Cargando…
Anode wire in cylindrical cathode tube : destabilizing electrostatic force
A two-dimensional -- cross-sectional -- discussion suffices. The tube is offset, and the electrostatic potential is found analytically with perturbative methods. Then, the force is established with the Maxwell stress tensor. Alternatively, trying to find the force with energy methods, fails. Finally...
Autor principal: | |
---|---|
Publicado: |
2017
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2305592 |
_version_ | 1780957516871499776 |
---|---|
author | Wertelaers, P |
author_facet | Wertelaers, P |
author_sort | Wertelaers, P |
collection | CERN |
description | A two-dimensional -- cross-sectional -- discussion suffices. The tube is offset, and the electrostatic potential is found analytically with perturbative methods. Then, the force is established with the Maxwell stress tensor. Alternatively, trying to find the force with energy methods, fails. Finally, finite element tests are performed in order to report on the degree of non-linearity for large offsets. |
id | cern-2305592 |
institution | Organización Europea para la Investigación Nuclear |
publishDate | 2017 |
record_format | invenio |
spelling | cern-23055922019-09-30T06:29:59Zhttp://cds.cern.ch/record/2305592Wertelaers, PAnode wire in cylindrical cathode tube : destabilizing electrostatic forceDetectors and Experimental TechniquesA two-dimensional -- cross-sectional -- discussion suffices. The tube is offset, and the electrostatic potential is found analytically with perturbative methods. Then, the force is established with the Maxwell stress tensor. Alternatively, trying to find the force with energy methods, fails. Finally, finite element tests are performed in order to report on the degree of non-linearity for large offsets.EP-Tech-Note-2018-003oai:cds.cern.ch:23055922017-05-01 |
spellingShingle | Detectors and Experimental Techniques Wertelaers, P Anode wire in cylindrical cathode tube : destabilizing electrostatic force |
title | Anode wire in cylindrical cathode tube : destabilizing electrostatic force |
title_full | Anode wire in cylindrical cathode tube : destabilizing electrostatic force |
title_fullStr | Anode wire in cylindrical cathode tube : destabilizing electrostatic force |
title_full_unstemmed | Anode wire in cylindrical cathode tube : destabilizing electrostatic force |
title_short | Anode wire in cylindrical cathode tube : destabilizing electrostatic force |
title_sort | anode wire in cylindrical cathode tube : destabilizing electrostatic force |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/2305592 |
work_keys_str_mv | AT wertelaersp anodewireincylindricalcathodetubedestabilizingelectrostaticforce |