Cargando…

CERN Summer Student Programme 2017 Report

This report describes the work done during my CERN Summer Student Programme 2017. A set-up has been implemented to perform studies on possible aging effects caused by different materials and eventually to validate new components for future application at the LHC gas systems. The effects are studie...

Descripción completa

Detalles Bibliográficos
Autor principal: Mari, Tomoo
Lenguaje:eng
Publicado: 2017
Materias:
Acceso en línea:http://cds.cern.ch/record/2278251
_version_ 1780955360329203712
author Mari, Tomoo
author_facet Mari, Tomoo
author_sort Mari, Tomoo
collection CERN
description This report describes the work done during my CERN Summer Student Programme 2017. A set-up has been implemented to perform studies on possible aging effects caused by different materials and eventually to validate new components for future application at the LHC gas systems. The effects are studied with a Single Wire Proportional Chamber (SWPC), which is very sensitive to pollutants and gas mixture variations. In particular, we evaluate a new flow-meter (OMRON MEMS Mass Flow Sensor) and the effect of plastic pipe on detector gain and O$_2$ and H$_2$O variations. with Single Wire Proportional Chamber (SWPC). Chapter 1 describes the characterization of the SWPC. Chapter 2 focuses on the evaluation test of the flow-meter while Chapter shows the effects of the addition of a plastic pipe in the set-up.
id cern-2278251
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2017
record_format invenio
spelling cern-22782512019-09-30T06:29:59Zhttp://cds.cern.ch/record/2278251engMari, TomooCERN Summer Student Programme 2017 ReportDetectors and Experimental TechniquesThis report describes the work done during my CERN Summer Student Programme 2017. A set-up has been implemented to perform studies on possible aging effects caused by different materials and eventually to validate new components for future application at the LHC gas systems. The effects are studied with a Single Wire Proportional Chamber (SWPC), which is very sensitive to pollutants and gas mixture variations. In particular, we evaluate a new flow-meter (OMRON MEMS Mass Flow Sensor) and the effect of plastic pipe on detector gain and O$_2$ and H$_2$O variations. with Single Wire Proportional Chamber (SWPC). Chapter 1 describes the characterization of the SWPC. Chapter 2 focuses on the evaluation test of the flow-meter while Chapter shows the effects of the addition of a plastic pipe in the set-up.CERN-STUDENTS-Note-2017-025oai:cds.cern.ch:22782512017-08-11
spellingShingle Detectors and Experimental Techniques
Mari, Tomoo
CERN Summer Student Programme 2017 Report
title CERN Summer Student Programme 2017 Report
title_full CERN Summer Student Programme 2017 Report
title_fullStr CERN Summer Student Programme 2017 Report
title_full_unstemmed CERN Summer Student Programme 2017 Report
title_short CERN Summer Student Programme 2017 Report
title_sort cern summer student programme 2017 report
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/2278251
work_keys_str_mv AT maritomoo cernsummerstudentprogramme2017report