Laser calibration of the ATLAS Tile Calorimeter

High performance stability of the ATLAS Tile calorimeter is achieved with a set of calibration procedures. One step of the calibration procedure is based on measurements of the response stability to laser excitation of the photomultipliers (PMTs) that are used to readout the calorimeter cells. A fac...

Descripción completa

Detalles Bibliográficos
Autor principal: Di Gregorio, Giulia
Lenguaje:eng
Publicado: 2017
Materias:
Acceso en línea:https://dx.doi.org/10.22323/1.314.0783
http://cds.cern.ch/record/2287036
_version_ 1780955994557251584
author Di Gregorio, Giulia
author_facet Di Gregorio, Giulia
author_sort Di Gregorio, Giulia
collection CERN
description High performance stability of the ATLAS Tile calorimeter is achieved with a set of calibration procedures. One step of the calibration procedure is based on measurements of the response stability to laser excitation of the photomultipliers (PMTs) that are used to readout the calorimeter cells. A facility to study in lab the PMT stability response is operating in the PISA-INFN laboratories since 2015. Goals of the tests in lab are to study the time evolution of the PMT response to reproduce and to understand the origin of the response drifts seen with the PMT mounted on the Tile calorimeter in its normal operation during LHC run I and run II.A new statistical approach was developed to measure the drift of the absolute gain. This approach was applied to both the ATLAS laser calibration data and to the data collected in the Pisa local laboratory. The preliminary results from these two studies are discussed.
id cern-2287036
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2017
record_format invenio
spelling cern-22870362021-05-03T07:54:05Zdoi:10.22323/1.314.0783http://cds.cern.ch/record/2287036engDi Gregorio, GiuliaLaser calibration of the ATLAS Tile CalorimeterParticle Physics - ExperimentHigh performance stability of the ATLAS Tile calorimeter is achieved with a set of calibration procedures. One step of the calibration procedure is based on measurements of the response stability to laser excitation of the photomultipliers (PMTs) that are used to readout the calorimeter cells. A facility to study in lab the PMT stability response is operating in the PISA-INFN laboratories since 2015. Goals of the tests in lab are to study the time evolution of the PMT response to reproduce and to understand the origin of the response drifts seen with the PMT mounted on the Tile calorimeter in its normal operation during LHC run I and run II.A new statistical approach was developed to measure the drift of the absolute gain. This approach was applied to both the ATLAS laser calibration data and to the data collected in the Pisa local laboratory. The preliminary results from these two studies are discussed.ATL-TILECAL-PROC-2017-017oai:cds.cern.ch:22870362017-10-04
spellingShingle Particle Physics - Experiment
Di Gregorio, Giulia
Laser calibration of the ATLAS Tile Calorimeter
title Laser calibration of the ATLAS Tile Calorimeter
title_full Laser calibration of the ATLAS Tile Calorimeter
title_fullStr Laser calibration of the ATLAS Tile Calorimeter
title_full_unstemmed Laser calibration of the ATLAS Tile Calorimeter
title_short Laser calibration of the ATLAS Tile Calorimeter
title_sort laser calibration of the atlas tile calorimeter
topic Particle Physics - Experiment
url https://dx.doi.org/10.22323/1.314.0783
http://cds.cern.ch/record/2287036
work_keys_str_mv AT digregoriogiulia lasercalibrationoftheatlastilecalorimeter