Cargando…
Test Beam Measurements on Picosec Gaseous Detector.
In the Picosec project micro pattern gaseous detectors with a time resolution of some ten picoseconds are developed. The detectors are based on Micromegas detectors. With a cherenkov window and a photocathode the time jitter from different position of the primary ionization clusters can be substitut...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2017
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2281754 |
_version_ | 1780955592124268544 |
---|---|
author | Sohl, Lukas |
author_facet | Sohl, Lukas |
author_sort | Sohl, Lukas |
collection | CERN |
description | In the Picosec project micro pattern gaseous detectors with a time resolution of some ten picoseconds are developed. The detectors are based on Micromegas detectors. With a cherenkov window and a photocathode the time jitter from different position of the primary ionization clusters can be substituted. This reports describes the beam setup and measurements of different Picosec prototypes. A time resolution of under 30 ps has been measured during the test beam. This report gives an overview of my work as a Summer Student. I set up and operated a triple-GEM tracker and a trigger system for the beam. During the beam I measured different prototypes of Picosec detectors and analysed the data. |
id | cern-2281754 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2017 |
record_format | invenio |
spelling | cern-22817542019-09-30T06:29:59Zhttp://cds.cern.ch/record/2281754engSohl, LukasTest Beam Measurements on Picosec Gaseous Detector.Detectors and Experimental TechniquesIn the Picosec project micro pattern gaseous detectors with a time resolution of some ten picoseconds are developed. The detectors are based on Micromegas detectors. With a cherenkov window and a photocathode the time jitter from different position of the primary ionization clusters can be substituted. This reports describes the beam setup and measurements of different Picosec prototypes. A time resolution of under 30 ps has been measured during the test beam. This report gives an overview of my work as a Summer Student. I set up and operated a triple-GEM tracker and a trigger system for the beam. During the beam I measured different prototypes of Picosec detectors and analysed the data. CERN-STUDENTS-Note-2017-151oai:cds.cern.ch:22817542017-09-01 |
spellingShingle | Detectors and Experimental Techniques Sohl, Lukas Test Beam Measurements on Picosec Gaseous Detector. |
title | Test Beam Measurements on Picosec Gaseous Detector. |
title_full | Test Beam Measurements on Picosec Gaseous Detector. |
title_fullStr | Test Beam Measurements on Picosec Gaseous Detector. |
title_full_unstemmed | Test Beam Measurements on Picosec Gaseous Detector. |
title_short | Test Beam Measurements on Picosec Gaseous Detector. |
title_sort | test beam measurements on picosec gaseous detector. |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/2281754 |
work_keys_str_mv | AT sohllukas testbeammeasurementsonpicosecgaseousdetector |