxbox1
AT mourizirazabalnerea postmortemanalysisafterhighpoweroperationofthetd24r05testedinxbox1
AT aichelermarkus postmortemanalysisafterhighpoweroperationofthetd24r05testedinxbox1