Beam Transport Systems for Particle Therapy
The beam transport system between accelerator and patient treatment location in a particle therapy facility is described. After some general layout aspects the major beam handling tasks of this system are discussed. These are energy selection, an optimal transport of the particle beam to the beam de...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2017
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.23730/CYRSP-2017-001.241 http://cds.cern.ch/record/2315174 |
_version_ | 1780958122823647232 |
---|---|
author | Schippers, Jacobus Maarten |
author_facet | Schippers, Jacobus Maarten |
author_sort | Schippers, Jacobus Maarten |
collection | CERN |
description | The beam transport system between accelerator and patient treatment location in a particle therapy facility is described. After some general layout aspects the major beam handling tasks of this system are discussed. These are energy selection, an optimal transport of the particle beam to the beam delivery device and the gantry, a device that is able to rotate a beam delivery system around the patient, so that the tumour can be irradiated from almost any direction. Also the method of pencil beam scanning is described and how this is implemented within a gantry. Using this method the particle dose is spread over the tumour volume to the prescribed dose distribution. |
id | cern-2315174 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2017 |
record_format | invenio |
spelling | cern-23151742023-02-03T13:27:54Zdoi:10.23730/CYRSP-2017-001.241http://cds.cern.ch/record/2315174engSchippers, Jacobus MaartenBeam Transport Systems for Particle Therapyphysics.med-phHealth Physics and Radiation Effects The beam transport system between accelerator and patient treatment location in a particle therapy facility is described. After some general layout aspects the major beam handling tasks of this system are discussed. These are energy selection, an optimal transport of the particle beam to the beam delivery device and the gantry, a device that is able to rotate a beam delivery system around the patient, so that the tumour can be irradiated from almost any direction. Also the method of pencil beam scanning is described and how this is implemented within a gantry. Using this method the particle dose is spread over the tumour volume to the prescribed dose distribution.arXiv:1804.08551oai:cds.cern.ch:23151742017 |
spellingShingle | physics.med-ph Health Physics and Radiation Effects Schippers, Jacobus Maarten Beam Transport Systems for Particle Therapy |
title | Beam Transport Systems for Particle Therapy |
title_full | Beam Transport Systems for Particle Therapy |
title_fullStr | Beam Transport Systems for Particle Therapy |
title_full_unstemmed | Beam Transport Systems for Particle Therapy |
title_short | Beam Transport Systems for Particle Therapy |
title_sort | beam transport systems for particle therapy |
topic | physics.med-ph Health Physics and Radiation Effects |
url | https://dx.doi.org/10.23730/CYRSP-2017-001.241 http://cds.cern.ch/record/2315174 |
work_keys_str_mv | AT schippersjacobusmaarten beamtransportsystemsforparticletherapy |