Cargando…
Finding Multiple Peaks Signal in Fast Beam Conditions Monitor (BCM1F)
Fast Beam Conditions Monitor (BCM1F) is diamond and silicon sensors based luminometer of CMS detector. The methods of finding multiple peaks signal in BCM1F is shown. Multiple peaks signal found at signal with width between 60 ns - 300 ns. Double peaks are counted as single hit in the constant thres...
Autores principales: | , |
---|---|
Lenguaje: | eng |
Publicado: |
2017
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2281096 |
_version_ | 1780955558490144768 |
---|---|
author | Bin Ab Maalek, Abu Ubaidah Amir Karacheban, Olena |
author_facet | Bin Ab Maalek, Abu Ubaidah Amir Karacheban, Olena |
author_sort | Bin Ab Maalek, Abu Ubaidah Amir |
collection | CERN |
description | Fast Beam Conditions Monitor (BCM1F) is diamond and silicon sensors based luminometer of CMS detector. The methods of finding multiple peaks signal in BCM1F is shown. Multiple peaks signal found at signal with width between 60 ns - 300 ns. Double peaks are counted as single hit in the constant threshold analysis and leads to underestimation in the luminosity. Therefore it should be estimated for different filling schemes and sensor types. The percentage of long width pulse in different sensor for different fill are calculated. About 30 \% long width pulse found in sCVD sensor, 12 \% in pCVD and no more than 1 \% for silicon sensor. |
id | cern-2281096 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2017 |
record_format | invenio |
spelling | cern-22810962019-09-30T06:29:59Zhttp://cds.cern.ch/record/2281096engBin Ab Maalek, Abu Ubaidah AmirKaracheban, OlenaFinding Multiple Peaks Signal in Fast Beam Conditions Monitor (BCM1F) Detectors and Experimental TechniquesFast Beam Conditions Monitor (BCM1F) is diamond and silicon sensors based luminometer of CMS detector. The methods of finding multiple peaks signal in BCM1F is shown. Multiple peaks signal found at signal with width between 60 ns - 300 ns. Double peaks are counted as single hit in the constant threshold analysis and leads to underestimation in the luminosity. Therefore it should be estimated for different filling schemes and sensor types. The percentage of long width pulse in different sensor for different fill are calculated. About 30 \% long width pulse found in sCVD sensor, 12 \% in pCVD and no more than 1 \% for silicon sensor.CERN-STUDENTS-Note-2017-135oai:cds.cern.ch:22810962017-08-28 |
spellingShingle | Detectors and Experimental Techniques Bin Ab Maalek, Abu Ubaidah Amir Karacheban, Olena Finding Multiple Peaks Signal in Fast Beam Conditions Monitor (BCM1F) |
title | Finding Multiple Peaks Signal in Fast Beam Conditions Monitor (BCM1F) |
title_full | Finding Multiple Peaks Signal in Fast Beam Conditions Monitor (BCM1F) |
title_fullStr | Finding Multiple Peaks Signal in Fast Beam Conditions Monitor (BCM1F) |
title_full_unstemmed | Finding Multiple Peaks Signal in Fast Beam Conditions Monitor (BCM1F) |
title_short | Finding Multiple Peaks Signal in Fast Beam Conditions Monitor (BCM1F) |
title_sort | finding multiple peaks signal in fast beam conditions monitor (bcm1f) |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/2281096 |
work_keys_str_mv | AT binabmaalekabuubaidahamir findingmultiplepeakssignalinfastbeamconditionsmonitorbcm1f AT karachebanolena findingmultiplepeakssignalinfastbeamconditionsmonitorbcm1f |