Cargando…

Development and evaluation of a practical method to measure the Depth of Interaction function for a single side readout PET detector

In small animal and organ dedicated PET scanners, the knowledge of depth of interaction (DOI) of the gamma ray along the main axis of the scintillator is a fundamental information in order to avoid parallax error and to achieve high performances in terms of spatial resolution. Recently we developed...

Descripción completa

Detalles Bibliográficos
Autores principales: Stringhini, G., Pizzichemi, M., Ghezzi, A., Stojkovic, A., Paganoni, M., Auffray, E.
Lenguaje:eng
Publicado: 2016
Materias:
XX
Acceso en línea:https://dx.doi.org/10.1088/1748-0221/11/11/P11014
http://cds.cern.ch/record/2255888
_version_ 1780953714241044480
author Stringhini, G.
Pizzichemi, M.
Ghezzi, A.
Stojkovic, A.
Paganoni, M.
Auffray, E.
author_facet Stringhini, G.
Pizzichemi, M.
Ghezzi, A.
Stojkovic, A.
Paganoni, M.
Auffray, E.
author_sort Stringhini, G.
collection CERN
description In small animal and organ dedicated PET scanners, the knowledge of depth of interaction (DOI) of the gamma ray along the main axis of the scintillator is a fundamental information in order to avoid parallax error and to achieve high performances in terms of spatial resolution. Recently we developed a new method to obtain the DOI function for a single side readout PET module, recirculating the scintillation light in the matrix by means of a mirror placed on top of the module. In a complete PET scanner, periodical DOI calibrations have to be performed to prevent time dependent miscalibrations and performance degradations. The current DOI calibration relies on a coincidence system between the module and an external scintillator to provide a priori the DOI information and it is clearly not feasible in a real system without unpractical disassemblies of the scanner. In this paper we develop instead a fast and precise calibration method based on uniform irradiation of the scintillators. Three irradiation modalities are presented, in particular one where the source is placed on top of the module, one with the source placed on one side of the module and one that exploits the internal radioactivity of the scintillator. The three different procedures are evaluated and the calibration method is validated by comparing the information provided by the coincidence setup.
id cern-2255888
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling cern-22558882022-08-10T12:43:28Zdoi:10.1088/1748-0221/11/11/P11014http://cds.cern.ch/record/2255888engStringhini, G.Pizzichemi, M.Ghezzi, A.Stojkovic, A.Paganoni, M.Auffray, E.Development and evaluation of a practical method to measure the Depth of Interaction function for a single side readout PET detectorXXIn small animal and organ dedicated PET scanners, the knowledge of depth of interaction (DOI) of the gamma ray along the main axis of the scintillator is a fundamental information in order to avoid parallax error and to achieve high performances in terms of spatial resolution. Recently we developed a new method to obtain the DOI function for a single side readout PET module, recirculating the scintillation light in the matrix by means of a mirror placed on top of the module. In a complete PET scanner, periodical DOI calibrations have to be performed to prevent time dependent miscalibrations and performance degradations. The current DOI calibration relies on a coincidence system between the module and an external scintillator to provide a priori the DOI information and it is clearly not feasible in a real system without unpractical disassemblies of the scanner. In this paper we develop instead a fast and precise calibration method based on uniform irradiation of the scintillators. Three irradiation modalities are presented, in particular one where the source is placed on top of the module, one with the source placed on one side of the module and one that exploits the internal radioactivity of the scintillator. The three different procedures are evaluated and the calibration method is validated by comparing the information provided by the coincidence setup.oai:cds.cern.ch:22558882016
spellingShingle XX
Stringhini, G.
Pizzichemi, M.
Ghezzi, A.
Stojkovic, A.
Paganoni, M.
Auffray, E.
Development and evaluation of a practical method to measure the Depth of Interaction function for a single side readout PET detector
title Development and evaluation of a practical method to measure the Depth of Interaction function for a single side readout PET detector
title_full Development and evaluation of a practical method to measure the Depth of Interaction function for a single side readout PET detector
title_fullStr Development and evaluation of a practical method to measure the Depth of Interaction function for a single side readout PET detector
title_full_unstemmed Development and evaluation of a practical method to measure the Depth of Interaction function for a single side readout PET detector
title_short Development and evaluation of a practical method to measure the Depth of Interaction function for a single side readout PET detector
title_sort development and evaluation of a practical method to measure the depth of interaction function for a single side readout pet detector
topic XX
url https://dx.doi.org/10.1088/1748-0221/11/11/P11014
http://cds.cern.ch/record/2255888
work_keys_str_mv AT stringhinig developmentandevaluationofapracticalmethodtomeasurethedepthofinteractionfunctionforasinglesidereadoutpetdetector
AT pizzichemim developmentandevaluationofapracticalmethodtomeasurethedepthofinteractionfunctionforasinglesidereadoutpetdetector
AT ghezzia developmentandevaluationofapracticalmethodtomeasurethedepthofinteractionfunctionforasinglesidereadoutpetdetector
AT stojkovica developmentandevaluationofapracticalmethodtomeasurethedepthofinteractionfunctionforasinglesidereadoutpetdetector
AT paganonim developmentandevaluationofapracticalmethodtomeasurethedepthofinteractionfunctionforasinglesidereadoutpetdetector
AT auffraye developmentandevaluationofapracticalmethodtomeasurethedepthofinteractionfunctionforasinglesidereadoutpetdetector