Cargando…
The CMS ECAL Upgrade for Precision Crystal Calorimetry at the HL-LHC
The electromagnetic calorimeter (ECAL) of the Compact Muon Solenoid Experiment (CMS) is operating at the Large Hadron Collider (LHC) in 2016 with proton-proton collisions at 13 TeV center-of-mass energy and at a bunch spacing of 25 ns. Challenging running conditions for CMS are expected after the Hi...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2018
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1142/S2010194518600741 http://cds.cern.ch/record/2305549 |
_version_ | 1780957514940022784 |
---|---|
author | Petyt, David Anthony |
author_facet | Petyt, David Anthony |
author_sort | Petyt, David Anthony |
collection | CERN |
description | The electromagnetic calorimeter (ECAL) of the Compact Muon Solenoid Experiment (CMS) is operating at the Large Hadron Collider (LHC) in 2016 with proton-proton collisions at 13 TeV center-of-mass energy and at a bunch spacing of 25 ns. Challenging running conditions for CMS are expected after the High-Luminosity upgrade of the LHC (HL-LHC). We review the design and R and D studies for the CMS ECAL crystal calorimeter upgrade and present first test beam studies. Particular challenges at HL-LHC are the harsh radiation environment, the increasing data rates and the extreme level of pile-up events, with up to 200 simultaneous proton-proton collisions. We present test beam results of hadron irradiated PbWO$_{4}$ crystals up to fluences expected at the HL-LHC. We also report on the R and D for the new readout and trigger electronics, which must be upgraded due to the increased trigger and latency requirements at the HL-LHC. |
id | cern-2305549 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2018 |
record_format | invenio |
spelling | cern-23055492019-09-30T06:29:59Zdoi:10.1142/S2010194518600741http://cds.cern.ch/record/2305549engPetyt, David AnthonyThe CMS ECAL Upgrade for Precision Crystal Calorimetry at the HL-LHCDetectors and Experimental TechniquesThe electromagnetic calorimeter (ECAL) of the Compact Muon Solenoid Experiment (CMS) is operating at the Large Hadron Collider (LHC) in 2016 with proton-proton collisions at 13 TeV center-of-mass energy and at a bunch spacing of 25 ns. Challenging running conditions for CMS are expected after the High-Luminosity upgrade of the LHC (HL-LHC). We review the design and R and D studies for the CMS ECAL crystal calorimeter upgrade and present first test beam studies. Particular challenges at HL-LHC are the harsh radiation environment, the increasing data rates and the extreme level of pile-up events, with up to 200 simultaneous proton-proton collisions. We present test beam results of hadron irradiated PbWO$_{4}$ crystals up to fluences expected at the HL-LHC. We also report on the R and D for the new readout and trigger electronics, which must be upgraded due to the increased trigger and latency requirements at the HL-LHC.CMS-CR-2018-006oai:cds.cern.ch:23055492018-01-07 |
spellingShingle | Detectors and Experimental Techniques Petyt, David Anthony The CMS ECAL Upgrade for Precision Crystal Calorimetry at the HL-LHC |
title | The CMS ECAL Upgrade for Precision Crystal Calorimetry at the HL-LHC |
title_full | The CMS ECAL Upgrade for Precision Crystal Calorimetry at the HL-LHC |
title_fullStr | The CMS ECAL Upgrade for Precision Crystal Calorimetry at the HL-LHC |
title_full_unstemmed | The CMS ECAL Upgrade for Precision Crystal Calorimetry at the HL-LHC |
title_short | The CMS ECAL Upgrade for Precision Crystal Calorimetry at the HL-LHC |
title_sort | cms ecal upgrade for precision crystal calorimetry at the hl-lhc |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1142/S2010194518600741 http://cds.cern.ch/record/2305549 |
work_keys_str_mv | AT petytdavidanthony thecmsecalupgradeforprecisioncrystalcalorimetryatthehllhc AT petytdavidanthony cmsecalupgradeforprecisioncrystalcalorimetryatthehllhc |