Monte-Carlo based performance assessment of ASACUSA's antihydrogen detector
An antihydrogen detector consisting of a thin BGO disk and a surrounding plastic scintillator hodoscope has been developed. We have characterized the two-dimensional positions sensitivity of the thin BGO disk and energy deposition into the BGO was calibrated using cosmic rays by comparing experiment...
Autores principales: | , , , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2018
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2018.09.013 http://cds.cern.ch/record/2627655 |
_version_ | 1780959046348570624 |
---|---|
author | Nagata, Y. Kuroda, N. Kolbinger, B. Fleck, M. Malbrunot, C. Mäckel, V. Sauerzopf, C. Simon, M.C. Tajima, M. Zmeskal, J. Breuker, H. Higaki, H. Kanai, Y. Matsuda, Y. Ulmer, S. Venturelli, L. Widmann, E. Yamazaki, Y. |
author_facet | Nagata, Y. Kuroda, N. Kolbinger, B. Fleck, M. Malbrunot, C. Mäckel, V. Sauerzopf, C. Simon, M.C. Tajima, M. Zmeskal, J. Breuker, H. Higaki, H. Kanai, Y. Matsuda, Y. Ulmer, S. Venturelli, L. Widmann, E. Yamazaki, Y. |
author_sort | Nagata, Y. |
collection | CERN |
description | An antihydrogen detector consisting of a thin BGO disk and a surrounding plastic scintillator hodoscope has been developed. We have characterized the two-dimensional positions sensitivity of the thin BGO disk and energy deposition into the BGO was calibrated using cosmic rays by comparing experimental data with Monte-Carlo simulations. The particle tracks were defined by connecting BGO hit positions and hits on the surrounding hodoscope scintillator bars. The event rate was investigated as a function of the angles between the tracks and the energy deposition in the BGO for simulated antiproton events, and for measured and simulated cosmic ray events. Identification of the antihydrogen Monte Carlo events was performed using the energy deposited in the BGO and the particle tracks. The cosmic ray background was limited to 12 mHz with a detection efficiency of 81%. The signal-to-noise ratio was improved from 0.22 s−1∕2 obtained with the detector in 2012 to 0.26 s−1∕2 in this work. |
id | cern-2627655 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2018 |
record_format | invenio |
spelling | cern-26276552022-08-10T12:28:11Zdoi:10.1016/j.nima.2018.09.013http://cds.cern.ch/record/2627655engNagata, Y.Kuroda, N.Kolbinger, B.Fleck, M.Malbrunot, C.Mäckel, V.Sauerzopf, C.Simon, M.C.Tajima, M.Zmeskal, J.Breuker, H.Higaki, H.Kanai, Y.Matsuda, Y.Ulmer, S.Venturelli, L.Widmann, E.Yamazaki, Y.Monte-Carlo based performance assessment of ASACUSA's antihydrogen detectorphysics.ins-detDetectors and Experimental TechniquesAn antihydrogen detector consisting of a thin BGO disk and a surrounding plastic scintillator hodoscope has been developed. We have characterized the two-dimensional positions sensitivity of the thin BGO disk and energy deposition into the BGO was calibrated using cosmic rays by comparing experimental data with Monte-Carlo simulations. The particle tracks were defined by connecting BGO hit positions and hits on the surrounding hodoscope scintillator bars. The event rate was investigated as a function of the angles between the tracks and the energy deposition in the BGO for simulated antiproton events, and for measured and simulated cosmic ray events. Identification of the antihydrogen Monte Carlo events was performed using the energy deposited in the BGO and the particle tracks. The cosmic ray background was limited to 12 mHz with a detection efficiency of 81%. The signal-to-noise ratio was improved from 0.22 s−1∕2 obtained with the detector in 2012 to 0.26 s−1∕2 in this work.An antihydrogen detector consisting of a thin BGO disk and a surrounding plastic scintillator hodoscope has been developed. We have characterized the two-dimensional positions sensitivity of the thin BGO disk and energy deposition into the BGO was calibrated using cosmic rays by comparing experimental data with Monte-Carlo simulations. The particle tracks were defined by connecting BGO hit positions and hits on the surrounding hodoscope scintillator bars. The event rate was investigated as a function of the angles between the tracks and the energy deposition in the BGO for simulated antiproton events, and for measured and simulated cosmic ray events. Identification of the antihydrogen Monte Carlo events was performed using the energy deposited in the BGO and the particle tracks. The cosmic ray background was limited to 12 mHz with a detection efficiency of 81 %. The signal-to-noise ratio was improved from 0.22 s^{-1/2} obtained with the detector in 2012 to 0.26 s^{-1/2} in this work.arXiv:1806.00959oai:cds.cern.ch:26276552018-06-04 |
spellingShingle | physics.ins-det Detectors and Experimental Techniques Nagata, Y. Kuroda, N. Kolbinger, B. Fleck, M. Malbrunot, C. Mäckel, V. Sauerzopf, C. Simon, M.C. Tajima, M. Zmeskal, J. Breuker, H. Higaki, H. Kanai, Y. Matsuda, Y. Ulmer, S. Venturelli, L. Widmann, E. Yamazaki, Y. Monte-Carlo based performance assessment of ASACUSA's antihydrogen detector |
title | Monte-Carlo based performance assessment of ASACUSA's antihydrogen detector |
title_full | Monte-Carlo based performance assessment of ASACUSA's antihydrogen detector |
title_fullStr | Monte-Carlo based performance assessment of ASACUSA's antihydrogen detector |
title_full_unstemmed | Monte-Carlo based performance assessment of ASACUSA's antihydrogen detector |
title_short | Monte-Carlo based performance assessment of ASACUSA's antihydrogen detector |
title_sort | monte-carlo based performance assessment of asacusa's antihydrogen detector |
topic | physics.ins-det Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/j.nima.2018.09.013 http://cds.cern.ch/record/2627655 |
work_keys_str_mv | AT nagatay montecarlobasedperformanceassessmentofasacusasantihydrogendetector AT kurodan montecarlobasedperformanceassessmentofasacusasantihydrogendetector AT kolbingerb montecarlobasedperformanceassessmentofasacusasantihydrogendetector AT fleckm montecarlobasedperformanceassessmentofasacusasantihydrogendetector AT malbrunotc montecarlobasedperformanceassessmentofasacusasantihydrogendetector AT mackelv montecarlobasedperformanceassessmentofasacusasantihydrogendetector AT sauerzopfc montecarlobasedperformanceassessmentofasacusasantihydrogendetector AT simonmc montecarlobasedperformanceassessmentofasacusasantihydrogendetector AT tajimam montecarlobasedperformanceassessmentofasacusasantihydrogendetector AT zmeskalj montecarlobasedperformanceassessmentofasacusasantihydrogendetector AT breukerh montecarlobasedperformanceassessmentofasacusasantihydrogendetector AT higakih montecarlobasedperformanceassessmentofasacusasantihydrogendetector AT kanaiy montecarlobasedperformanceassessmentofasacusasantihydrogendetector AT matsuday montecarlobasedperformanceassessmentofasacusasantihydrogendetector AT ulmers montecarlobasedperformanceassessmentofasacusasantihydrogendetector AT venturellil montecarlobasedperformanceassessmentofasacusasantihydrogendetector AT widmanne montecarlobasedperformanceassessmentofasacusasantihydrogendetector AT yamazakiy montecarlobasedperformanceassessmentofasacusasantihydrogendetector |