Cargando…
CERN Summer Student Programme 2017 Report
This report describes the work done during my CERN Summer Student Programme 2017. A set-up has been implemented to perform studies on possible aging effects caused by different materials and eventually to validate new components for future application at the LHC gas systems. The effects are studie...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2017
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2278251 |
_version_ | 1780955360329203712 |
---|---|
author | Mari, Tomoo |
author_facet | Mari, Tomoo |
author_sort | Mari, Tomoo |
collection | CERN |
description | This report describes the work done during my CERN Summer Student Programme 2017. A set-up has been implemented to perform studies on possible aging effects caused by different materials and eventually to validate new components for future application at the LHC gas systems. The effects are studied with a Single Wire Proportional Chamber (SWPC), which is very sensitive to pollutants and gas mixture variations. In particular, we evaluate a new flow-meter (OMRON MEMS Mass Flow Sensor) and the effect of plastic pipe on detector gain and O$_2$ and H$_2$O variations. with Single Wire Proportional Chamber (SWPC). Chapter 1 describes the characterization of the SWPC. Chapter 2 focuses on the evaluation test of the flow-meter while Chapter shows the effects of the addition of a plastic pipe in the set-up. |
id | cern-2278251 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2017 |
record_format | invenio |
spelling | cern-22782512019-09-30T06:29:59Zhttp://cds.cern.ch/record/2278251engMari, TomooCERN Summer Student Programme 2017 ReportDetectors and Experimental TechniquesThis report describes the work done during my CERN Summer Student Programme 2017. A set-up has been implemented to perform studies on possible aging effects caused by different materials and eventually to validate new components for future application at the LHC gas systems. The effects are studied with a Single Wire Proportional Chamber (SWPC), which is very sensitive to pollutants and gas mixture variations. In particular, we evaluate a new flow-meter (OMRON MEMS Mass Flow Sensor) and the effect of plastic pipe on detector gain and O$_2$ and H$_2$O variations. with Single Wire Proportional Chamber (SWPC). Chapter 1 describes the characterization of the SWPC. Chapter 2 focuses on the evaluation test of the flow-meter while Chapter shows the effects of the addition of a plastic pipe in the set-up.CERN-STUDENTS-Note-2017-025oai:cds.cern.ch:22782512017-08-11 |
spellingShingle | Detectors and Experimental Techniques Mari, Tomoo CERN Summer Student Programme 2017 Report |
title | CERN Summer Student Programme 2017 Report |
title_full | CERN Summer Student Programme 2017 Report |
title_fullStr | CERN Summer Student Programme 2017 Report |
title_full_unstemmed | CERN Summer Student Programme 2017 Report |
title_short | CERN Summer Student Programme 2017 Report |
title_sort | cern summer student programme 2017 report |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/2278251 |
work_keys_str_mv | AT maritomoo cernsummerstudentprogramme2017report |