Cargando…

Finding Multiple Peaks Signal in Fast Beam Conditions Monitor (BCM1F)

Fast Beam Conditions Monitor (BCM1F) is diamond and silicon sensors based luminometer of CMS detector. The methods of finding multiple peaks signal in BCM1F is shown. Multiple peaks signal found at signal with width between 60 ns - 300 ns. Double peaks are counted as single hit in the constant thres...

Descripción completa

Detalles Bibliográficos
Autores principales: Bin Ab Maalek, Abu Ubaidah Amir, Karacheban, Olena
Lenguaje:eng
Publicado: 2017
Materias:
Acceso en línea:http://cds.cern.ch/record/2281096
_version_ 1780955558490144768
author Bin Ab Maalek, Abu Ubaidah Amir
Karacheban, Olena
author_facet Bin Ab Maalek, Abu Ubaidah Amir
Karacheban, Olena
author_sort Bin Ab Maalek, Abu Ubaidah Amir
collection CERN
description Fast Beam Conditions Monitor (BCM1F) is diamond and silicon sensors based luminometer of CMS detector. The methods of finding multiple peaks signal in BCM1F is shown. Multiple peaks signal found at signal with width between 60 ns - 300 ns. Double peaks are counted as single hit in the constant threshold analysis and leads to underestimation in the luminosity. Therefore it should be estimated for different filling schemes and sensor types. The percentage of long width pulse in different sensor for different fill are calculated. About 30 \% long width pulse found in sCVD sensor, 12 \% in pCVD and no more than 1 \% for silicon sensor.
id cern-2281096
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2017
record_format invenio
spelling cern-22810962019-09-30T06:29:59Zhttp://cds.cern.ch/record/2281096engBin Ab Maalek, Abu Ubaidah AmirKaracheban, OlenaFinding Multiple Peaks Signal in Fast Beam Conditions Monitor (BCM1F) Detectors and Experimental TechniquesFast Beam Conditions Monitor (BCM1F) is diamond and silicon sensors based luminometer of CMS detector. The methods of finding multiple peaks signal in BCM1F is shown. Multiple peaks signal found at signal with width between 60 ns - 300 ns. Double peaks are counted as single hit in the constant threshold analysis and leads to underestimation in the luminosity. Therefore it should be estimated for different filling schemes and sensor types. The percentage of long width pulse in different sensor for different fill are calculated. About 30 \% long width pulse found in sCVD sensor, 12 \% in pCVD and no more than 1 \% for silicon sensor.CERN-STUDENTS-Note-2017-135oai:cds.cern.ch:22810962017-08-28
spellingShingle Detectors and Experimental Techniques
Bin Ab Maalek, Abu Ubaidah Amir
Karacheban, Olena
Finding Multiple Peaks Signal in Fast Beam Conditions Monitor (BCM1F)
title Finding Multiple Peaks Signal in Fast Beam Conditions Monitor (BCM1F)
title_full Finding Multiple Peaks Signal in Fast Beam Conditions Monitor (BCM1F)
title_fullStr Finding Multiple Peaks Signal in Fast Beam Conditions Monitor (BCM1F)
title_full_unstemmed Finding Multiple Peaks Signal in Fast Beam Conditions Monitor (BCM1F)
title_short Finding Multiple Peaks Signal in Fast Beam Conditions Monitor (BCM1F)
title_sort finding multiple peaks signal in fast beam conditions monitor (bcm1f)
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/2281096
work_keys_str_mv AT binabmaalekabuubaidahamir findingmultiplepeakssignalinfastbeamconditionsmonitorbcm1f
AT karachebanolena findingmultiplepeakssignalinfastbeamconditionsmonitorbcm1f