Cargando…
Design of the new front-end electronics for the readout of the upgraded CMS electromagnetic calorimeter for the HL-LHC
The Compact Muon Solenoid detector was originally designed to operate for about ten years, for LHC instantaneous luminosities up to $1 \cdot 10^{34}$ cm$^{-2}$ s$^{-1}$ and integrated luminosity of 500 fb$^{-1}$. The High Luminosity LHC will increase the instantaneous luminosity by about a factor of...
Autores principales: | , |
---|---|
Lenguaje: | eng |
Publicado: |
2017
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.22323/1.313.0106 http://cds.cern.ch/record/2290107 |
_version_ | 1780956287616417792 |
---|---|
author | Cometti, Simona Mazza, Gianni |
author_facet | Cometti, Simona Mazza, Gianni |
author_sort | Cometti, Simona |
collection | CERN |
description | The Compact Muon Solenoid detector was originally designed to operate for about ten years, for LHC instantaneous luminosities up to $1 \cdot 10^{34}$ cm$^{-2}$ s$^{-1}$ and integrated luminosity of 500 fb$^{-1}$. The High Luminosity LHC will increase the instantaneous luminosity by about a factor of 5 from current levels and CMS will accumulate an integrated luminosity of 3000 fb$^{-1}$ by about 2035. With such high luminosity the electromagnetic calorimeter of CMS will have to cope with a challenging increase in the number of interactions per bunch crossing and in radiation levels. The front-end readout electronics will be completely redesigned, with the goals of providing precision timing, low noise and added flexibility in the trigger system. It will use a faster pre-amplifier, increase the sampling frequency from 40 MS/s to 160 MS/s and implement a trigger system that resides entirely off-detector. |
id | cern-2290107 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2017 |
record_format | invenio |
spelling | cern-22901072019-09-30T06:29:59Zdoi:10.22323/1.313.0106http://cds.cern.ch/record/2290107engCometti, SimonaMazza, GianniDesign of the new front-end electronics for the readout of the upgraded CMS electromagnetic calorimeter for the HL-LHCDetectors and Experimental TechniquesThe Compact Muon Solenoid detector was originally designed to operate for about ten years, for LHC instantaneous luminosities up to $1 \cdot 10^{34}$ cm$^{-2}$ s$^{-1}$ and integrated luminosity of 500 fb$^{-1}$. The High Luminosity LHC will increase the instantaneous luminosity by about a factor of 5 from current levels and CMS will accumulate an integrated luminosity of 3000 fb$^{-1}$ by about 2035. With such high luminosity the electromagnetic calorimeter of CMS will have to cope with a challenging increase in the number of interactions per bunch crossing and in radiation levels. The front-end readout electronics will be completely redesigned, with the goals of providing precision timing, low noise and added flexibility in the trigger system. It will use a faster pre-amplifier, increase the sampling frequency from 40 MS/s to 160 MS/s and implement a trigger system that resides entirely off-detector.CMS-CR-2017-352oai:cds.cern.ch:22901072017-10-09 |
spellingShingle | Detectors and Experimental Techniques Cometti, Simona Mazza, Gianni Design of the new front-end electronics for the readout of the upgraded CMS electromagnetic calorimeter for the HL-LHC |
title | Design of the new front-end electronics for the readout of the upgraded CMS electromagnetic calorimeter for the HL-LHC |
title_full | Design of the new front-end electronics for the readout of the upgraded CMS electromagnetic calorimeter for the HL-LHC |
title_fullStr | Design of the new front-end electronics for the readout of the upgraded CMS electromagnetic calorimeter for the HL-LHC |
title_full_unstemmed | Design of the new front-end electronics for the readout of the upgraded CMS electromagnetic calorimeter for the HL-LHC |
title_short | Design of the new front-end electronics for the readout of the upgraded CMS electromagnetic calorimeter for the HL-LHC |
title_sort | design of the new front-end electronics for the readout of the upgraded cms electromagnetic calorimeter for the hl-lhc |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.22323/1.313.0106 http://cds.cern.ch/record/2290107 |
work_keys_str_mv | AT comettisimona designofthenewfrontendelectronicsforthereadoutoftheupgradedcmselectromagneticcalorimeterforthehllhc AT mazzagianni designofthenewfrontendelectronicsforthereadoutoftheupgradedcmselectromagneticcalorimeterforthehllhc |