Cargando…

Analysis of Time Resolution in HGCAL Testbeam

Using data from a 250 GeV electron run during the November 2016 HGCAL testbeam, the time resolution of the High Granularity hadronic endcap Calorimeter, HGCAL, was investigated, looking at the seven innermost Si cells, and using them as reference timers for each other. Cuts in the data was applied...

Descripción completa

Detalles Bibliográficos
Autor principal: Steentoft, Jonas
Lenguaje:eng
Publicado: 2017
Materias:
Acceso en línea:http://cds.cern.ch/record/2280986
_version_ 1780955552122142720
author Steentoft, Jonas
author_facet Steentoft, Jonas
author_sort Steentoft, Jonas
collection CERN
description Using data from a 250 GeV electron run during the November 2016 HGCAL testbeam, the time resolution of the High Granularity hadronic endcap Calorimeter, HGCAL, was investigated, looking at the seven innermost Si cells, and using them as reference timers for each other. Cuts in the data was applied based on signal amplitude,$0.05 \hspace{1mm} V < A < 0.45 \hspace{1mm} V$, position of incoming beam particle,$0 \hspace{1mm} mm < TDCx < 22\hspace{1mm} mm$ and $-7\hspace{1mm} mm <TDCy < 11\hspace{1mm} mm$ and size of the time difference between two cells, $\vert t_1 - t_2 \vert < 200 \hspace{1mm} ps.$ Timewalk corrections, wrt in-cell amplitude, were applied to the cut data, with the Photek as reference.\\ Gaussian functions were fitted to the corrected $\Delta t$ distributions, and a time resolution of $15-50$ $ps$ was obtained, depending on which two cells were compared, and how the low-statistics cut were placed. We also confirmed a slight correlation between time resolution and distance between the two cells compared. \end{abstract}
id cern-2280986
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2017
record_format invenio
spelling cern-22809862019-09-30T06:29:59Zhttp://cds.cern.ch/record/2280986engSteentoft, JonasAnalysis of Time Resolution in HGCAL TestbeamDetectors and Experimental Techniques Using data from a 250 GeV electron run during the November 2016 HGCAL testbeam, the time resolution of the High Granularity hadronic endcap Calorimeter, HGCAL, was investigated, looking at the seven innermost Si cells, and using them as reference timers for each other. Cuts in the data was applied based on signal amplitude,$0.05 \hspace{1mm} V < A < 0.45 \hspace{1mm} V$, position of incoming beam particle,$0 \hspace{1mm} mm < TDCx < 22\hspace{1mm} mm$ and $-7\hspace{1mm} mm <TDCy < 11\hspace{1mm} mm$ and size of the time difference between two cells, $\vert t_1 - t_2 \vert < 200 \hspace{1mm} ps.$ Timewalk corrections, wrt in-cell amplitude, were applied to the cut data, with the Photek as reference.\\ Gaussian functions were fitted to the corrected $\Delta t$ distributions, and a time resolution of $15-50$ $ps$ was obtained, depending on which two cells were compared, and how the low-statistics cut were placed. We also confirmed a slight correlation between time resolution and distance between the two cells compared. \end{abstract}CERN-STUDENTS-Note-2017-120oai:cds.cern.ch:22809862017-08-25
spellingShingle Detectors and Experimental Techniques
Steentoft, Jonas
Analysis of Time Resolution in HGCAL Testbeam
title Analysis of Time Resolution in HGCAL Testbeam
title_full Analysis of Time Resolution in HGCAL Testbeam
title_fullStr Analysis of Time Resolution in HGCAL Testbeam
title_full_unstemmed Analysis of Time Resolution in HGCAL Testbeam
title_short Analysis of Time Resolution in HGCAL Testbeam
title_sort analysis of time resolution in hgcal testbeam
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/2280986
work_keys_str_mv AT steentoftjonas analysisoftimeresolutioninhgcaltestbeam