Cargando…
Continuous and fast calibration of the CMS experiment: design of the automated workflows and operational experience
The exploitation of the full physics potential of the LHC experiments requires fast and efficient processing of the largest possible dataset with the most refined understanding of the detector conditions. To face this challenge, the CMS collaboration has setup an infrastructure for the continuous un...
Autores principales: | , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2017
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/1742-6596/898/3/032041 http://cds.cern.ch/record/2253526 |
_version_ | 1780953561296797696 |
---|---|
author | Oramus, Piotr Karol Cerminara, Gianluca Pfeiffer, Andreas Franzoni, Giovanni Govi, Giacomo Maria Musich, Marco Di Guida, Salvatore |
author_facet | Oramus, Piotr Karol Cerminara, Gianluca Pfeiffer, Andreas Franzoni, Giovanni Govi, Giacomo Maria Musich, Marco Di Guida, Salvatore |
author_sort | Oramus, Piotr Karol |
collection | CERN |
description | The exploitation of the full physics potential of the LHC experiments requires fast and efficient processing of the largest possible dataset with the most refined understanding of the detector conditions. To face this challenge, the CMS collaboration has setup an infrastructure for the continuous unattended computation of the alignment and calibration constants, allowing for a refined knowledge of the most time-critical parameters already a few hours after the data have been saved to disk. This is the prompt calibration framework which, since the beginning of the LHC Run-I, enables the analysis and the High Level Trigger of the experiment to consume the most up-to-date conditions optimizing the performance of the physics objects. In the Run-II this setup has been further expanded to include even more complex calibration algorithms requiring higher statistics to reach the needed precision. This imposed the introduction of a new paradigm in the creation of the calibration datasets for unattended workflows and opened the door to a further step in performance. The paper reviews the design of these automated calibration workflows, the operational experience in the Run-II and the monitoring infrastructure developed to ensure the reliability of the service. |
id | cern-2253526 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2017 |
record_format | invenio |
spelling | cern-22535262019-10-15T15:17:35Zdoi:10.1088/1742-6596/898/3/032041http://cds.cern.ch/record/2253526engOramus, Piotr KarolCerminara, GianlucaPfeiffer, AndreasFranzoni, GiovanniGovi, Giacomo MariaMusich, MarcoDi Guida, SalvatoreContinuous and fast calibration of the CMS experiment: design of the automated workflows and operational experienceDetectors and Experimental TechniquesThe exploitation of the full physics potential of the LHC experiments requires fast and efficient processing of the largest possible dataset with the most refined understanding of the detector conditions. To face this challenge, the CMS collaboration has setup an infrastructure for the continuous unattended computation of the alignment and calibration constants, allowing for a refined knowledge of the most time-critical parameters already a few hours after the data have been saved to disk. This is the prompt calibration framework which, since the beginning of the LHC Run-I, enables the analysis and the High Level Trigger of the experiment to consume the most up-to-date conditions optimizing the performance of the physics objects. In the Run-II this setup has been further expanded to include even more complex calibration algorithms requiring higher statistics to reach the needed precision. This imposed the introduction of a new paradigm in the creation of the calibration datasets for unattended workflows and opened the door to a further step in performance. The paper reviews the design of these automated calibration workflows, the operational experience in the Run-II and the monitoring infrastructure developed to ensure the reliability of the service.CMS-CR-2017-058oai:cds.cern.ch:22535262017-02-20 |
spellingShingle | Detectors and Experimental Techniques Oramus, Piotr Karol Cerminara, Gianluca Pfeiffer, Andreas Franzoni, Giovanni Govi, Giacomo Maria Musich, Marco Di Guida, Salvatore Continuous and fast calibration of the CMS experiment: design of the automated workflows and operational experience |
title | Continuous and fast calibration of the CMS experiment: design of the automated workflows and operational experience |
title_full | Continuous and fast calibration of the CMS experiment: design of the automated workflows and operational experience |
title_fullStr | Continuous and fast calibration of the CMS experiment: design of the automated workflows and operational experience |
title_full_unstemmed | Continuous and fast calibration of the CMS experiment: design of the automated workflows and operational experience |
title_short | Continuous and fast calibration of the CMS experiment: design of the automated workflows and operational experience |
title_sort | continuous and fast calibration of the cms experiment: design of the automated workflows and operational experience |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1088/1742-6596/898/3/032041 http://cds.cern.ch/record/2253526 |
work_keys_str_mv | AT oramuspiotrkarol continuousandfastcalibrationofthecmsexperimentdesignoftheautomatedworkflowsandoperationalexperience AT cerminaragianluca continuousandfastcalibrationofthecmsexperimentdesignoftheautomatedworkflowsandoperationalexperience AT pfeifferandreas continuousandfastcalibrationofthecmsexperimentdesignoftheautomatedworkflowsandoperationalexperience AT franzonigiovanni continuousandfastcalibrationofthecmsexperimentdesignoftheautomatedworkflowsandoperationalexperience AT govigiacomomaria continuousandfastcalibrationofthecmsexperimentdesignoftheautomatedworkflowsandoperationalexperience AT musichmarco continuousandfastcalibrationofthecmsexperimentdesignoftheautomatedworkflowsandoperationalexperience AT diguidasalvatore continuousandfastcalibrationofthecmsexperimentdesignoftheautomatedworkflowsandoperationalexperience |