Cargando…
Experimental Ion Mobility measurements in Ne-CO$_2$ and CO$_2$-N$_2$ mixtures
In this paper we present the experimental results for the mobility, K0, of ions in neon-carbon dioxide (Ne-CO2) and carbon dioxide-nitrogen (CO2-N2) gaseous mixtures for total pressures ranging from 8–12 Torr, reduced electric fields in the 10–25 Td range, at room temperature. Regarding the Ne-CO2 m...
Autores principales: | , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2016
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/1748-0221/11/05/P05005 http://cds.cern.ch/record/2255747 |
_version_ | 1780953709946077184 |
---|---|
author | Encarnação, P.M.C.C. Cortez, A.F.V. Veenhof, R. Neves, P.N.B. Santos, F.P. Trindade, A.M.F. Borges, F.I.G.M. Conde, C.A.N. |
author_facet | Encarnação, P.M.C.C. Cortez, A.F.V. Veenhof, R. Neves, P.N.B. Santos, F.P. Trindade, A.M.F. Borges, F.I.G.M. Conde, C.A.N. |
author_sort | Encarnação, P.M.C.C. |
collection | CERN |
description | In this paper we present the experimental results for the mobility, K0, of ions in neon-carbon dioxide (Ne-CO2) and carbon dioxide-nitrogen (CO2-N2) gaseous mixtures for total pressures ranging from 8–12 Torr, reduced electric fields in the 10–25 Td range, at room temperature. Regarding the Ne-CO2 mixture only one peak was observed for CO2 concentrations above 25%, which has been identified as an ion originated in CO2, while below 25% of CO2 a second-small peak appears at the left side of the main peak, which has been attributed to impurities. The mobility values for the main peak range between 3.51 ± 0.05 and 1.07 ± 0.01 cm2V−1s−1 in the 10%-99% interval of CO2, and from 4.61 ± 0.19 to 3.00 ± 0.09 cm2V−1s−1 for the second peak observed (10%–25% of CO2). For the CO2-N2, the time-of-arrival spectra displayed only one peak for CO2 concentrations above 10%, which was attributed to ions originated in CO2, namely CO2+(CO2), with a second peak appearing for CO2 concentrations below 10%. This second peak, with higher mobility, was attributed to CO2+ ions. The mobility values of the main peak range between 2.11 ± 0.04 and 1.10 ± 0.03 cm2V−1s−1 in the 1%–99% interval of CO2, while the second peak's from 2.26 ± 0.02 and 1.95 ± 0.04 cm2V−1s−1 (1%–10% of CO2). The inverse of the mobility displays an aproximately linear dependence on the CO2 concentration in the mixture. |
id | cern-2255747 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2016 |
record_format | invenio |
spelling | cern-22557472022-08-10T12:45:11Zdoi:10.1088/1748-0221/11/05/P05005http://cds.cern.ch/record/2255747engEncarnação, P.M.C.C.Cortez, A.F.V.Veenhof, R.Neves, P.N.B.Santos, F.P.Trindade, A.M.F.Borges, F.I.G.M.Conde, C.A.N.Experimental Ion Mobility measurements in Ne-CO$_2$ and CO$_2$-N$_2$ mixturesXXIn this paper we present the experimental results for the mobility, K0, of ions in neon-carbon dioxide (Ne-CO2) and carbon dioxide-nitrogen (CO2-N2) gaseous mixtures for total pressures ranging from 8–12 Torr, reduced electric fields in the 10–25 Td range, at room temperature. Regarding the Ne-CO2 mixture only one peak was observed for CO2 concentrations above 25%, which has been identified as an ion originated in CO2, while below 25% of CO2 a second-small peak appears at the left side of the main peak, which has been attributed to impurities. The mobility values for the main peak range between 3.51 ± 0.05 and 1.07 ± 0.01 cm2V−1s−1 in the 10%-99% interval of CO2, and from 4.61 ± 0.19 to 3.00 ± 0.09 cm2V−1s−1 for the second peak observed (10%–25% of CO2). For the CO2-N2, the time-of-arrival spectra displayed only one peak for CO2 concentrations above 10%, which was attributed to ions originated in CO2, namely CO2+(CO2), with a second peak appearing for CO2 concentrations below 10%. This second peak, with higher mobility, was attributed to CO2+ ions. The mobility values of the main peak range between 2.11 ± 0.04 and 1.10 ± 0.03 cm2V−1s−1 in the 1%–99% interval of CO2, while the second peak's from 2.26 ± 0.02 and 1.95 ± 0.04 cm2V−1s−1 (1%–10% of CO2). The inverse of the mobility displays an aproximately linear dependence on the CO2 concentration in the mixture.oai:cds.cern.ch:22557472016 |
spellingShingle | XX Encarnação, P.M.C.C. Cortez, A.F.V. Veenhof, R. Neves, P.N.B. Santos, F.P. Trindade, A.M.F. Borges, F.I.G.M. Conde, C.A.N. Experimental Ion Mobility measurements in Ne-CO$_2$ and CO$_2$-N$_2$ mixtures |
title | Experimental Ion Mobility measurements in Ne-CO$_2$ and CO$_2$-N$_2$ mixtures |
title_full | Experimental Ion Mobility measurements in Ne-CO$_2$ and CO$_2$-N$_2$ mixtures |
title_fullStr | Experimental Ion Mobility measurements in Ne-CO$_2$ and CO$_2$-N$_2$ mixtures |
title_full_unstemmed | Experimental Ion Mobility measurements in Ne-CO$_2$ and CO$_2$-N$_2$ mixtures |
title_short | Experimental Ion Mobility measurements in Ne-CO$_2$ and CO$_2$-N$_2$ mixtures |
title_sort | experimental ion mobility measurements in ne-co$_2$ and co$_2$-n$_2$ mixtures |
topic | XX |
url | https://dx.doi.org/10.1088/1748-0221/11/05/P05005 http://cds.cern.ch/record/2255747 |
work_keys_str_mv | AT encarnacaopmcc experimentalionmobilitymeasurementsinneco2andco2n2mixtures AT cortezafv experimentalionmobilitymeasurementsinneco2andco2n2mixtures AT veenhofr experimentalionmobilitymeasurementsinneco2andco2n2mixtures AT nevespnb experimentalionmobilitymeasurementsinneco2andco2n2mixtures AT santosfp experimentalionmobilitymeasurementsinneco2andco2n2mixtures AT trindadeamf experimentalionmobilitymeasurementsinneco2andco2n2mixtures AT borgesfigm experimentalionmobilitymeasurementsinneco2andco2n2mixtures AT condecan experimentalionmobilitymeasurementsinneco2andco2n2mixtures |