Cargando…

ReadMON: a portable readout system for the CERN PH-RADMON sensors

PH-RADMON sensors are extensively used for radiation monitoring in the LHC experiments. Here, ReadMON, a dedicated and portable readout system for non-LHC applications, is presented. The system is able to source currents up to 32 mA and measure voltages up to 125 V, covering the full operational ran...

Descripción completa

Detalles Bibliográficos
Autores principales: Mateu, Isidre, Glaser, Maurice, Gorine, Georgi, Moll, Michael, Pezzullo, Giuseppe, Ravotti, Federico
Formato: info:eu-repo/semantics/article
Lenguaje:eng
Publicado: IEEE Trans. Nucl. Sci. 2018
Materias:
Acceso en línea:https://dx.doi.org/10.1109/TNS.2017.2784684
http://cds.cern.ch/record/2302359
_version_ 1780957247510151168
author Mateu, Isidre
Glaser, Maurice
Gorine, Georgi
Moll, Michael
Pezzullo, Giuseppe
Ravotti, Federico
author_facet Mateu, Isidre
Glaser, Maurice
Gorine, Georgi
Moll, Michael
Pezzullo, Giuseppe
Ravotti, Federico
author_sort Mateu, Isidre
collection CERN
description PH-RADMON sensors are extensively used for radiation monitoring in the LHC experiments. Here, ReadMON, a dedicated and portable readout system for non-LHC applications, is presented. The system is able to source currents up to 32 mA and measure voltages up to 125 V, covering the full operational range of all dosimeters onboard the PH-RADMON sensor. Thus, the total measurement range of the system goes from 0.01 Gy to hundreds of kGy Total Ionizing Dose, and from few 10^10 neq/cm2 to 10^15 neq/cm2 1MeV neutron equivalent fluence. Different tests have been carried out at CERN IRRAD facility to prove the system concept and analyze its performance. Errors of only a few percent with respect to the readout done with a commercial Source Measuring Unit were found.
format info:eu-repo/semantics/article
id cern-2302359
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2018
publisher IEEE Trans. Nucl. Sci.
record_format invenio
spelling cern-23023592019-09-30T06:29:59Z doi:10.1109/TNS.2017.2784684 http://cds.cern.ch/record/2302359 eng Mateu, Isidre Glaser, Maurice Gorine, Georgi Moll, Michael Pezzullo, Giuseppe Ravotti, Federico ReadMON: a portable readout system for the CERN PH-RADMON sensors Detectors and Experimental Techniques 15: Upgrade of beam and irradiation test infrastructure PH-RADMON sensors are extensively used for radiation monitoring in the LHC experiments. Here, ReadMON, a dedicated and portable readout system for non-LHC applications, is presented. The system is able to source currents up to 32 mA and measure voltages up to 125 V, covering the full operational range of all dosimeters onboard the PH-RADMON sensor. Thus, the total measurement range of the system goes from 0.01 Gy to hundreds of kGy Total Ionizing Dose, and from few 10^10 neq/cm2 to 10^15 neq/cm2 1MeV neutron equivalent fluence. Different tests have been carried out at CERN IRRAD facility to prove the system concept and analyze its performance. Errors of only a few percent with respect to the readout done with a commercial Source Measuring Unit were found. info:eu-repo/grantAgreement/EC/FP7/654168 info:eu-repo/semantics/openAccess Education Level info:eu-repo/semantics/article http://cds.cern.ch/record/2302359 IEEE Trans. Nucl. Sci. IEEE Trans. Nucl. Sci., 8 (2018) pp. 1700-1707 2018
spellingShingle Detectors and Experimental Techniques
15: Upgrade of beam and irradiation test infrastructure
Mateu, Isidre
Glaser, Maurice
Gorine, Georgi
Moll, Michael
Pezzullo, Giuseppe
Ravotti, Federico
ReadMON: a portable readout system for the CERN PH-RADMON sensors
title ReadMON: a portable readout system for the CERN PH-RADMON sensors
title_full ReadMON: a portable readout system for the CERN PH-RADMON sensors
title_fullStr ReadMON: a portable readout system for the CERN PH-RADMON sensors
title_full_unstemmed ReadMON: a portable readout system for the CERN PH-RADMON sensors
title_short ReadMON: a portable readout system for the CERN PH-RADMON sensors
title_sort readmon: a portable readout system for the cern ph-radmon sensors
topic Detectors and Experimental Techniques
15: Upgrade of beam and irradiation test infrastructure
url https://dx.doi.org/10.1109/TNS.2017.2784684
http://cds.cern.ch/record/2302359
http://cds.cern.ch/record/2302359
work_keys_str_mv AT mateuisidre readmonaportablereadoutsystemforthecernphradmonsensors
AT glasermaurice readmonaportablereadoutsystemforthecernphradmonsensors
AT gorinegeorgi readmonaportablereadoutsystemforthecernphradmonsensors
AT mollmichael readmonaportablereadoutsystemforthecernphradmonsensors
AT pezzullogiuseppe readmonaportablereadoutsystemforthecernphradmonsensors
AT ravottifederico readmonaportablereadoutsystemforthecernphradmonsensors