Study of signal discrimination for timing measurements

The timing detectors of the CMS-TOTEM Precision Proton Spectrometer (CT-PPS) are currently read out using discrete components, separated into three boards; the first board hosts the sensors and the amplifiers, the second one hosts the discriminators and the third is dedicated to the Time to Digital Co...

Descripción completa

Detalles Bibliográficos
Autor principal: Krepelkova, Marta
Lenguaje:eng
Publicado: 2017
Materias:
Acceso en línea:http://cds.cern.ch/record/2288112
Descripción
Sumario:The timing detectors of the CMS-TOTEM Precision Proton Spectrometer (CT-PPS) are currently read out using discrete components, separated into three boards; the first board hosts the sensors and the amplifiers, the second one hosts the discriminators and the third is dedicated to the Time to Digital Converter (TDC) and to the interface with the data acquisition system (DAQ). This work proposes a new front-end electronics for the timing detector, with sensors, amplifiers and discriminators integrated on the same board. We simulated an updated version of the amplifier together with a discriminator designed using commercial components. We decided to use an LVDS buffer as a discriminator, because of its cost, availability, speed and lo w power consumption. As a proof of concept, we used the LVDS input of an FPGA to discriminate signals produced by a detector prototype, using a radioactive source.