A vacuum system for the thermal insulation of the SciFi distribution lines and manifolds

This note describes some calculations and estimates for the layout, technology choice and performance of a vacuum system which shall ensure thermal insulation of the distribution lines and manifolds of the SiPM cooling system of the LHCb SciFi detector. We estimate the heat losses in concentric corr...

Descripción completa

Detalles Bibliográficos
Autores principales: Joram, Christian, Pons, Xavier
Lenguaje:eng
Publicado: 2017
Materias:
Acceso en línea:http://cds.cern.ch/record/2295263
_version_ 1780956673539571712
author Joram, Christian
Pons, Xavier
author_facet Joram, Christian
Pons, Xavier
author_sort Joram, Christian
collection CERN
description This note describes some calculations and estimates for the layout, technology choice and performance of a vacuum system which shall ensure thermal insulation of the distribution lines and manifolds of the SiPM cooling system of the LHCb SciFi detector. We estimate the heat losses in concentric corrugated stainless steel pipes which leads to the conclusion that the pipes need to be evacuated to a pressure of about 1·10$^{-4}$ mbar. We then estimate the pumping conductance of the pipes and find that it will dominate over the effective pumping speed of any pump. We therefore conclude that a turbo molecular pump of small nominal pumping speed, which can easily achieve end pressures below 10$^{-5}$ mbar is adequate for this purpose. A preliminary layout of the vacuum system is being discussed at the end of the document.
id cern-2295263
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2017
record_format invenio
spelling cern-22952632019-09-30T06:29:59Zhttp://cds.cern.ch/record/2295263engJoram, ChristianPons, XavierA vacuum system for the thermal insulation of the SciFi distribution lines and manifoldsParticle Physics - ExperimentThis note describes some calculations and estimates for the layout, technology choice and performance of a vacuum system which shall ensure thermal insulation of the distribution lines and manifolds of the SiPM cooling system of the LHCb SciFi detector. We estimate the heat losses in concentric corrugated stainless steel pipes which leads to the conclusion that the pipes need to be evacuated to a pressure of about 1·10$^{-4}$ mbar. We then estimate the pumping conductance of the pipes and find that it will dominate over the effective pumping speed of any pump. We therefore conclude that a turbo molecular pump of small nominal pumping speed, which can easily achieve end pressures below 10$^{-5}$ mbar is adequate for this purpose. A preliminary layout of the vacuum system is being discussed at the end of the document.LHCb-PUB-2017-022CERN-LHCb-PUB-2017-022oai:cds.cern.ch:22952632017-12-04
spellingShingle Particle Physics - Experiment
Joram, Christian
Pons, Xavier
A vacuum system for the thermal insulation of the SciFi distribution lines and manifolds
title A vacuum system for the thermal insulation of the SciFi distribution lines and manifolds
title_full A vacuum system for the thermal insulation of the SciFi distribution lines and manifolds
title_fullStr A vacuum system for the thermal insulation of the SciFi distribution lines and manifolds
title_full_unstemmed A vacuum system for the thermal insulation of the SciFi distribution lines and manifolds
title_short A vacuum system for the thermal insulation of the SciFi distribution lines and manifolds
title_sort vacuum system for the thermal insulation of the scifi distribution lines and manifolds
topic Particle Physics - Experiment
url http://cds.cern.ch/record/2295263
work_keys_str_mv AT joramchristian avacuumsystemforthethermalinsulationofthescifidistributionlinesandmanifolds
AT ponsxavier avacuumsystemforthethermalinsulationofthescifidistributionlinesandmanifolds
AT joramchristian vacuumsystemforthethermalinsulationofthescifidistributionlinesandmanifolds
AT ponsxavier vacuumsystemforthethermalinsulationofthescifidistributionlinesandmanifolds