Cargando…
Muon Chamber Endcap Upgrade of the CMS Experiment with Gas Electron Multiplier (GEM) Detectors and their Performance
As the CERN LHC is heading towards a high luminosity phase a very high flux is expected in the endcaps of the CMS Detector. The presence of muons in collision events can be due to rare or new physics so it is important to maintain the high trigger efficiency of the CMS muon system. The CMS Collabora...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2017
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1007/978-3-319-73171-1_139 http://cds.cern.ch/record/2282911 |
_version_ | 1780955676795731968 |
---|---|
author | Gola, Mohit |
author_facet | Gola, Mohit |
author_sort | Gola, Mohit |
collection | CERN |
description | As the CERN LHC is heading towards a high luminosity phase a very high flux is expected in the endcaps of the CMS Detector. The presence of muons in collision events can be due to rare or new physics so it is important to maintain the high trigger efficiency of the CMS muon system. The CMS Collaboration has proposed to instrument the high-eta region (1.6 lt IetaI lt 2.2) of the muon endcaps with Gas Electron Multiplier (GEM) detectors, referred to as GE1/1 chambers, during the LS2. This technology will help in maintaining optimum trigger performance with maximum selection efficiency of muons even in a high flux environment. We describe plans for a Slice Test to installa few GE1/1 chambers covering 50 degrees in azimuthal angle within the CMS detector in 2017, with subsequent operation during the current Run 2 of the LHC. We show the performance of the GE1/1 chambers to be installed during the slice test, specifically GEM foil leakage currents, chamber gas volume integrity, high voltage circuit performance, and effective gain. To check the detection performance over the entire surface of the detector response uniformity is also measured. |
id | cern-2282911 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2017 |
record_format | invenio |
spelling | cern-22829112019-09-30T06:29:59Zdoi:10.1007/978-3-319-73171-1_139http://cds.cern.ch/record/2282911engGola, MohitMuon Chamber Endcap Upgrade of the CMS Experiment with Gas Electron Multiplier (GEM) Detectors and their PerformanceDetectors and Experimental TechniquesAs the CERN LHC is heading towards a high luminosity phase a very high flux is expected in the endcaps of the CMS Detector. The presence of muons in collision events can be due to rare or new physics so it is important to maintain the high trigger efficiency of the CMS muon system. The CMS Collaboration has proposed to instrument the high-eta region (1.6 lt IetaI lt 2.2) of the muon endcaps with Gas Electron Multiplier (GEM) detectors, referred to as GE1/1 chambers, during the LS2. This technology will help in maintaining optimum trigger performance with maximum selection efficiency of muons even in a high flux environment. We describe plans for a Slice Test to installa few GE1/1 chambers covering 50 degrees in azimuthal angle within the CMS detector in 2017, with subsequent operation during the current Run 2 of the LHC. We show the performance of the GE1/1 chambers to be installed during the slice test, specifically GEM foil leakage currents, chamber gas volume integrity, high voltage circuit performance, and effective gain. To check the detection performance over the entire surface of the detector response uniformity is also measured.CMS-CR-2017-084oai:cds.cern.ch:22829112017-02-27 |
spellingShingle | Detectors and Experimental Techniques Gola, Mohit Muon Chamber Endcap Upgrade of the CMS Experiment with Gas Electron Multiplier (GEM) Detectors and their Performance |
title | Muon Chamber Endcap Upgrade of the CMS Experiment with Gas Electron Multiplier (GEM) Detectors and their Performance |
title_full | Muon Chamber Endcap Upgrade of the CMS Experiment with Gas Electron Multiplier (GEM) Detectors and their Performance |
title_fullStr | Muon Chamber Endcap Upgrade of the CMS Experiment with Gas Electron Multiplier (GEM) Detectors and their Performance |
title_full_unstemmed | Muon Chamber Endcap Upgrade of the CMS Experiment with Gas Electron Multiplier (GEM) Detectors and their Performance |
title_short | Muon Chamber Endcap Upgrade of the CMS Experiment with Gas Electron Multiplier (GEM) Detectors and their Performance |
title_sort | muon chamber endcap upgrade of the cms experiment with gas electron multiplier (gem) detectors and their performance |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1007/978-3-319-73171-1_139 http://cds.cern.ch/record/2282911 |
work_keys_str_mv | AT golamohit muonchamberendcapupgradeofthecmsexperimentwithgaselectronmultipliergemdetectorsandtheirperformance |