Cargando…

Experimental Ion Mobility measurements in Ne-CO$_2$ and CO$_2$-N$_2$ mixtures

In this paper we present the experimental results for the mobility, K0, of ions in neon-carbon dioxide (Ne-CO2) and carbon dioxide-nitrogen (CO2-N2) gaseous mixtures for total pressures ranging from 8–12 Torr, reduced electric fields in the 10–25 Td range, at room temperature. Regarding the Ne-CO2 m...

Descripción completa

Detalles Bibliográficos
Autores principales: Encarnação, P.M.C.C., Cortez, A.F.V., Veenhof, R., Neves, P.N.B., Santos, F.P., Trindade, A.M.F., Borges, F.I.G.M., Conde, C.A.N.
Lenguaje:eng
Publicado: 2016
Materias:
XX
Acceso en línea:https://dx.doi.org/10.1088/1748-0221/11/05/P05005
http://cds.cern.ch/record/2255747
_version_ 1780953709946077184
author Encarnação, P.M.C.C.
Cortez, A.F.V.
Veenhof, R.
Neves, P.N.B.
Santos, F.P.
Trindade, A.M.F.
Borges, F.I.G.M.
Conde, C.A.N.
author_facet Encarnação, P.M.C.C.
Cortez, A.F.V.
Veenhof, R.
Neves, P.N.B.
Santos, F.P.
Trindade, A.M.F.
Borges, F.I.G.M.
Conde, C.A.N.
author_sort Encarnação, P.M.C.C.
collection CERN
description In this paper we present the experimental results for the mobility, K0, of ions in neon-carbon dioxide (Ne-CO2) and carbon dioxide-nitrogen (CO2-N2) gaseous mixtures for total pressures ranging from 8–12 Torr, reduced electric fields in the 10–25 Td range, at room temperature. Regarding the Ne-CO2 mixture only one peak was observed for CO2 concentrations above 25%, which has been identified as an ion originated in CO2, while below 25% of CO2 a second-small peak appears at the left side of the main peak, which has been attributed to impurities. The mobility values for the main peak range between 3.51 ± 0.05 and 1.07 ± 0.01 cm2V−1s−1 in the 10%-99% interval of CO2, and from 4.61 ± 0.19 to 3.00 ± 0.09 cm2V−1s−1 for the second peak observed (10%–25% of CO2). For the CO2-N2, the time-of-arrival spectra displayed only one peak for CO2 concentrations above 10%, which was attributed to ions originated in CO2, namely CO2+(CO2), with a second peak appearing for CO2 concentrations below 10%. This second peak, with higher mobility, was attributed to CO2+ ions. The mobility values of the main peak range between 2.11 ± 0.04 and 1.10 ± 0.03 cm2V−1s−1 in the 1%–99% interval of CO2, while the second peak's from 2.26 ± 0.02 and 1.95 ± 0.04 cm2V−1s−1 (1%–10% of CO2). The inverse of the mobility displays an aproximately linear dependence on the CO2 concentration in the mixture.
id cern-2255747
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling cern-22557472022-08-10T12:45:11Zdoi:10.1088/1748-0221/11/05/P05005http://cds.cern.ch/record/2255747engEncarnação, P.M.C.C.Cortez, A.F.V.Veenhof, R.Neves, P.N.B.Santos, F.P.Trindade, A.M.F.Borges, F.I.G.M.Conde, C.A.N.Experimental Ion Mobility measurements in Ne-CO$_2$ and CO$_2$-N$_2$ mixturesXXIn this paper we present the experimental results for the mobility, K0, of ions in neon-carbon dioxide (Ne-CO2) and carbon dioxide-nitrogen (CO2-N2) gaseous mixtures for total pressures ranging from 8–12 Torr, reduced electric fields in the 10–25 Td range, at room temperature. Regarding the Ne-CO2 mixture only one peak was observed for CO2 concentrations above 25%, which has been identified as an ion originated in CO2, while below 25% of CO2 a second-small peak appears at the left side of the main peak, which has been attributed to impurities. The mobility values for the main peak range between 3.51 ± 0.05 and 1.07 ± 0.01 cm2V−1s−1 in the 10%-99% interval of CO2, and from 4.61 ± 0.19 to 3.00 ± 0.09 cm2V−1s−1 for the second peak observed (10%–25% of CO2). For the CO2-N2, the time-of-arrival spectra displayed only one peak for CO2 concentrations above 10%, which was attributed to ions originated in CO2, namely CO2+(CO2), with a second peak appearing for CO2 concentrations below 10%. This second peak, with higher mobility, was attributed to CO2+ ions. The mobility values of the main peak range between 2.11 ± 0.04 and 1.10 ± 0.03 cm2V−1s−1 in the 1%–99% interval of CO2, while the second peak's from 2.26 ± 0.02 and 1.95 ± 0.04 cm2V−1s−1 (1%–10% of CO2). The inverse of the mobility displays an aproximately linear dependence on the CO2 concentration in the mixture.oai:cds.cern.ch:22557472016
spellingShingle XX
Encarnação, P.M.C.C.
Cortez, A.F.V.
Veenhof, R.
Neves, P.N.B.
Santos, F.P.
Trindade, A.M.F.
Borges, F.I.G.M.
Conde, C.A.N.
Experimental Ion Mobility measurements in Ne-CO$_2$ and CO$_2$-N$_2$ mixtures
title Experimental Ion Mobility measurements in Ne-CO$_2$ and CO$_2$-N$_2$ mixtures
title_full Experimental Ion Mobility measurements in Ne-CO$_2$ and CO$_2$-N$_2$ mixtures
title_fullStr Experimental Ion Mobility measurements in Ne-CO$_2$ and CO$_2$-N$_2$ mixtures
title_full_unstemmed Experimental Ion Mobility measurements in Ne-CO$_2$ and CO$_2$-N$_2$ mixtures
title_short Experimental Ion Mobility measurements in Ne-CO$_2$ and CO$_2$-N$_2$ mixtures
title_sort experimental ion mobility measurements in ne-co$_2$ and co$_2$-n$_2$ mixtures
topic XX
url https://dx.doi.org/10.1088/1748-0221/11/05/P05005
http://cds.cern.ch/record/2255747
work_keys_str_mv AT encarnacaopmcc experimentalionmobilitymeasurementsinneco2andco2n2mixtures
AT cortezafv experimentalionmobilitymeasurementsinneco2andco2n2mixtures
AT veenhofr experimentalionmobilitymeasurementsinneco2andco2n2mixtures
AT nevespnb experimentalionmobilitymeasurementsinneco2andco2n2mixtures
AT santosfp experimentalionmobilitymeasurementsinneco2andco2n2mixtures
AT trindadeamf experimentalionmobilitymeasurementsinneco2andco2n2mixtures
AT borgesfigm experimentalionmobilitymeasurementsinneco2andco2n2mixtures
AT condecan experimentalionmobilitymeasurementsinneco2andco2n2mixtures