Cargando…

Operation and Performance of the ATLAS Level-1 Calorimeter and Topological Triggers in Run 2

In Run 2 at CERN's Large Hadron Collider, the ATLAS detector uses a two-level trigger system to reduce the event rate from the nominal collision rate of 40 MHz to the event storage rate of 1 kHz, while preserving interesting physics events. The first step of the trigger system, Level-1, reduces...

Descripción completa

Detalles Bibliográficos
Autor principal: Weber, Sebastian Mario
Lenguaje:eng
Publicado: 2017
Materias:
Acceso en línea:https://dx.doi.org/10.22323/1.314.0806
http://cds.cern.ch/record/2287401
_version_ 1780956020015628288
author Weber, Sebastian Mario
author_facet Weber, Sebastian Mario
author_sort Weber, Sebastian Mario
collection CERN
description In Run 2 at CERN's Large Hadron Collider, the ATLAS detector uses a two-level trigger system to reduce the event rate from the nominal collision rate of 40 MHz to the event storage rate of 1 kHz, while preserving interesting physics events. The first step of the trigger system, Level-1, reduces the event rate to 100 kHz within a latency of less than $2.5$ $\mu\text{s}$. One component of this system is the Level-1 Calorimeter Trigger (L1Calo), which uses coarse-granularity information from the electromagnetic and hadronic calorimeters to identify regions of interest corresponding to electrons, photons, taus, jets, and large amounts of transverse energy and missing transverse energy. In this contribution, we discuss improved features and performance of the L1Calo system in the challenging, high-luminosity conditions provided by the LHC in Run 2. A new dynamic pedestal correction algorithm reduces pile-up effects and the use of variable thresholds and isolation criteria for electromagnetic objects allows for optimal performance both at low and high energies.As the LHC exceeds its design luminosity, it is becoming even more critical to reduce event rates while preserving interesting physics. A new feature of the ATLAS Run 2 trigger system is the Level-1 Topological Trigger (L1Topo), which performs kinematic and angular selections within a latency of 200 ns. The physics motivation for L1Topo, as well as its implementation and performance in the ATLAS trigger system in Run 2, are discussed.
id cern-2287401
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2017
record_format invenio
spelling cern-22874012021-05-03T07:54:24Zdoi:10.22323/1.314.0806http://cds.cern.ch/record/2287401engWeber, Sebastian MarioOperation and Performance of the ATLAS Level-1 Calorimeter and Topological Triggers in Run 2Particle Physics - ExperimentIn Run 2 at CERN's Large Hadron Collider, the ATLAS detector uses a two-level trigger system to reduce the event rate from the nominal collision rate of 40 MHz to the event storage rate of 1 kHz, while preserving interesting physics events. The first step of the trigger system, Level-1, reduces the event rate to 100 kHz within a latency of less than $2.5$ $\mu\text{s}$. One component of this system is the Level-1 Calorimeter Trigger (L1Calo), which uses coarse-granularity information from the electromagnetic and hadronic calorimeters to identify regions of interest corresponding to electrons, photons, taus, jets, and large amounts of transverse energy and missing transverse energy. In this contribution, we discuss improved features and performance of the L1Calo system in the challenging, high-luminosity conditions provided by the LHC in Run 2. A new dynamic pedestal correction algorithm reduces pile-up effects and the use of variable thresholds and isolation criteria for electromagnetic objects allows for optimal performance both at low and high energies.As the LHC exceeds its design luminosity, it is becoming even more critical to reduce event rates while preserving interesting physics. A new feature of the ATLAS Run 2 trigger system is the Level-1 Topological Trigger (L1Topo), which performs kinematic and angular selections within a latency of 200 ns. The physics motivation for L1Topo, as well as its implementation and performance in the ATLAS trigger system in Run 2, are discussed.ATL-DAQ-PROC-2017-026oai:cds.cern.ch:22874012017-10-06
spellingShingle Particle Physics - Experiment
Weber, Sebastian Mario
Operation and Performance of the ATLAS Level-1 Calorimeter and Topological Triggers in Run 2
title Operation and Performance of the ATLAS Level-1 Calorimeter and Topological Triggers in Run 2
title_full Operation and Performance of the ATLAS Level-1 Calorimeter and Topological Triggers in Run 2
title_fullStr Operation and Performance of the ATLAS Level-1 Calorimeter and Topological Triggers in Run 2
title_full_unstemmed Operation and Performance of the ATLAS Level-1 Calorimeter and Topological Triggers in Run 2
title_short Operation and Performance of the ATLAS Level-1 Calorimeter and Topological Triggers in Run 2
title_sort operation and performance of the atlas level-1 calorimeter and topological triggers in run 2
topic Particle Physics - Experiment
url https://dx.doi.org/10.22323/1.314.0806
http://cds.cern.ch/record/2287401
work_keys_str_mv AT webersebastianmario operationandperformanceoftheatlaslevel1calorimeterandtopologicaltriggersinrun2