Cargando…

Development of ATLAS Liquid Argon Calorimeter Readout Electronics for the HL-LHC

The LHC high-luminosity upgrade in 2024-2026 requires the associated detectors to operate at luminosities about 5-7 times larger than assumed in their original design. The pile-up is expected to increase to up to 200 events per proton bunch-crossing. To be able to retain interesting physics events e...

Descripción completa

Detalles Bibliográficos
Autor principal: Madysa, Nico
Lenguaje:eng
Publicado: 2017
Materias:
Acceso en línea:http://cds.cern.ch/record/2272175
_version_ 1780954914955984896
author Madysa, Nico
author_facet Madysa, Nico
author_sort Madysa, Nico
collection CERN
description The LHC high-luminosity upgrade in 2024-2026 requires the associated detectors to operate at luminosities about 5-7 times larger than assumed in their original design. The pile-up is expected to increase to up to 200 events per proton bunch-crossing. To be able to retain interesting physics events even at rather low transverse energy scales, increased trigger rates are foreseen for the ATLAS detector. At the hardware selection stage acceptance rates of 1 MHz are planned, combined with longer latencies up to 60 micro-seconds in order to read out the necessary data from all detector channels. Under these conditions, the current readout of the ATLAS Liquid Argon (LAr) Calorimeters does not provide sufficient buffering and bandwidth capabilities. Furthermore, the expected total radiation doses are beyond the qualification range of the current front-end electronics. For these reasons a replacement of the LAr front-end and back-end readout system is foreseen for all 182,500 readout channels, with the exception of the cold pre-amplifier and summing devices of the hadronic LAr Calorimeter. The new low-power electronics must be able to capture the triangular detector pulses of about 400-600 nano-seconds length with signal currents up to 10 mA and a dynamic range of 16 bit. Different technologies to meet these requirements are under evaluation: A preamplifier in 130nm CMOS technology with two gain stages can cover the desired dynamic range while meeting the required noise levels and non-linearity values. Alternatively, developments of pre-amplifier, shaper as well as ADCs are performed in 65 nm CMOS technology. Due to the lower voltage range, 2-gain and 4-gain designs of the analog part are studied with programmable peaking time to optimize the noise level in presence of signal pile-up. Radiation-hard, 14 bit ADC operating at 40 or 80 MHz are also being studied. Results from performance-simulation of the calorimeter readout system for the different options and results from design studies and first tests of the components will be presented.
id cern-2272175
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2017
record_format invenio
spelling cern-22721752019-09-30T06:29:59Zhttp://cds.cern.ch/record/2272175engMadysa, NicoDevelopment of ATLAS Liquid Argon Calorimeter Readout Electronics for the HL-LHCParticle Physics - ExperimentThe LHC high-luminosity upgrade in 2024-2026 requires the associated detectors to operate at luminosities about 5-7 times larger than assumed in their original design. The pile-up is expected to increase to up to 200 events per proton bunch-crossing. To be able to retain interesting physics events even at rather low transverse energy scales, increased trigger rates are foreseen for the ATLAS detector. At the hardware selection stage acceptance rates of 1 MHz are planned, combined with longer latencies up to 60 micro-seconds in order to read out the necessary data from all detector channels. Under these conditions, the current readout of the ATLAS Liquid Argon (LAr) Calorimeters does not provide sufficient buffering and bandwidth capabilities. Furthermore, the expected total radiation doses are beyond the qualification range of the current front-end electronics. For these reasons a replacement of the LAr front-end and back-end readout system is foreseen for all 182,500 readout channels, with the exception of the cold pre-amplifier and summing devices of the hadronic LAr Calorimeter. The new low-power electronics must be able to capture the triangular detector pulses of about 400-600 nano-seconds length with signal currents up to 10 mA and a dynamic range of 16 bit. Different technologies to meet these requirements are under evaluation: A preamplifier in 130nm CMOS technology with two gain stages can cover the desired dynamic range while meeting the required noise levels and non-linearity values. Alternatively, developments of pre-amplifier, shaper as well as ADCs are performed in 65 nm CMOS technology. Due to the lower voltage range, 2-gain and 4-gain designs of the analog part are studied with programmable peaking time to optimize the noise level in presence of signal pile-up. Radiation-hard, 14 bit ADC operating at 40 or 80 MHz are also being studied. Results from performance-simulation of the calorimeter readout system for the different options and results from design studies and first tests of the components will be presented.ATL-LARG-SLIDE-2017-399oai:cds.cern.ch:22721752017-06-29
spellingShingle Particle Physics - Experiment
Madysa, Nico
Development of ATLAS Liquid Argon Calorimeter Readout Electronics for the HL-LHC
title Development of ATLAS Liquid Argon Calorimeter Readout Electronics for the HL-LHC
title_full Development of ATLAS Liquid Argon Calorimeter Readout Electronics for the HL-LHC
title_fullStr Development of ATLAS Liquid Argon Calorimeter Readout Electronics for the HL-LHC
title_full_unstemmed Development of ATLAS Liquid Argon Calorimeter Readout Electronics for the HL-LHC
title_short Development of ATLAS Liquid Argon Calorimeter Readout Electronics for the HL-LHC
title_sort development of atlas liquid argon calorimeter readout electronics for the hl-lhc
topic Particle Physics - Experiment
url http://cds.cern.ch/record/2272175
work_keys_str_mv AT madysanico developmentofatlasliquidargoncalorimeterreadoutelectronicsforthehllhc