Alignment of CT-PPS detectors in 2016, before TS2

This note presents the first alignment of the CMS-TOTEM Precision Proton Spectrometer (CT-PPS) using the data from before Technical Stop 2 (TS2), 2016. This new procedure involves two stages. In the first one, data from a special calibration fill are used. In this fill, both horizontal and vertical...

Descripción completa

Detalles Bibliográficos
Autor principal: Kaspar, J
Lenguaje:eng
Publicado: 2017
Acceso en línea:http://cds.cern.ch/record/2256296
_version_ 1780953726014455808
author Kaspar, J
author_facet Kaspar, J
author_sort Kaspar, J
collection CERN
description This note presents the first alignment of the CMS-TOTEM Precision Proton Spectrometer (CT-PPS) using the data from before Technical Stop 2 (TS2), 2016. This new procedure involves two stages. In the first one, data from a special calibration fill are used. In this fill, both horizontal and vertical Roman Pots (RPs) were inserted very close to the beam. In the second stage, hit distributions from physics fills (with only horizontal RPs inserted) are matched to the previously aligned reference from the calibration fill. The alignment and optics calibration is verified by reconstructing consistent $\xi$ spectra from different RPs and LHC fills.
id cern-2256296
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2017
record_format invenio
spelling cern-22562962019-09-30T06:29:59Zhttp://cds.cern.ch/record/2256296engKaspar, JAlignment of CT-PPS detectors in 2016, before TS2This note presents the first alignment of the CMS-TOTEM Precision Proton Spectrometer (CT-PPS) using the data from before Technical Stop 2 (TS2), 2016. This new procedure involves two stages. In the first one, data from a special calibration fill are used. In this fill, both horizontal and vertical Roman Pots (RPs) were inserted very close to the beam. In the second stage, hit distributions from physics fills (with only horizontal RPs inserted) are matched to the previously aligned reference from the calibration fill. The alignment and optics calibration is verified by reconstructing consistent $\xi$ spectra from different RPs and LHC fills.CERN-TOTEM-NOTE-2017-001oai:cds.cern.ch:22562962017-03-20
spellingShingle Kaspar, J
Alignment of CT-PPS detectors in 2016, before TS2
title Alignment of CT-PPS detectors in 2016, before TS2
title_full Alignment of CT-PPS detectors in 2016, before TS2
title_fullStr Alignment of CT-PPS detectors in 2016, before TS2
title_full_unstemmed Alignment of CT-PPS detectors in 2016, before TS2
title_short Alignment of CT-PPS detectors in 2016, before TS2
title_sort alignment of ct-pps detectors in 2016, before ts2
url http://cds.cern.ch/record/2256296
work_keys_str_mv AT kasparj alignmentofctppsdetectorsin2016beforets2