PH-RADMON sensors are extensively used for radiation monitoring in the LHC experiments. Here, ReadMON, a dedicated and portable readout system for non-LHC applications, is presented. The system is able to source currents up to 32 mA and measure voltages up to 125 V, covering the full operational ran...
Autores principales: | , , , , , |
---|---|
Formato: | info:eu-repo/semantics/article |
Lenguaje: | eng |
Publicado: |
IEEE Trans. Nucl. Sci.
2018
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/TNS.2017.2784684 http://cds.cern.ch/record/2302359 |
_version_ | 1780957247510151168 |
---|---|
author | Mateu, Isidre Glaser, Maurice Gorine, Georgi Moll, Michael Pezzullo, Giuseppe Ravotti, Federico |
author_facet | Mateu, Isidre Glaser, Maurice Gorine, Georgi Moll, Michael Pezzullo, Giuseppe Ravotti, Federico |
author_sort | Mateu, Isidre |
collection | CERN |
description | PH-RADMON sensors are extensively used for radiation monitoring in the LHC experiments. Here, ReadMON, a dedicated and portable readout system for non-LHC applications, is presented. The system is able to source currents up to 32 mA and measure voltages up to 125 V, covering the full operational range of all dosimeters onboard the PH-RADMON sensor. Thus, the total measurement range of the system goes from 0.01 Gy to hundreds of kGy Total Ionizing Dose, and from few 10^10 neq/cm2 to 10^15 neq/cm2 1MeV neutron equivalent fluence. Different tests have been carried out at CERN IRRAD facility to prove the system concept and analyze its performance. Errors of only a few percent with respect to the readout done with a commercial Source Measuring Unit were found. |
format | info:eu-repo/semantics/article |
id | cern-2302359 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2018 |
publisher | IEEE Trans. Nucl. Sci. |
record_format | invenio |
spelling | cern-23023592019-09-30T06:29:59Z doi:10.1109/TNS.2017.2784684 http://cds.cern.ch/record/2302359 eng Mateu, Isidre Glaser, Maurice Gorine, Georgi Moll, Michael Pezzullo, Giuseppe Ravotti, Federico ReadMON: a portable readout system for the CERN PH-RADMON sensors Detectors and Experimental Techniques 15: Upgrade of beam and irradiation test infrastructure PH-RADMON sensors are extensively used for radiation monitoring in the LHC experiments. Here, ReadMON, a dedicated and portable readout system for non-LHC applications, is presented. The system is able to source currents up to 32 mA and measure voltages up to 125 V, covering the full operational range of all dosimeters onboard the PH-RADMON sensor. Thus, the total measurement range of the system goes from 0.01 Gy to hundreds of kGy Total Ionizing Dose, and from few 10^10 neq/cm2 to 10^15 neq/cm2 1MeV neutron equivalent fluence. Different tests have been carried out at CERN IRRAD facility to prove the system concept and analyze its performance. Errors of only a few percent with respect to the readout done with a commercial Source Measuring Unit were found. info:eu-repo/grantAgreement/EC/FP7/654168 info:eu-repo/semantics/openAccess Education Level info:eu-repo/semantics/article http://cds.cern.ch/record/2302359 IEEE Trans. Nucl. Sci. IEEE Trans. Nucl. Sci., 8 (2018) pp. 1700-1707 2018 |
spellingShingle | Detectors and Experimental Techniques 15: Upgrade of beam and irradiation test infrastructure Mateu, Isidre Glaser, Maurice Gorine, Georgi Moll, Michael Pezzullo, Giuseppe Ravotti, Federico ReadMON: a portable readout system for the CERN PH-RADMON sensors |
title | ReadMON: a portable readout system for the CERN PH-RADMON sensors |
title_full | ReadMON: a portable readout system for the CERN PH-RADMON sensors |
title_fullStr | ReadMON: a portable readout system for the CERN PH-RADMON sensors |
title_full_unstemmed | ReadMON: a portable readout system for the CERN PH-RADMON sensors |
title_short | ReadMON: a portable readout system for the CERN PH-RADMON sensors |
title_sort | readmon: a portable readout system for the cern ph-radmon sensors |
topic | Detectors and Experimental Techniques 15: Upgrade of beam and irradiation test infrastructure |
url | https://dx.doi.org/10.1109/TNS.2017.2784684 http://cds.cern.ch/record/2302359 http://cds.cern.ch/record/2302359 |
work_keys_str_mv | AT mateuisidre readmonaportablereadoutsystemforthecernphradmonsensors AT glasermaurice readmonaportablereadoutsystemforthecernphradmonsensors AT gorinegeorgi readmonaportablereadoutsystemforthecernphradmonsensors AT mollmichael readmonaportablereadoutsystemforthecernphradmonsensors AT pezzullogiuseppe readmonaportablereadoutsystemforthecernphradmonsensors AT ravottifederico readmonaportablereadoutsystemforthecernphradmonsensors |