Cargando…

Performance study of Philips digital silicon photomultiplier coupled to scintillating crystals

Silicon photomultipliers (SiPMs) and scintillators are often arranged in the shape of arrays in Positron Emission Tomography (PET) systems. Digital SiPMs provide signal readout in single photon avalanche diode (SPAD) level. From the photon count rate measurement of each SPAD cell of digital SiPM, we...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Z., Pizzichemi, M., Auffray, E., Lecoq, P., Paganoni, M.
Lenguaje:eng
Publicado: 2016
Materias:
XX
Acceso en línea:https://dx.doi.org/10.1088/1748-0221/11/01/P01017
http://cds.cern.ch/record/2255746
_version_ 1780953709724827648
author Liu, Z.
Pizzichemi, M.
Auffray, E.
Lecoq, P.
Paganoni, M.
author_facet Liu, Z.
Pizzichemi, M.
Auffray, E.
Lecoq, P.
Paganoni, M.
author_sort Liu, Z.
collection CERN
description Silicon photomultipliers (SiPMs) and scintillators are often arranged in the shape of arrays in Positron Emission Tomography (PET) systems. Digital SiPMs provide signal readout in single photon avalanche diode (SPAD) level. From the photon count rate measurement of each SPAD cell of digital SiPM, we found that the output scintillating photons distribute in an area larger than the scintillator physical coupling area. Taking advantage of the possibility to enable/disable individual cells of the digital SiPM, a group of Lutetium-yttrium oxyorthosilicate (LYSO) crystals with different dimensions coupled to a digital SiPM was used to study the influence of using different SiPM active area on the number of photons detected, energy resolution and coincidence time resolution (CTR). For the same crystal coupled to the digital SiPM, the larger the active area of digital SiPM, the higher the number of photons detected. The larger active area of the digital SiPM also results in a better energy resolution after saturation correction. The best energy resolution full width half maximum (FWHM) obtained for the 2 × 2 × 5 mm3, 2 × 2 × 10 mm3, 2 × 2 × 15 mm3, 2 × 2 × 20 mm3 LYSO crystals was 10.7%, 11.6%, 12.1%, 12.5%, respectively. For crystals with different cross sections coupled to the digital SiPM, we found that the larger the cross section of coupling area, the more photons were detected and thus a better energy resolution was obtained. The CTR of crystals fully wrapped with Teflon or without wrapping was measured by positioning two identical crystals facing each other. A larger area of digital SiPM improves the CTR and the CTR reaches the plateau when the active area is larger than 2.2 × 2.2 mm2 with both two configurations of wrapping. The best CTR value for the 2 × 2 × 5 mm3, 2 × 2 × 10 mm3, 2 × 2 × 15 mm3, 2 × 2 × 20 mm3 LYSO crystals was 128.9 ps, 148.4 ps, 171.6 ps, 177.9 ps, respectively. The measurements performed lead us to conclude that optimising the coupling between crystal and SiPM to extract more scintillating photons can improve the energy resolution and CTR.
id cern-2255746
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling cern-22557462022-08-10T12:45:10Zdoi:10.1088/1748-0221/11/01/P01017http://cds.cern.ch/record/2255746engLiu, Z.Pizzichemi, M.Auffray, E.Lecoq, P.Paganoni, M.Performance study of Philips digital silicon photomultiplier coupled to scintillating crystalsXXSilicon photomultipliers (SiPMs) and scintillators are often arranged in the shape of arrays in Positron Emission Tomography (PET) systems. Digital SiPMs provide signal readout in single photon avalanche diode (SPAD) level. From the photon count rate measurement of each SPAD cell of digital SiPM, we found that the output scintillating photons distribute in an area larger than the scintillator physical coupling area. Taking advantage of the possibility to enable/disable individual cells of the digital SiPM, a group of Lutetium-yttrium oxyorthosilicate (LYSO) crystals with different dimensions coupled to a digital SiPM was used to study the influence of using different SiPM active area on the number of photons detected, energy resolution and coincidence time resolution (CTR). For the same crystal coupled to the digital SiPM, the larger the active area of digital SiPM, the higher the number of photons detected. The larger active area of the digital SiPM also results in a better energy resolution after saturation correction. The best energy resolution full width half maximum (FWHM) obtained for the 2 × 2 × 5 mm3, 2 × 2 × 10 mm3, 2 × 2 × 15 mm3, 2 × 2 × 20 mm3 LYSO crystals was 10.7%, 11.6%, 12.1%, 12.5%, respectively. For crystals with different cross sections coupled to the digital SiPM, we found that the larger the cross section of coupling area, the more photons were detected and thus a better energy resolution was obtained. The CTR of crystals fully wrapped with Teflon or without wrapping was measured by positioning two identical crystals facing each other. A larger area of digital SiPM improves the CTR and the CTR reaches the plateau when the active area is larger than 2.2 × 2.2 mm2 with both two configurations of wrapping. The best CTR value for the 2 × 2 × 5 mm3, 2 × 2 × 10 mm3, 2 × 2 × 15 mm3, 2 × 2 × 20 mm3 LYSO crystals was 128.9 ps, 148.4 ps, 171.6 ps, 177.9 ps, respectively. The measurements performed lead us to conclude that optimising the coupling between crystal and SiPM to extract more scintillating photons can improve the energy resolution and CTR.oai:cds.cern.ch:22557462016
spellingShingle XX
Liu, Z.
Pizzichemi, M.
Auffray, E.
Lecoq, P.
Paganoni, M.
Performance study of Philips digital silicon photomultiplier coupled to scintillating crystals
title Performance study of Philips digital silicon photomultiplier coupled to scintillating crystals
title_full Performance study of Philips digital silicon photomultiplier coupled to scintillating crystals
title_fullStr Performance study of Philips digital silicon photomultiplier coupled to scintillating crystals
title_full_unstemmed Performance study of Philips digital silicon photomultiplier coupled to scintillating crystals
title_short Performance study of Philips digital silicon photomultiplier coupled to scintillating crystals
title_sort performance study of philips digital silicon photomultiplier coupled to scintillating crystals
topic XX
url https://dx.doi.org/10.1088/1748-0221/11/01/P01017
http://cds.cern.ch/record/2255746
work_keys_str_mv AT liuz performancestudyofphilipsdigitalsiliconphotomultipliercoupledtoscintillatingcrystals
AT pizzichemim performancestudyofphilipsdigitalsiliconphotomultipliercoupledtoscintillatingcrystals
AT auffraye performancestudyofphilipsdigitalsiliconphotomultipliercoupledtoscintillatingcrystals
AT lecoqp performancestudyofphilipsdigitalsiliconphotomultipliercoupledtoscintillatingcrystals
AT paganonim performancestudyofphilipsdigitalsiliconphotomultipliercoupledtoscintillatingcrystals