Test Beam Measurements on Picosec Gaseous Detector.

In the Picosec project micro pattern gaseous detectors with a time resolution of some ten picoseconds are developed. The detectors are based on Micromegas detectors. With a cherenkov window and a photocathode the time jitter from different position of the primary ionization clusters can be substitut...

Descripción completa

Detalles Bibliográficos
Autor principal: Sohl, Lukas
Lenguaje:eng
Publicado: 2017
Materias:
Acceso en línea:http://cds.cern.ch/record/2281754
_version_ 1780955592124268544
author Sohl, Lukas
author_facet Sohl, Lukas
author_sort Sohl, Lukas
collection CERN
description In the Picosec project micro pattern gaseous detectors with a time resolution of some ten picoseconds are developed. The detectors are based on Micromegas detectors. With a cherenkov window and a photocathode the time jitter from different position of the primary ionization clusters can be substituted. This reports describes the beam setup and measurements of different Picosec prototypes. A time resolution of under 30 ps has been measured during the test beam. This report gives an overview of my work as a Summer Student. I set up and operated a triple-GEM tracker and a trigger system for the beam. During the beam I measured different prototypes of Picosec detectors and analysed the data.
id cern-2281754
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2017
record_format invenio
spelling cern-22817542019-09-30T06:29:59Zhttp://cds.cern.ch/record/2281754engSohl, LukasTest Beam Measurements on Picosec Gaseous Detector.Detectors and Experimental TechniquesIn the Picosec project micro pattern gaseous detectors with a time resolution of some ten picoseconds are developed. The detectors are based on Micromegas detectors. With a cherenkov window and a photocathode the time jitter from different position of the primary ionization clusters can be substituted. This reports describes the beam setup and measurements of different Picosec prototypes. A time resolution of under 30 ps has been measured during the test beam. This report gives an overview of my work as a Summer Student. I set up and operated a triple-GEM tracker and a trigger system for the beam. During the beam I measured different prototypes of Picosec detectors and analysed the data. CERN-STUDENTS-Note-2017-151oai:cds.cern.ch:22817542017-09-01
spellingShingle Detectors and Experimental Techniques
Sohl, Lukas
Test Beam Measurements on Picosec Gaseous Detector.
title Test Beam Measurements on Picosec Gaseous Detector.
title_full Test Beam Measurements on Picosec Gaseous Detector.
title_fullStr Test Beam Measurements on Picosec Gaseous Detector.
title_full_unstemmed Test Beam Measurements on Picosec Gaseous Detector.
title_short Test Beam Measurements on Picosec Gaseous Detector.
title_sort test beam measurements on picosec gaseous detector.
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/2281754
work_keys_str_mv AT sohllukas testbeammeasurementsonpicosecgaseousdetector