Cargando…

State of the art timing in TOF-PET detectors with LuAG, GAGG and L(Y)SO scintillators of various sizes coupled to FBK-SiPMs

Time of flight (TOF) in positron emission tomography (PET) has experienced a revival of interest after its first introduction in the eighties. This is due to a significant progress in solid state photodetectors (SiPMs) and newly developed scintillators (LSO and its derivatives). Latest developments...

Descripción completa

Detalles Bibliográficos
Autores principales: Gundacker, S., Acerbi, F., Auffray, E., Ferri, A., Gola, A., Nemallapudi, M.V., Paternoster, G., Piemonte, C., Lecoq, P.
Lenguaje:eng
Publicado: 2016
Materias:
XX
Acceso en línea:https://dx.doi.org/10.1088/1748-0221/11/08/P08008
http://cds.cern.ch/record/2255754
_version_ 1780953710159986688
author Gundacker, S.
Acerbi, F.
Auffray, E.
Ferri, A.
Gola, A.
Nemallapudi, M.V.
Paternoster, G.
Piemonte, C.
Lecoq, P.
author_facet Gundacker, S.
Acerbi, F.
Auffray, E.
Ferri, A.
Gola, A.
Nemallapudi, M.V.
Paternoster, G.
Piemonte, C.
Lecoq, P.
author_sort Gundacker, S.
collection CERN
description Time of flight (TOF) in positron emission tomography (PET) has experienced a revival of interest after its first introduction in the eighties. This is due to a significant progress in solid state photodetectors (SiPMs) and newly developed scintillators (LSO and its derivatives). Latest developments at Fondazione Bruno Kessler (FBK) lead to the NUV-HD SiPM with a very high photon detection efficiency of around 55%. Despite the large area of 4×4 mm2 it achieves a good single photon time resolution (SPTR) of 180±5ps FWHM. Coincidence time resolution (CTR) measurements using LSO:Ce codoped with Ca scintillators yield best values of 73±2ps FWHM for 2×2×3 mm3 and 117±3ps for 2×2×20 mm3 crystal sizes. Increasing the crystal cross-section from 2×2 mm2 to 3×3 mm2 a non negligible CTR deterioration of approximately 7ps FWHM is observed. Measurements with LSO:Ce codoped Ca and LYSO:Ce scintillators with various cross-sections (1×1 mm2 - 4×4 mm2) and lengths (3mm - 30mm) will be a basis for discussing on how the crystal geometry affects timing in TOF-PET. Special attention is given to SiPM parameters, e.g. SPTR and optical crosstalk, and their measured dependency on the crystal cross-section. Additionally, CTR measurements with LuAG:Ce, LuAG:Pr and GGAG:Ce samples are presented and the results are interpreted in terms of their scintillation properties, e.g. rise time, decay time, light yield and emission spectra.
id cern-2255754
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling cern-22557542022-08-10T12:42:23Zdoi:10.1088/1748-0221/11/08/P08008http://cds.cern.ch/record/2255754engGundacker, S.Acerbi, F.Auffray, E.Ferri, A.Gola, A.Nemallapudi, M.V.Paternoster, G.Piemonte, C.Lecoq, P.State of the art timing in TOF-PET detectors with LuAG, GAGG and L(Y)SO scintillators of various sizes coupled to FBK-SiPMsXXTime of flight (TOF) in positron emission tomography (PET) has experienced a revival of interest after its first introduction in the eighties. This is due to a significant progress in solid state photodetectors (SiPMs) and newly developed scintillators (LSO and its derivatives). Latest developments at Fondazione Bruno Kessler (FBK) lead to the NUV-HD SiPM with a very high photon detection efficiency of around 55%. Despite the large area of 4×4 mm2 it achieves a good single photon time resolution (SPTR) of 180±5ps FWHM. Coincidence time resolution (CTR) measurements using LSO:Ce codoped with Ca scintillators yield best values of 73±2ps FWHM for 2×2×3 mm3 and 117±3ps for 2×2×20 mm3 crystal sizes. Increasing the crystal cross-section from 2×2 mm2 to 3×3 mm2 a non negligible CTR deterioration of approximately 7ps FWHM is observed. Measurements with LSO:Ce codoped Ca and LYSO:Ce scintillators with various cross-sections (1×1 mm2 - 4×4 mm2) and lengths (3mm - 30mm) will be a basis for discussing on how the crystal geometry affects timing in TOF-PET. Special attention is given to SiPM parameters, e.g. SPTR and optical crosstalk, and their measured dependency on the crystal cross-section. Additionally, CTR measurements with LuAG:Ce, LuAG:Pr and GGAG:Ce samples are presented and the results are interpreted in terms of their scintillation properties, e.g. rise time, decay time, light yield and emission spectra.oai:cds.cern.ch:22557542016
spellingShingle XX
Gundacker, S.
Acerbi, F.
Auffray, E.
Ferri, A.
Gola, A.
Nemallapudi, M.V.
Paternoster, G.
Piemonte, C.
Lecoq, P.
State of the art timing in TOF-PET detectors with LuAG, GAGG and L(Y)SO scintillators of various sizes coupled to FBK-SiPMs
title State of the art timing in TOF-PET detectors with LuAG, GAGG and L(Y)SO scintillators of various sizes coupled to FBK-SiPMs
title_full State of the art timing in TOF-PET detectors with LuAG, GAGG and L(Y)SO scintillators of various sizes coupled to FBK-SiPMs
title_fullStr State of the art timing in TOF-PET detectors with LuAG, GAGG and L(Y)SO scintillators of various sizes coupled to FBK-SiPMs
title_full_unstemmed State of the art timing in TOF-PET detectors with LuAG, GAGG and L(Y)SO scintillators of various sizes coupled to FBK-SiPMs
title_short State of the art timing in TOF-PET detectors with LuAG, GAGG and L(Y)SO scintillators of various sizes coupled to FBK-SiPMs
title_sort state of the art timing in tof-pet detectors with luag, gagg and l(y)so scintillators of various sizes coupled to fbk-sipms
topic XX
url https://dx.doi.org/10.1088/1748-0221/11/08/P08008
http://cds.cern.ch/record/2255754
work_keys_str_mv AT gundackers stateofthearttimingintofpetdetectorswithluaggaggandlysoscintillatorsofvarioussizescoupledtofbksipms
AT acerbif stateofthearttimingintofpetdetectorswithluaggaggandlysoscintillatorsofvarioussizescoupledtofbksipms
AT auffraye stateofthearttimingintofpetdetectorswithluaggaggandlysoscintillatorsofvarioussizescoupledtofbksipms
AT ferria stateofthearttimingintofpetdetectorswithluaggaggandlysoscintillatorsofvarioussizescoupledtofbksipms
AT golaa stateofthearttimingintofpetdetectorswithluaggaggandlysoscintillatorsofvarioussizescoupledtofbksipms
AT nemallapudimv stateofthearttimingintofpetdetectorswithluaggaggandlysoscintillatorsofvarioussizescoupledtofbksipms
AT paternosterg stateofthearttimingintofpetdetectorswithluaggaggandlysoscintillatorsofvarioussizescoupledtofbksipms
AT piemontec stateofthearttimingintofpetdetectorswithluaggaggandlysoscintillatorsofvarioussizescoupledtofbksipms
AT lecoqp stateofthearttimingintofpetdetectorswithluaggaggandlysoscintillatorsofvarioussizescoupledtofbksipms